Roberts Gorden 10081601NA Rev H 12/11 service manual Ultravac Controller Label Placement

Page 10

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL

FIGURE 1: ULTRAVAC™ Controller Label Placement

Light Label

Electrical Shock Hazard Label

Logo Label Rating Plate Label Front Door Panel (outside)

External Wiring Label

NC

C NO

NC

C NO

NC

C NO

NC

C NO

L2 L1

PWR

OUT IN

G

+32 +5 G

G

G

REF

-

+

REF

-

+

-

+

-

+

-

+

-

+

 

 

 

 

 

 

 

 

24VAC

 

RS232 DIRECT

 

 

 

 

OUT

 

 

IN

 

 

4

 

3

 

2

 

1

 

 

 

 

 

 

 

 

 

 

 

AUX POWER

 

 

RS485 COMM

 

 

 

METER INPUTS

 

 

RESET

 

OH CD

RI

ADDRESS

 

CPU

 

 

 

8

 

7

6

UNIVERSAL INPUTS

 

3

 

2

 

1

NC C NO NC C NO NC C NO NC C NO

 

 

 

 

5

 

4

 

 

 

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

499 OHM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10VDC

Front Door Panel (inside)

 

Description

Part Number

 

Logo Label

91013207

 

Rating Plate Label

91008005

 

Light Label

91008007

Control Board Wiring Label

Control Board Wiring Label

91008004

 

External Wiring Label

91008003

 

Shock Hazard label

91008001

4 of 62

Image 10
Contents UltraVac Page Roberts-Gordon LLC Page Table of Figures Page Page What is Roberts Gordon ULTRAVAC? Introduction 1.1 SafetyCorayvac Design Requirements Example Site Layout Check Installation Materials 1.6.1 Switchable LoadsSafety Labels and Their Placement Programming DetailsUltravac Controller Label Placement Ultravac BMS Link Controller Label Placement VFD Label Placement Repeater Label Placement Connected Components Connected Components Carton Contents Urvsc Ultravac Satellite Controller Urvccm Ultravac Central Controller with Modem Urvccr Ultravac Central Controller with RS-485 Converter Standard Parts List Urvbnc Ultravac BMS Link ControllerCommon Components of Roberts Gordon Ultravac Controls Example Site Layout Specifications Line Reactor 480 V / 4 a Output Nema 4 Enclosure for Indoor Sensor P/NVoltage Surge Suppressor 277 / 480 Line Reactor 480 V / 4 a InputRoberts Gordon Ultravac Controller Specifications Variable Frequency Drive VFD 2.7.1 Enclosure Standard Models Nema 4 ModelsVariable Frequency Drive Components Factory pre-wiring shown Preparation InstallationVFD should be mounted in locations where Ultravac BMS Link Controller Cable RequirementsUltravac Controller Variable Frequency Drive VFDPump Requirements Variable Frequency Drive RequirementsOutdoor Sensor Placement Indoor Sensor PlacementOutside Air Supply Typical External Diagrams Roberts Gordon Ultravac Central Controller External Wiring Roberts Gordon Ultravac Central Controller External Wiring Roberts Gordon Ultravac Satellite Controller External Wiring Roberts Gordon Ultravac Satellite Controller External Wiring Communications Dedicated Phone Line for Central Controller ModemRS-485 Converter for Central Controller RS-485 PC ConnectionTCP/IP Communication Module TCP/IP Communication Module MountingTCP/IP Communication Module Wiring Direct ConnectPin Adapter for PC Communications Between Multiple Controllers Repeater External Wiring Repeater Communication Wiring Between Multiple Controllers Ultravac BMS Link Controller Ultravac BMS Link Controller OverviewUltravac BMS Link Controller Technical Data Ultravac BMS Link Controller ProgrammingUltravac BMS Link Controller Variable Frequency Drive Programming VFD Parameter Settings For Use WithRoberts Gordon Ultravac Parameter Factory New Number Name Default Altering VFD ParametersSetting The Corayvac End Burner Vacuum Commissioning the Corayvac SystemEnd Vent Vacuum Possible Damper Couplings’ Locations Parameter Factory New Number Name Default Troubleshooting Electrical Shock Hazard Disconnect electric before serviceTroubleshooting Flow Chart Troubleshooting Flow Chart Troubleshooting Flow Chart Troubleshooting Flow Chart Troubleshooting Flow Chart Repeater Troubleshooting Flow Chart BACnet Replacement Parts Roberts Gordon Ultravac Controller Replacement Parts Roberts Gordon Ultravac Controller Components DiagramVariable Frequency Drive Replacement Parts Variable Frequency Drive Components DiagramUltravac BMS Link Controller Replacement Parts Ultravac BMS Link Controller Components DiagramRepeater Replacement Parts Repeater Components Diagram10.5.3 10080122 Eprom Chip Control Board Power LED10.5.4 24V Power 1 a Fuse Variable Frequency Drive 25 a or 10 a FuseReplacement Parts ROBERTS-GORDON will not PAY for Roberts Gordon Ultravac Limited WarrantyWarranty is Void if Limitations on Authority Representatives

10081601NA Rev H 12/11 specifications

Roberts Gorden is known for manufacturing high-quality heating systems, and one of their standout products is the model 10081601NA Rev H from December 2011. This unit exemplifies reliable performance and innovative technology, making it a popular choice in various industrial and commercial applications.

The Roberts Gorden 10081601NA Rev H is designed with efficiency in mind. One of its main features is the advanced infrared heating technology that ensures uniform heat distribution across large spaces. This is particularly beneficial in environments with high ceilings or open layouts, where traditional heating methods may struggle to maintain consistent temperatures. The infrared system allows for energy savings, as it heats objects and people directly rather than wasting energy on heating the air.

Another notable characteristic of the 10081601NA Rev H is its robust construction. Built to withstand rigorous operational environments, it often includes durable materials that enhance longevity and reliability. This product typically features corrosion-resistant components, making it suitable for use in various settings, including warehouses, manufacturing plants, and other commercial facilities.

The unit is also designed with user-friendly controls that allow for easy temperature adjustments and monitoring of performance. Advanced digital control systems may be integrated, providing precise control over heating levels. This feature ensures that users can tailor the heating output to their specific needs, optimizing energy consumption and comfort.

Safety is a priority with the Roberts Gorden 10081601NA Rev H, as it usually comes equipped with multiple safety features. These may include flame detection systems, automatic shutoff capabilities, and user alerts for maintenance requirements. Such features help ensure not only the efficiency of the heating system but also the safety of the personnel operating in the vicinity.

In summary, the Roberts Gorden 10081601NA Rev H is a cutting-edge heating solution that combines efficiency, durability, ease of use, and safety. Its main features, such as advanced infrared technology, robust construction, user-friendly controls, and safety mechanisms, make it an ideal choice for industries that demand reliable and effective heating solutions. Whether in a manufacturing setup or a large commercial space, this model stands out as a leading heating technology.