Heat & Glo LifeStyle BAY-40 owner manual Construct the Chase, Chimney Requirements

Page 12

E. Construct the Chase

A chase is a vertical boxlike structure built to enclose the fire- place and/or its vent system. Vertical chimneys that run on the outside of a building must be installed inside a chase.

Construction of the chase may vary with the type of build- ing. These instructions are not substitutes for the require- ments of local building codes. Local building codes MUST be checked.

Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside building envelope in any manner. All outer walls need to be insulated.

Building codes require false ceiling and ceiling firestops at each floor of the chase or every 10 ft (3.05 m) of clear space to control spread of fire.

Walls, ceiling, base plate and cantilever floor at the first level of the chase should be insulated. See Figure 3.5. Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, Hearth

&Home Technologies recommends that the inside surfac- es be sheet rocked and taped (or the use of an equivalent method) for maximum air tightness.

Round Termination Cap

Metal Chase Top

Ceiling

Firestop

False Ceiling

Figure 3.5

Chase Assembly

Gas line holes and other openings should be caulked with high temperature caulk or stuffed with unfaced fiberglass in- sulation. If the fireplace is being installed on a cement slab, we recommend that in cold climates, a sheet of plywood or other raised platform be placed underneath to prevent con- ducting cold up into the room.

Three examples of chase applications are shown in Fig- ure 3.6.

1.Fireplace and chimney enclosed in an exterior chase.

2.Chimney offset through exterior wall and enclosed in chase.

3.Chase constructed on roof.

12

Figure 3.6 Chase Constructions

F. Chimney Requirements

When planning your fireplace location, the chimney con- struction and necessary clearances must be considered. The fireplace system and chimney components have been tested to provide flexibility in construction. Vertical distances are measured from the base of the fireplace as shown in Figure 5.2.

Minimum overall straight height

14

(4.27 m)

Minimum height with offset/return

16.5 ft

(5.03 m)

• Maximum height

90 ft

(27.43 m)

• Maximum chimney length between an offset

20 ft

(6.1 m)

 

and return

 

 

• Maximum distance between chimney

35 ft

(10.67 m)

 

stabilizers

 

 

Double offset/return minimum height

20 ft

(6.1 m)

• Maximum unsupported chimney length

6 ft

(1.83 m)

 

between the offset and return

 

 

• Maximum unsupported chimney height above

35 ft

(10.67 m)

 

the fireplace

 

 

• Maximum unsupported chimney above roof

6 ft

(1.83 m)

Note: A maximum of two pairs of offsets and returns may be used.

12

Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07

Image 12
Contents Hot glass will cause burns Fire RiskListing Label Information/Location GrateNumber Table of Contents Listing and Code Approvals Appliance CertificationNot intended for use as a primary heat source Design and Installation Considerations Getting StartedNegative Pressure Asphyxiation RiskMarginal Location Typical Fireplace System Typical Fireplace SystemTools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Framing and Clearances Selecting Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceConstruct the Chase Chimney RequirementsInstallation of Fireplace Install the Outside Air KitSharp Edges Asphyxiation Risk Risk of Smoke SpillageFt min. from top of uppermost chimney section to air inlet Secure the Fireplace Position the FireplacePlace the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Height of Chimney Components Using Offsets/Returns SL1106 SL1112 SL1118 SL1136 SL1148Install the Ceiling Firestops Assemble the Chimney Sections¨E. Install the Attic Insulation Shield Away from chimney pipe may cause fireDouble-check the Chimney Assembly Secure the ChimneyComplete the Enclosure Chimney TerminationChimney Termination Requirements See Figures 6.1 Install the Roof Flashing Install the Chimney Air Kit required in CanadaMark the Exit Point of the Roof ¨ Cut Out the Hole in the RoofInstall the Termination Cap Chase TopInstalling an ST1175 Square Termination Cap Accessories Gas Log/Lighter ProvisionsGas Code, Ansi Z223.1 Finishing Hearth Extension¨ Table Finishing Material Combustible MaterialNon-Combustible Material Mantel Glass DoorsOperating Instructions General InformationOutside Air Clear Space Near the FireplaceFlue Damper FirescreenGrate Wood FuelFirewood MoistureStarting a Fire Troubleshooting Understanding Vent ProblemsDiagnostics and Problem Solving Diagnostic QuestionsSolutions Can’t get a good fire going. What am I doing wrong?fireplace burns the wood too fast. What can I do? Maintenance and Servicing the Fireplace Chimney Inspection/CleaningDisposal of Ashes Firebox RefractoryMaintenance Task List When cleaning glass doorClean Chimney FireFireplace Dimensions Reference MaterialsFireplace Components Catalog # DescriptionChimney Components Catalog #14-1/2 15-3/4 400 mm European Copper Caps Minimum Base Dimensions 28 X 28 with 32 X 32 with 23 X Minimum Base Dimensions 26.5 X 28 with 34 X 34 withTR442 TR442 / 444 TV 20 xService Parts BAY-40Description of Part Part Number Qty.req GR3PIER-40 # Description of Part QtyThis page intentionally left blank Warranty For Heat & GLO Fireplaces Limited WarrantyDo not Discard this Manual

BAY-40 specifications

The Heat & Glo LifeStyle BAY-40 is a modern gas fireplace designed to deliver both style and functionality while enhancing the ambiance of any living space. Touted for its sleek design and advanced features, the BAY-40 serves as a centerpiece that combines warmth with contemporary aesthetics.

One of the most notable aspects of the LifeStyle BAY-40 is its impressive heat output, ensuring that rooms remain cozy even in the coldest months. With a variety of heat settings, users can easily adjust the temperature to their comfort level. This versatility makes it an ideal option for any home, whether for an expansive living area or a more compact setting.

The BAY-40 is equipped with an innovative IntelliFire technology that promotes ease of use and safety. This advanced ignition system eliminates the need for manual lighting, allowing users to start their fire at the push of a button. Additionally, the remote control feature offers convenience, enabling homeowners to control the fireplace from across the room, adding to the overall comfort factor.

Aesthetically, the LifeStyle BAY-40 is designed with a contemporary look in mind. Its large viewing area provides an unobstructed view of the flames, creating a warm and inviting atmosphere. The unique bay design not only enhances the visual appeal but also allows for a wider flame presentation, adding to the overall warmth of the room.

The fireplace also offers customizable options, such as different interior finishes and decorative media like glass or logs. These choices allow homeowners to tailor the fireplace to match their existing décor, contributing to a cohesive design throughout their home.

Moreover, the BAY-40 incorporates advanced safety features such as an automatic shut-off mechanism that activates in case of malfunction, ensuring peace of mind for users.

In summary, the Heat & Glo LifeStyle BAY-40 is more than just a fireplace; it’s a blend of innovation, design, and efficiency. Whether you are seeking to enhance your living space or provide warmth to your home, the BAY-40 stands out as an exceptional choice that balances modern technology with elegant aesthetics. Its range of features ensures both comfort and safety, making it a prime addition to any home.