Heat & Glo LifeStyle BAY-40 Assemble the Chimney Sections, Install the Ceiling Firestops

Page 19

C. Assemble the Chimney Sections

Attach either a straight chimney section or an offset to the top of the fireplace (depending on your installation require- ment). Chimney sections are locked together by pushing downward until the top section meets the stop bead on the lower section.

The inner flue is placed to the inside of the flue section below it. The outer casing is placed outside the outer casing of the chimney section below it. See Figure 5.4.

Figure 5.4 Assembling Chimney Sections

Note: Inner flue and outer liner sections cannot be disas- sembled once locked together. Plan ahead to ensure the proper installation height is achieved with the selected chimney components.

WARNING

Fire Risk

Do NOT install substitute or damaged chimney components.

MUST use chimney system described in this manual.

NO OTHER chimney components may be used.

Substitute or damaged chimney components may impair safe operation.

D. Install the Ceiling Firestops

Mark and cut an opening in the ceiling for the ceiling firestop being used. See Figure 5.5.

Frame the opening with the same size lumber used in the ceiling joists.

Install the ceiling firestop.

Note: The ceiling firestop MUST be nailed to the bottom of the ceiling joists EXCEPT when the space above is uninsulated and the attic insulation shield is not being used (see Figure 5.5). When the attic insulation shield is used the ceiling firestop may be above or below the joist of an insulated ceiling.

ROOM ABOVE (non-insulated ceiling)

B

A

Ceilng firestop from

bottom

ATTIC ABOVE (insulated ceiling)

Ceiling firestop from

When attic insulation

top

shield not used

Note: Use same dimensional lumber for framing ceiling firestop and joists.

 

A

 

 

B

Catalog #

in.

 

mm

in.

 

mm

FS538

17

 

432

17

 

432

FS540

17

 

432

26

 

660

Figure 5.5 Installing the Ceiling Firestop

Note: You must provide support for the pipe during con- struction and check to be sure inadvertent loading has not dislodged the chimney section from the fireplace or at any chimney joint.

CAUTION

Ceiling firestops must be used at ceiling/floor.

Chase construction requires ceiling firestops at each floor or every 10 ft (3.05 m) of clear space.

Use same dimensional lumber as joists.

Ceiling firestop slows spread of fire and reduces cold air infiltration.

Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 11/07

19

Image 19
Contents Fire Risk Hot glass will cause burnsGrate Listing Label Information/LocationNumber Table of Contents Appliance Certification Listing and Code ApprovalsNot intended for use as a primary heat source Asphyxiation Risk Design and Installation ConsiderationsGetting Started Negative PressureMarginal Location Typical Fireplace System Typical Fireplace SystemInspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsChimney Requirements Construct the ChaseRisk of Smoke Spillage Installation of FireplaceInstall the Outside Air Kit Sharp Edges Asphyxiation RiskFt min. from top of uppermost chimney section to air inlet Level the Fireplace Secure the FireplacePosition the Fireplace Place the Protective Metal Hearth StripsChimney Assembly Height of Chimney Components SL1106 SL1112 SL1118 SL1136 SL1148 Using Offsets/ReturnsAssemble the Chimney Sections Install the Ceiling FirestopsAway from chimney pipe may cause fire ¨E. Install the Attic Insulation ShieldSecure the Chimney Double-check the Chimney AssemblyChimney Termination Complete the EnclosureChimney Termination Requirements See Figures 6.1 ¨ Cut Out the Hole in the Roof Install the Roof FlashingInstall the Chimney Air Kit required in Canada Mark the Exit Point of the RoofChase Top Install the Termination CapInstalling an ST1175 Square Termination Cap Gas Log/Lighter Provisions AccessoriesGas Code, Ansi Z223.1 Hearth Extension Finishing¨ Table Combustible Material Finishing MaterialNon-Combustible Material Glass Doors MantelGeneral Information Operating InstructionsFirescreen Outside AirClear Space Near the Fireplace Flue DamperMoisture GrateWood Fuel FirewoodStarting a Fire Understanding Vent Problems TroubleshootingCan’t get a good fire going. What am I doing wrong? Diagnostics and Problem SolvingDiagnostic Questions Solutionsfireplace burns the wood too fast. What can I do? Firebox Refractory Maintenance and Servicing the FireplaceChimney Inspection/Cleaning Disposal of AshesChimney Fire Maintenance Task ListWhen cleaning glass door CleanReference Materials Fireplace DimensionsCatalog # Description Fireplace ComponentsCatalog # Chimney Components14-1/2 15-3/4 400 mm European Copper Caps 20 x Minimum Base Dimensions 28 X 28 with 32 X 32 with 23 XMinimum Base Dimensions 26.5 X 28 with 34 X 34 with TR442 TR442 / 444 TVBAY-40 Service PartsGR3 Description of Part Part Number Qty.reqPIER-40 Qty # Description of PartThis page intentionally left blank Limited Warranty Warranty For Heat & GLO FireplacesDo not Discard this Manual

BAY-40 specifications

The Heat & Glo LifeStyle BAY-40 is a modern gas fireplace designed to deliver both style and functionality while enhancing the ambiance of any living space. Touted for its sleek design and advanced features, the BAY-40 serves as a centerpiece that combines warmth with contemporary aesthetics.

One of the most notable aspects of the LifeStyle BAY-40 is its impressive heat output, ensuring that rooms remain cozy even in the coldest months. With a variety of heat settings, users can easily adjust the temperature to their comfort level. This versatility makes it an ideal option for any home, whether for an expansive living area or a more compact setting.

The BAY-40 is equipped with an innovative IntelliFire technology that promotes ease of use and safety. This advanced ignition system eliminates the need for manual lighting, allowing users to start their fire at the push of a button. Additionally, the remote control feature offers convenience, enabling homeowners to control the fireplace from across the room, adding to the overall comfort factor.

Aesthetically, the LifeStyle BAY-40 is designed with a contemporary look in mind. Its large viewing area provides an unobstructed view of the flames, creating a warm and inviting atmosphere. The unique bay design not only enhances the visual appeal but also allows for a wider flame presentation, adding to the overall warmth of the room.

The fireplace also offers customizable options, such as different interior finishes and decorative media like glass or logs. These choices allow homeowners to tailor the fireplace to match their existing décor, contributing to a cohesive design throughout their home.

Moreover, the BAY-40 incorporates advanced safety features such as an automatic shut-off mechanism that activates in case of malfunction, ensuring peace of mind for users.

In summary, the Heat & Glo LifeStyle BAY-40 is more than just a fireplace; it’s a blend of innovation, design, and efficiency. Whether you are seeking to enhance your living space or provide warmth to your home, the BAY-40 stands out as an exceptional choice that balances modern technology with elegant aesthetics. Its range of features ensures both comfort and safety, making it a prime addition to any home.