Roberts Gorden 10081601NA Rev H 12/11 service manual Variable Frequency Drive Programming

Page 48

ROBERTS GORDON® ULTRAVAC™ CONTROLLER INSTALLATION MANUAL

SECTION 7: VARIABLE FREQUENCY DRIVE PROGRAMMING

7.1VFD Parameter Settings For Use With

ROBERTS GORDON® ULTRAVAC™

The VFD parameters come with factory default set- tings. The following parameter settings must be changed for ROBERTS GORDON® ULTRAVAC™. Settings can only be altered when the pump motor is stopped.

Verify that there is power to the VFD (LCD display will be on) and no power to the 24 V power switch on the relay board of the ROBERTS GORDON® ULTRAVAC™.

DANGER

Electrical Shock Hazard

Enclosure contains live electrical components.

Programming must be done by a trained technician only.

Replace cover before operating.

Failure to follow these instructions can result in death or electrical shock.

To override the rotary disconnect switch inside the VFD enclosure, turn the square rod with a wrench to the ON position. In order to be able to close the cover of the disconnect, the rods need to be turned back to the OFF position.

7.1.2

Use the arrow buttons to scroll to the password value (the factory set password is 225).

Press Mode to enter password.

Once the correct password value is entered, the dis- play will read "P01", which indicates that the PROGRAM mode has been accessed at the begin- ning of the parameter menu (P01 is the first parameter).

2 25

P 01

NOTE: If the display flashes "Er", the password was incorrect, and the process to enter the password must be repeated.

7.1.3Use the arrow buttons to scroll to the desired parameter number. For new parameter settings, See Page 43, Section 7.2.

7.1.4Once the desired parameter number is found:

Press Mode to display present parameter setting (example setting is 20.0).

Upper right decimal point blinks.

7.1.1

To enter the PROGRAM mode and access the parameters, press the Mode button. This will activate the PASSWORD prompt (if the password has not been disabled).

Display reads "00"

Upper right decimal point blinks

00

Use arrow buttons to change setting.

Press Mode to store new setting and exit the program mode.

7.1.5To change another parameter, press the Mode key again to re-enter the PROGRAM mode (the parameter menu will be accessed at the parameter that was last viewed or changed before exiting).

If the Mode key is pressed within two minutes of exit- ing the PROGRAM mode, the password is not required to access the parameters. After two minutes,

