Heat & Glo LifeStyle BAY-40 owner manual Using Offsets/Returns, SL1106 SL1112 SL1118 SL1136 SL1148

Page 18

B. Using Offsets/Returns

To bypass any overhead obstructions, the chimney may be offset using an offset/return.

An offset and return may be attached together or a chimney section(s) may be used between an offset and return.

Perform the following steps to determine the correct chim- ney component combination for your particular installation:

WARNING

Fire Risk

Draft will be restricted if offset/returns greater than 30° are used.

Measure how far the chimney needs to be shifted to enable it to avoid the overhead obstacle. See Figure 5.3. Use dimension “A” to determine chimney section required to achieve the needed shift.

After determining the offset dimension, refer to Table 5.2 and find the “A” dimension closest to but not less than the distance of shift needed for your installation.

The “B” dimension that coincides with the “A” dimension represents the required vertical clearance that is needed to complete the offset and return.

Read across the chart and find the number of chimney sections required and the model number of those particular chimney parts.

Whenever the chimney penetrates a floor/ceiling, a ceiling firestop must be installed.

The effective height of the fireplace assembly is measured from the base of the fireplace to the top of the starter collar. See Dimensions in Section 12.

Table 5.2

 

A

 

B

 

 

 

 

 

in.

 

mm

in.

 

mm

SL1106

SL1112

SL1118

SL1136

SL1148

4 7/8

 

124

17 7/8

 

454

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

7 1/4

 

184

22

 

559

1

-

-

-

-

9 3/4

 

248

26 1/8

 

664

2

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

10 1/4

 

260

27 1/4

 

692

-

1

-

-

-

12 3/4

 

324

31 3/8

 

797

1

1

-

-

-

13 1/4

 

337

32 3/8

 

822

-

-

1

-

-

15 3/4

 

400

36 5/8

 

930

-

2

-

-

-

18 1/8

 

460

40 3/4

 

1035

1

2

-

-

-

 

 

 

 

 

 

 

 

 

 

 

18 3/4

 

476

41 3/4

 

1060

-

1

1

-

-

21 3/4

 

552

47

 

1194

-

-

2

-

-

 

 

 

 

 

 

 

 

 

 

 

22 1/4

 

565

4 8

 

1219

-

-

-

1

-

24 3/4

 

629

52 1/8

 

1324

1

-

-

1

-

27 3/4

 

705

57 3/8

 

1457

-

1

-

1

-

28 1/4

 

718

58 3/8

 

1483

-

-

-

-

1

30 3/4

 

781

62 1/2

 

1588

1

-

-

-

1

 

 

 

 

 

 

 

 

 

 

 

33 3/4

 

857

67 3/4

 

1721

-

1

-

-

1

36 3/4

 

933

73

 

1854

-

-

1

-

1

 

 

 

 

 

 

 

 

 

 

 

39 3/4

 

1010

78 1/8

 

1984

-

-

-

2

-

41 1/8

 

1045

82 3/8

 

2092

1

-

-

2

-

 

 

 

 

 

 

 

 

 

 

 

45 3/4

 

1162

88 1/2

 

2248

-

-

-

1

1

 

 

 

 

 

 

 

 

 

 

 

48 1/8

 

1222

92 3/4

 

2356

1

-

-

1

1

51 3/4

 

1314

98 7/8

 

2511

-

-

-

-

2

Proper assembly of air cooled chimney parts results in an overlap of chimney joints of 1-1/4 in. (32 mm). Effective length is built into this table.

A

B

1-1/4 in. (32 mm)

OVERLAP

Figure 5.3 Chimney Offset/Return

Example: Your “A” dimension from Figure

5.3is 14 1/2 in. (368 mm). Using Table

5.2the dimension closest to, but not less than 14 1/2 in. (368 mm) is 15 3/4 in. (400 mm) using a 30° offset/return. It is then determined from the table that you would need 36 5/8 in. (930 mm) (Dimen- sion “B”) between the offset and return. The chimney components that best fit your application are two SL1112s.

