Roberts Gorden 10081601NA Rev H 12/11 Roberts Gordon Ultravac Controller Replacement Parts

Page 62

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL

10.1 ROBERTS GORDON® ULTRAVAC™ Controller Replacement Parts

Caution: Use only genuine ROBERTS GORDON® replacement parts. Use of parts not specified by Roberts-Gordon voids warranty.

FIGURE 31: ROBERTS GORDON® ULTRAVAC™ Controller Components Diagram

 

GRD L2

L1

 

8 OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRD L2

L1

GRD L2

 

L1

GRD L2

L1

GRD L2

L1

7 OUTPUT

 

6 OUTPUT

5 OUTPUT

4 OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plug-In

Relays

GRD L2

L1 GRD L2

L1 GRD L2

L1 GRD L2

L1

3 OUTPUT

2 OUTPUT

1 OUTPUT

POWER

 

24 V

Power

1 A Fuse

24 V

Power

Switch

Relay

Board

NC C NO NC C NO

NC C NO NC C NO

L2 L1 PWR

24VAC

Reset

Button

OUT IN

G

+32 +5 G

G

G

REF

-

+

REF

-

+

-

+

-

+

-

+

-

+

RS232 DIRECT

 

 

 

 

OUT

 

 

IN

 

 

4

 

3

 

2

 

1

 

AUX POWER

 

 

RS485 COMM

 

 

 

METER INPUTS

 

 

RESET

OH CD RI

ADDRESS

Control Board

NC C NO

NC C NO

NC C NO NC C NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPU

 

 

8

 

7

6

UNIVERSAL INPUTS

 

3

 

2

 

1

 

 

 

 

 

 

5

 

4

 

 

 

 

 

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

OUT

499 OHM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

10VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modem Chip

(only located on

Central Controller)

Analog

Output

Board

Description

Part Number

Control Board (150 style)

10080102

Relay Board

10080200

 

10080141

Analog Output Board

URV Eprom Chip (150 Style, current version)

10080122

 

10080212

Plug-In Relay

Modem Chip (located only on central controller)

10080142

 

10080211

1 A Fuse (Relay Board)

ROBERTS GORDON® ULTRAVAC™ Indoor Sensor °F (not shown)

10081500

 

10081501

ROBERTS GORDON® ULTRAVAC™ Outdoor Sensor (not shown)

ROBERTS GORDON® ULTRAVAC™ Indoor Sensor °C (not shown)

10081502

 

10080410

PC Connection Cable Package (not shown)

RS-485 Converter Package (not shown)

10080430

 

10080440K

Kit, TCP/IP Communication Module (not shown)

Telephone Sharing Device, 4 port

10080600

 

 