42 of 62

Image 48
Contents UltraVac Page Roberts-Gordon LLC Page Table of Figures Page Page Introduction 1.1 Safety What is Roberts Gordon ULTRAVAC?Corayvac Design Requirements Check Installation Materials 1.6.1 Switchable Loads Safety Labels and Their PlacementExample Site Layout Programming DetailsUltravac Controller Label Placement Ultravac BMS Link Controller Label Placement VFD Label Placement Repeater Label Placement Connected Components Connected Components Carton Contents Urvsc Ultravac Satellite Controller Urvccm Ultravac Central Controller with Modem Urvccr Ultravac Central Controller with RS-485 Converter Standard Parts List Urvbnc Ultravac BMS Link ControllerCommon Components of Roberts Gordon Ultravac Controls Example Site Layout Specifications Nema 4 Enclosure for Indoor Sensor P/N Voltage Surge Suppressor 277 / 480Line Reactor 480 V / 4 a Output Line Reactor 480 V / 4 a InputRoberts Gordon Ultravac Controller Specifications Variable Frequency Drive VFD 2.7.1 Enclosure Standard Models Nema 4 ModelsVariable Frequency Drive Components Factory pre-wiring shown Installation PreparationVFD should be mounted in locations where Cable Requirements Ultravac ControllerUltravac BMS Link Controller Variable Frequency Drive VFDPump Requirements Variable Frequency Drive RequirementsIndoor Sensor Placement Outdoor Sensor PlacementOutside Air Supply Typical External Diagrams Roberts Gordon Ultravac Central Controller External Wiring Roberts Gordon Ultravac Central Controller External Wiring Roberts Gordon Ultravac Satellite Controller External Wiring Roberts Gordon Ultravac Satellite Controller External Wiring Communications Dedicated Phone Line for Central Controller ModemRS-485 Converter for Central Controller RS-485 PC ConnectionTCP/IP Communication Module TCP/IP Communication Module MountingTCP/IP Communication Module Wiring Direct ConnectPin Adapter for PC Communications Between Multiple Controllers Repeater External Wiring Repeater Communication Wiring Between Multiple Controllers Ultravac BMS Link Controller Ultravac BMS Link Controller OverviewUltravac BMS Link Controller Technical Data Ultravac BMS Link Controller ProgrammingUltravac BMS Link Controller VFD Parameter Settings For Use With Variable Frequency Drive ProgrammingRoberts Gordon Ultravac Parameter Factory New Number Name Default Altering VFD ParametersSetting The Corayvac End Burner Vacuum Commissioning the Corayvac SystemEnd Vent Vacuum Possible Damper Couplings’ Locations Parameter Factory New Number Name Default Troubleshooting Electrical Shock Hazard Disconnect electric before serviceTroubleshooting Flow Chart Troubleshooting Flow Chart Troubleshooting Flow Chart Troubleshooting Flow Chart Troubleshooting Flow Chart Repeater Troubleshooting Flow Chart BACnet Replacement Parts Roberts Gordon Ultravac Controller Replacement Parts Roberts Gordon Ultravac Controller Components DiagramVariable Frequency Drive Replacement Parts Variable Frequency Drive Components DiagramUltravac BMS Link Controller Replacement Parts Ultravac BMS Link Controller Components DiagramRepeater Replacement Parts Repeater Components DiagramControl Board Power LED 10.5.4 24V Power 1 a Fuse10.5.3 10080122 Eprom Chip Variable Frequency Drive 25 a or 10 a FuseReplacement Parts Roberts Gordon Ultravac Limited Warranty Warranty is Void ifROBERTS-GORDON will not PAY for Limitations on Authority Representatives

10081601NA Rev H 12/11 specifications

Roberts Gorden is known for manufacturing high-quality heating systems, and one of their standout products is the model 10081601NA Rev H from December 2011. This unit exemplifies reliable performance and innovative technology, making it a popular choice in various industrial and commercial applications.

The Roberts Gorden 10081601NA Rev H is designed with efficiency in mind. One of its main features is the advanced infrared heating technology that ensures uniform heat distribution across large spaces. This is particularly beneficial in environments with high ceilings or open layouts, where traditional heating methods may struggle to maintain consistent temperatures. The infrared system allows for energy savings, as it heats objects and people directly rather than wasting energy on heating the air.

Another notable characteristic of the 10081601NA Rev H is its robust construction. Built to withstand rigorous operational environments, it often includes durable materials that enhance longevity and reliability. This product typically features corrosion-resistant components, making it suitable for use in various settings, including warehouses, manufacturing plants, and other commercial facilities.

The unit is also designed with user-friendly controls that allow for easy temperature adjustments and monitoring of performance. Advanced digital control systems may be integrated, providing precise control over heating levels. This feature ensures that users can tailor the heating output to their specific needs, optimizing energy consumption and comfort.

Safety is a priority with the Roberts Gorden 10081601NA Rev H, as it usually comes equipped with multiple safety features. These may include flame detection systems, automatic shutoff capabilities, and user alerts for maintenance requirements. Such features help ensure not only the efficiency of the heating system but also the safety of the personnel operating in the vicinity.

In summary, the Roberts Gorden 10081601NA Rev H is a cutting-edge heating solution that combines efficiency, durability, ease of use, and safety. Its main features, such as advanced infrared technology, robust construction, user-friendly controls, and safety mechanisms, make it an ideal choice for industries that demand reliable and effective heating solutions. Whether in a manufacturing setup or a large commercial space, this model stands out as a leading heating technology.