18

Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07

Image 18
Contents Hot glass will cause burns Fire RiskListing Label Information/Location GrateNumber Table of Contents Listing and Code Approvals Appliance CertificationNot intended for use as a primary heat source Negative Pressure Design and Installation ConsiderationsGetting Started Asphyxiation RiskMarginal Location Typical Fireplace System Typical Fireplace SystemTools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Framing and Clearances Selecting Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceConstruct the Chase Chimney RequirementsSharp Edges Asphyxiation Risk Installation of FireplaceInstall the Outside Air Kit Risk of Smoke SpillageFt min. from top of uppermost chimney section to air inlet Place the Protective Metal Hearth Strips Secure the FireplacePosition the Fireplace Level the FireplaceChimney Assembly Height of Chimney Components Using Offsets/Returns SL1106 SL1112 SL1118 SL1136 SL1148Install the Ceiling Firestops Assemble the Chimney Sections¨E. Install the Attic Insulation Shield Away from chimney pipe may cause fireDouble-check the Chimney Assembly Secure the ChimneyComplete the Enclosure Chimney TerminationChimney Termination Requirements See Figures 6.1 Mark the Exit Point of the Roof Install the Roof FlashingInstall the Chimney Air Kit required in Canada ¨ Cut Out the Hole in the RoofInstall the Termination Cap Chase TopInstalling an ST1175 Square Termination Cap Accessories Gas Log/Lighter ProvisionsGas Code, Ansi Z223.1 Finishing Hearth Extension¨ Table Finishing Material Combustible MaterialNon-Combustible Material Mantel Glass DoorsOperating Instructions General InformationFlue Damper Outside AirClear Space Near the Fireplace FirescreenFirewood GrateWood Fuel MoistureStarting a Fire Troubleshooting Understanding Vent ProblemsSolutions Diagnostics and Problem SolvingDiagnostic Questions Can’t get a good fire going. What am I doing wrong?fireplace burns the wood too fast. What can I do? Disposal of Ashes Maintenance and Servicing the FireplaceChimney Inspection/Cleaning Firebox RefractoryClean Maintenance Task ListWhen cleaning glass door Chimney FireFireplace Dimensions Reference MaterialsFireplace Components Catalog # DescriptionChimney Components Catalog #14-1/2 15-3/4 400 mm European Copper Caps TR442 TR442 / 444 TV Minimum Base Dimensions 28 X 28 with 32 X 32 with 23 XMinimum Base Dimensions 26.5 X 28 with 34 X 34 with 20 xService Parts BAY-40Description of Part Part Number Qty.req GR3PIER-40 # Description of Part QtyThis page intentionally left blank Warranty For Heat & GLO Fireplaces Limited WarrantyDo not Discard this Manual

BAY-40 specifications

The Heat & Glo LifeStyle BAY-40 is a modern gas fireplace designed to deliver both style and functionality while enhancing the ambiance of any living space. Touted for its sleek design and advanced features, the BAY-40 serves as a centerpiece that combines warmth with contemporary aesthetics.

One of the most notable aspects of the LifeStyle BAY-40 is its impressive heat output, ensuring that rooms remain cozy even in the coldest months. With a variety of heat settings, users can easily adjust the temperature to their comfort level. This versatility makes it an ideal option for any home, whether for an expansive living area or a more compact setting.

The BAY-40 is equipped with an innovative IntelliFire technology that promotes ease of use and safety. This advanced ignition system eliminates the need for manual lighting, allowing users to start their fire at the push of a button. Additionally, the remote control feature offers convenience, enabling homeowners to control the fireplace from across the room, adding to the overall comfort factor.

Aesthetically, the LifeStyle BAY-40 is designed with a contemporary look in mind. Its large viewing area provides an unobstructed view of the flames, creating a warm and inviting atmosphere. The unique bay design not only enhances the visual appeal but also allows for a wider flame presentation, adding to the overall warmth of the room.

The fireplace also offers customizable options, such as different interior finishes and decorative media like glass or logs. These choices allow homeowners to tailor the fireplace to match their existing décor, contributing to a cohesive design throughout their home.

Moreover, the BAY-40 incorporates advanced safety features such as an automatic shut-off mechanism that activates in case of malfunction, ensuring peace of mind for users.

In summary, the Heat & Glo LifeStyle BAY-40 is more than just a fireplace; it’s a blend of innovation, design, and efficiency. Whether you are seeking to enhance your living space or provide warmth to your home, the BAY-40 stands out as an exceptional choice that balances modern technology with elegant aesthetics. Its range of features ensures both comfort and safety, making it a prime addition to any home.