56 of 62

Image 62
Contents UltraVac Page Roberts-Gordon LLC Page Table of Figures Page Page Corayvac Design Requirements Introduction 1.1 SafetyWhat is Roberts Gordon ULTRAVAC? Example Site Layout Check Installation Materials 1.6.1 Switchable LoadsSafety Labels and Their Placement Programming DetailsUltravac Controller Label Placement Ultravac BMS Link Controller Label Placement VFD Label Placement Repeater Label Placement Connected Components Connected Components Carton Contents Urvsc Ultravac Satellite Controller Urvccm Ultravac Central Controller with Modem Urvccr Ultravac Central Controller with RS-485 Converter Standard Parts List Urvbnc Ultravac BMS Link ControllerCommon Components of Roberts Gordon Ultravac Controls Example Site Layout Specifications Line Reactor 480 V / 4 a Output Nema 4 Enclosure for Indoor Sensor P/NVoltage Surge Suppressor 277 / 480 Line Reactor 480 V / 4 a InputRoberts Gordon Ultravac Controller Specifications Variable Frequency Drive VFD 2.7.1 Enclosure Standard Models Nema 4 ModelsVariable Frequency Drive Components Factory pre-wiring shown VFD should be mounted in locations where InstallationPreparation Ultravac BMS Link Controller Cable RequirementsUltravac Controller Variable Frequency Drive VFDPump Requirements Variable Frequency Drive RequirementsOutside Air Supply Indoor Sensor PlacementOutdoor Sensor Placement Typical External Diagrams Roberts Gordon Ultravac Central Controller External Wiring Roberts Gordon Ultravac Central Controller External Wiring Roberts Gordon Ultravac Satellite Controller External Wiring Roberts Gordon Ultravac Satellite Controller External Wiring Communications Dedicated Phone Line for Central Controller ModemRS-485 Converter for Central Controller RS-485 PC ConnectionTCP/IP Communication Module TCP/IP Communication Module MountingTCP/IP Communication Module Wiring Direct ConnectPin Adapter for PC Communications Between Multiple Controllers Repeater External Wiring Repeater Communication Wiring Between Multiple Controllers Ultravac BMS Link Controller Ultravac BMS Link Controller OverviewUltravac BMS Link Controller Technical Data Ultravac BMS Link Controller ProgrammingUltravac BMS Link Controller Roberts Gordon Ultravac VFD Parameter Settings For Use WithVariable Frequency Drive Programming Parameter Factory New Number Name Default Altering VFD ParametersSetting The Corayvac End Burner Vacuum Commissioning the Corayvac SystemEnd Vent Vacuum Possible Damper Couplings’ Locations Parameter Factory New Number Name Default Troubleshooting Electrical Shock Hazard Disconnect electric before serviceTroubleshooting Flow Chart Troubleshooting Flow Chart Troubleshooting Flow Chart Troubleshooting Flow Chart Troubleshooting Flow Chart Repeater Troubleshooting Flow Chart BACnet Replacement Parts Roberts Gordon Ultravac Controller Replacement Parts Roberts Gordon Ultravac Controller Components DiagramVariable Frequency Drive Replacement Parts Variable Frequency Drive Components DiagramUltravac BMS Link Controller Replacement Parts Ultravac BMS Link Controller Components DiagramRepeater Replacement Parts Repeater Components Diagram10.5.3 10080122 Eprom Chip Control Board Power LED10.5.4 24V Power 1 a Fuse Variable Frequency Drive 25 a or 10 a FuseReplacement Parts ROBERTS-GORDON will not PAY for Roberts Gordon Ultravac Limited WarrantyWarranty is Void if Limitations on Authority Representatives

10081601NA Rev H 12/11 specifications

Roberts Gorden is known for manufacturing high-quality heating systems, and one of their standout products is the model 10081601NA Rev H from December 2011. This unit exemplifies reliable performance and innovative technology, making it a popular choice in various industrial and commercial applications.

The Roberts Gorden 10081601NA Rev H is designed with efficiency in mind. One of its main features is the advanced infrared heating technology that ensures uniform heat distribution across large spaces. This is particularly beneficial in environments with high ceilings or open layouts, where traditional heating methods may struggle to maintain consistent temperatures. The infrared system allows for energy savings, as it heats objects and people directly rather than wasting energy on heating the air.

Another notable characteristic of the 10081601NA Rev H is its robust construction. Built to withstand rigorous operational environments, it often includes durable materials that enhance longevity and reliability. This product typically features corrosion-resistant components, making it suitable for use in various settings, including warehouses, manufacturing plants, and other commercial facilities.

The unit is also designed with user-friendly controls that allow for easy temperature adjustments and monitoring of performance. Advanced digital control systems may be integrated, providing precise control over heating levels. This feature ensures that users can tailor the heating output to their specific needs, optimizing energy consumption and comfort.

Safety is a priority with the Roberts Gorden 10081601NA Rev H, as it usually comes equipped with multiple safety features. These may include flame detection systems, automatic shutoff capabilities, and user alerts for maintenance requirements. Such features help ensure not only the efficiency of the heating system but also the safety of the personnel operating in the vicinity.

In summary, the Roberts Gorden 10081601NA Rev H is a cutting-edge heating solution that combines efficiency, durability, ease of use, and safety. Its main features, such as advanced infrared technology, robust construction, user-friendly controls, and safety mechanisms, make it an ideal choice for industries that demand reliable and effective heating solutions. Whether in a manufacturing setup or a large commercial space, this model stands out as a leading heating technology.