Pelco CM9760-KBR Downloading Through the CM9760 System, Adjusting the Time-outPeriod

Models: CM9760-KBR

1 40
Download 40 pages 15.44 Kb
Page 16
Image 16
3.2.12.2 Downloading Through the CM9760 System

NOTE: Enter 0 to select all nodes, and enter 9999 to select the local node only.

The Keyboard LCD will indicate that it is cycling through the camera map settings; when finished, the LCD will display “End of Tx.”

3.2.12.2 Downloading Through the CM9760 System

Setups can be downloaded/uploaded using keyboards connected to 9760 systems. In this configuration, it is possible to upload the setup of a single keyboard to many other selected keyboards simultaneously. It is even possible to upload the setup of a single keyboard to all keyboards in a CCTV installation concurrently.

A CCTV installation may include multiple 9760 systems, each of which is referred to as a node. The nodes are designated numbers from 1 to 9998. To download/ upload keyboard setups through the 9760 system:

1.In keyboard setup mode, selectCM9760 using 3.2.13 Adjusting the Time-out Period and/or Manual background .

2.Using Manual background , select Node.

3.Select Manual background .

4.If necessary enter a node number in the range 1 to 9998.

5.Select Manual background once again.

6.Using Manual background select kbd#.

7.Select Manual background .

8.Enter a keyboard number in the range 1 to 96, or enter 0 to select all keyboards attached to selected node(s).

9.Select Manual background .

10.To download setup information from a connected keyboard, select Manual background or,

to upload setup information to a connected keyboard, select Manual background .

3.2.13 Adjusting the Time-out Period

ADVANCE SETUP 3

>AUTO LOGOFF (MIN) OFF AUTO CAM REL (MIN) 1 2015 ALM R (SEC) OFF

NOTE: The automatic log-off func- tion can be disabled by entering 0, 1, or 255.

The period of keyboard inactivity which invokes the automatic log-off function can be modified. Operators may be timed out after periods of inactivity ranging from 1 to 254 minutes. To specify a time-out period:

1.Select Manual background from the setup mode menu.

2.Go to Advance Setup 3 using Manual background and/or Manual background .

3.To enter a time-out period, select Manual background , and type a duration between 2 and 254 (minutes).

4.Select Manual background once again.

5.Select Manual background .

6.Select Manual background .

16

Pelco Manual C540M (6/98)

Page 16
Image 16
Pelco CM9760-KBR Downloading Through the CM9760 System, Adjusting the Time-outPeriod, Pelco Manual C540M 6/98