Heat & Glo LifeStyle BAY-40 owner manual Table of Contents

Page 3

Table of Contents

1 Listing and Code Approvals

4

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . 4

2 Getting Started

5

A. Design and Installation Considerations . . . . . . . . . . . . 5

B. Negative Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

C. Typical Fireplace System . . . . . . . . . . . . . . . . . . . . . . . 7

D. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . 8

E. Inspect Fireplace and Components . . . . . . . . . . . . . . . 8

3 Framing and Clearances

9

A. Selecting Fireplace Location . . . . . . . . . . . . . . . . . . . . 9

B. Clearances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

C. Sidewalls/Surrounds . . . . . . . . . . . . . . . . . . . . . . . . . 11

E. Construct the Chase . . . . . . . . . . . . . . . . . . . . . . . . . 12

F. Chimney Requirements . . . . . . . . . . . . . . . . . . . . . . . 12

4 Installation of Fireplace

13

A. Install the Outside Air Kit . . . . . . . . . . . . . . . . . . . . . . 13

5 Chimney Assembly

16

A. Chimney Requirements . . . . . . . . . . . . . . . . . . . . . . . 17

B. Using Offsets/Returns . . . . . . . . . . . . . . . . . . . . . . . . 18

C. Assemble the Chimney Sections . . . . . . . . . . . . . . . . 19

D. Install the Ceiling Firestops . . . . . . . . . . . . . . . . . . . . 19

E. Install the Attic Insulation Shield . . . . . . . . . . . . . . . . 20

F. Double-check the Chimney Assembly . . . . . . . . . . . . 21

G. Secure the Chimney . . . . . . . . . . . . . . . . . . . . . . . . . 21

6 Complete the Enclosure

22

A. Chimney Termination . . . . . . . . . . . . . . . . . . . . . . . . . 22

B. Chase Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

C. Install the Termination Cap . . . . . . . . . . . . . . . . . . . . 24

7 Accessories

26

A. Gas Log/Lighter Provisions . . . . . . . . . . . . . . . . . . . . 26

8 Finishing

27

A. Hearth Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

B. Finishing Material. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

C. Mantel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

D. Sidewalls/Surrounds . . . . . . . . . . . . . . . . . . . . . . . . . 29

E. Glass Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

9 Operating Instructions

30

A. General Information . . . . . . . . . . . . . . . . . . . . . . . . . . 30

B. Outside Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

C. Clear Space Near the Fireplace. . . . . . . . . . . . . . . . . 31

D. Flue Damper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

E. Firescreen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

F. Glass Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

G. Grate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

H. Wood Fuel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

I. Starting a Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

10 Troubleshooting

34

A. Understanding Vent Problems . . . . . . . . . . . . . . . . . . 34 B. Diagnostics and Problem Solving . . . . . . . . . . . . . . . 35

11 Maintenance and Servicing the Fireplace 37

A. Disposal of Ashes . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

B. Chimney Inspection/Cleaning . . . . . . . . . . . . . . . . . . 37

C. Firebox Refractory . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

D. Maintenance Task List . . . . . . . . . . . . . . . . . . . . . . . . 38

E. Chimney Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

12 Reference Materials

39

A. Fireplace Dimensions . . . . . . . . . . . . . . . . . . . . . . . . 39

B. Fireplace Components. . . . . . . . . . . . . . . . . . . . . . . . 40

C. Chimney Components . . . . . . . . . . . . . . . . . . . . . . . . 41

D. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

E. Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

F. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Note: An arrow (¨) found in the text signifies change in content.

Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07

3

Image 3
Contents Fire Risk Hot glass will cause burnsListing Label Information/Location GrateNumber Table of Contents Listing and Code Approvals Appliance CertificationNot intended for use as a primary heat source Asphyxiation Risk Design and Installation ConsiderationsGetting Started Negative PressureMarginal Location Typical Fireplace System Typical Fireplace SystemTools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsChimney Requirements Construct the ChaseRisk of Smoke Spillage Installation of FireplaceInstall the Outside Air Kit Sharp Edges Asphyxiation RiskFt min. from top of uppermost chimney section to air inlet Level the Fireplace Secure the FireplacePosition the Fireplace Place the Protective Metal Hearth StripsChimney Assembly Height of Chimney Components SL1106 SL1112 SL1118 SL1136 SL1148 Using Offsets/ReturnsAssemble the Chimney Sections Install the Ceiling FirestopsAway from chimney pipe may cause fire ¨E. Install the Attic Insulation ShieldSecure the Chimney Double-check the Chimney AssemblyComplete the Enclosure Chimney TerminationChimney Termination Requirements See Figures 6.1 ¨ Cut Out the Hole in the Roof Install the Roof FlashingInstall the Chimney Air Kit required in Canada Mark the Exit Point of the RoofChase Top Install the Termination CapInstalling an ST1175 Square Termination Cap Accessories Gas Log/Lighter ProvisionsGas Code, Ansi Z223.1 Finishing Hearth Extension¨ Table Finishing Material Combustible MaterialNon-Combustible Material Glass Doors MantelGeneral Information Operating InstructionsFirescreen Outside AirClear Space Near the Fireplace Flue DamperMoisture GrateWood Fuel FirewoodStarting a Fire Understanding Vent Problems TroubleshootingCan’t get a good fire going. What am I doing wrong? Diagnostics and Problem SolvingDiagnostic Questions Solutionsfireplace burns the wood too fast. What can I do? Firebox Refractory Maintenance and Servicing the FireplaceChimney Inspection/Cleaning Disposal of AshesChimney Fire Maintenance Task ListWhen cleaning glass door CleanReference Materials Fireplace DimensionsCatalog # Description Fireplace ComponentsCatalog # Chimney Components14-1/2 15-3/4 400 mm European Copper Caps 20 x Minimum Base Dimensions 28 X 28 with 32 X 32 with 23 XMinimum Base Dimensions 26.5 X 28 with 34 X 34 with TR442 TR442 / 444 TVBAY-40 Service PartsGR3 Description of Part Part Number Qty.reqPIER-40 Qty # Description of PartThis page intentionally left blank Limited Warranty Warranty For Heat & GLO FireplacesDo not Discard this Manual

BAY-40 specifications

The Heat & Glo LifeStyle BAY-40 is a modern gas fireplace designed to deliver both style and functionality while enhancing the ambiance of any living space. Touted for its sleek design and advanced features, the BAY-40 serves as a centerpiece that combines warmth with contemporary aesthetics.

One of the most notable aspects of the LifeStyle BAY-40 is its impressive heat output, ensuring that rooms remain cozy even in the coldest months. With a variety of heat settings, users can easily adjust the temperature to their comfort level. This versatility makes it an ideal option for any home, whether for an expansive living area or a more compact setting.

The BAY-40 is equipped with an innovative IntelliFire technology that promotes ease of use and safety. This advanced ignition system eliminates the need for manual lighting, allowing users to start their fire at the push of a button. Additionally, the remote control feature offers convenience, enabling homeowners to control the fireplace from across the room, adding to the overall comfort factor.

Aesthetically, the LifeStyle BAY-40 is designed with a contemporary look in mind. Its large viewing area provides an unobstructed view of the flames, creating a warm and inviting atmosphere. The unique bay design not only enhances the visual appeal but also allows for a wider flame presentation, adding to the overall warmth of the room.

The fireplace also offers customizable options, such as different interior finishes and decorative media like glass or logs. These choices allow homeowners to tailor the fireplace to match their existing décor, contributing to a cohesive design throughout their home.

Moreover, the BAY-40 incorporates advanced safety features such as an automatic shut-off mechanism that activates in case of malfunction, ensuring peace of mind for users.

In summary, the Heat & Glo LifeStyle BAY-40 is more than just a fireplace; it’s a blend of innovation, design, and efficiency. Whether you are seeking to enhance your living space or provide warmth to your home, the BAY-40 stands out as an exceptional choice that balances modern technology with elegant aesthetics. Its range of features ensures both comfort and safety, making it a prime addition to any home.