Step 10. Finishing

Figure 13 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 2 and 3 for other fireplace clearances.

Only non-combustible materials may be used to cover the black fireplace front.

WARNING: WHEN FINISHING THE FIREPLACE,

!NEVER OBSTRUCT OR MODIFY THE AIR IN- LET/OUTLET GRILLES IN ANY MANNER.

CEILING

12"

31”

12”

TOP FRONT EDGE

OF FIREPLACE

Figure 13.

Minimum Vertical and Maximum Horizontal Dimensions of Combustibles above Fireplace

CAUTION: IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 300° F. MINIMUM SEALANT MATE-

RIAL MUST BE USED. THESE JOINTS ARE NOT RE- QUIRED TO BE SEALED. ONLY NON-COMBUSTIBLE MATERIAL (USING 300° F. MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIRE- PLACE SURROUND. SEE THE DIAGRAM BELOW.

NON-COMBUSTIBLE ZONE

FINISH WALL MATERIAL

MATERIAL SUPPLIED WITH UNIT

MAY BE COMBUSTIBLE

 

 

- TOP AND SIDES

0”

 

2”

 

 

 

HIGH TEMPERATURE

 

 

(300F/149C. MIN.)

 

 

SEAL JOINT

 

0 ”

 

0”

Figure 14.

Sealant Material

 

Hearth Extensions

A hearth extension may be desirable for aesthetic reasons. However, ANSI or CAN/CGA testing standards do not require hearth extensions for gas fireplace appliances.

Step 11. Installing Trim, Logs, and Ember Material

Installing the Trim

Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sealed with a 300° F (149° C) minimum sealant.

WARNING: WHEN FINISHING THE FIREPLACE,

!NEVER OBSTRUCT OR MODIFY THE AIR INLET/ OUTLET GRILLES IN ANY MANNER.

Install optional marble and brass trim surround kits as desired. Marble, brass, brick, tile, or other non-combustible materials can be used to cover up the gap between the sheet rock and the fireplace.

Do not obstruct or modify the air inlet/outlet grilles. When overlapping on both sides, leave enough space so that the bottom grille can be lowered and the trim door removed.

Positioning the Logs

If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the instructions that accompany the logs. Save the log instructions with this manual.

If sooting occurs, the logs might need to be repositioned slightly to avoid excessive flame impingement.

Shutter Setting

 

NG

LP

___________________________________________

Burner

3/8”

1/2”

 

 

 

Placing the Ember Material

Ember material is shipped with this gas fireplace.

To place the ember material:

Pull the four glass latches off of the tabs on the glass frame. Remove glass door from the unit (see Figure 15).

Embers CANNOT be placed directly over ports. Care should be taken not to cover the lighting trail of ports (from back to front).

When placing Glowing embers onto the burner care should be taken so that the ports are not covered. Place the embers along side the port trail, but not on or in between the ports. Failure to follow this procedure will likely cause lighting and sooting problems.

Save the remaining ember materials for use during fire- place servicing. The bag of embers provided is sufficient for 3 to 5 applications.

Replace the glass door and a front trim door on the unit.

Pull out and latch the glass clips onto the tabs on the glass frame.

18

Image 18
Contents Installers Guide What to do if you smell gasSafety and Warning Information Table of Contents Service Parts Log Set AssemblyCommon Parts / Piéces Communes Standing Pilot Ignition Valve Assembly Intermittent Pilot Ignition Valve Assembly 8000TVD-IPI1Approvals Codes Installation CodesHigh Altitude Installations Appliance CertificationIntroducing the Heat-N-Glo Gas Fireplaces Pre-install Preparation2Getting Started Unit with damaged, incomplete, or substitute partsDiagram of 8000TVD 3Installing the Fireplace Locating the FireplaceFraming the Fireplace Installing Optional Outside Make-up Air Negative Pressure Make-up AirAir Damper Rise to RUN Ratio = Installing the Vent System Vent System ApprovalsSystem Components Maximum NO. Of Elbows 2 90o or 4 45oGas Control Systems Vice Must be Wired to the Fireplace Junction BOXPositioning, Leveling, and Securing the Fireplace Roof PitchPressure Natural Gas Propane Gas Supply LineGas Pressure Requirements Standing PilotWall Switch Wiring the FireplaceFor Standing Pilot Ignition Wiring Appliance Requirements Optional AccessoriesFor Intermittent Pilot Ignition IPI Wiring Volt Transformer Operation using Battery PowerInstalling Trim, Logs, and Ember Material FinishingBefore Lighting the Fireplace After the InstallationDouble-check for faulty components Lighting the FireplaceFireplace Maintenance Maintaining and Servicing Your FireplaceImportant Turn OFF the GAS Before Servicing Your Fireplace