Heat & Glo LifeStyle AT-GRAND-D manual Installing the Insert, Step Installing the Vent System

Page 12

3

Installing the Insert

Installation

 

Step 1

Installing the Vent System

Vent System Installation Precautions

Before starting installation of vent kits, the installer should read these instructions and the Vent Kit Instructions to ensure that a proper vent installation is completed. Consult your local Building Codes before beginning the Installation.

!WARNING: THIS GAS INSERT AND VENT ASSEMBLY MUST BE VENTED DIRECTLY TO

THE OUTSIDE AND MUST NEVER BEATTACHED TO A CHIMNEY SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. EACH GAS APPLIANCE MUST USE A SEPARATE VENT SYSTEM. COMMON VENT SYSTEMS ARE PROHIBITED.

Vent System Approvals

Table 1 and Figure 3 through 5 shows the vent termination caps and systems approved for the use with these models. Approved vent system terminations are labeled for identification. 3-inch diameter listed flexible aluminum or stainless steel gas vent is used for both the incoming combustion air and exhaust vent pipes. NO OTHER VENTING SYSTEMS OR COMPONENTS MAY BE USED. Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this manual.

Horizontal Venting

The vent system on this model CANNOT be terminated horizontally.

Vertical Venting

The vent pipes MUST be connected to the proper collars on the unit AND the exhaust vent pipe MUST be connected to the termination cap or the unit will not operate. The combustion air vent pipe CAN be connected to the termination cap or it can terminate inside the chimney. The bottom opening of the chimney must be sealed around the vent pipes if the combustion air vent is NOT connected to the termination cap. See Figures 3, 4 and 5.

NOTE: The minimum vertical rise (exhaust vent) is 14 feet and the maximum vertical rise is 50 feet. These dimensions are measured from the starting collars of the unit to the end of the last section of vent pipe. See dimension V in Figure 3.

Étape 1

Installation du système de ventilation

Précautions à respecter pour l’installation du système de ventilation

Avant de commencer la pose des kits de ventilation, lire les instructions suivantes et les instructions des kits pour as- surer une installation correcte. Consulter les codes de con- struction locaux avant de commencer l’installation.

!AVERTISSEMENT: CET APPAREIL DE CHAUFFAGE AU GAZ ET SON SYSTÈME DE

VENTILATION DOIVENT COMMUNIQUER DIRECTEMENT AVEC L’AIR EXTÉRIEUR ET NE DOIVENT JAMAIS ÊTRE RACCORDÉS À UNE CHEMINÉE DESSERVANT UN APPAREIL SÉPARÉ BRÛLANT DES COMBUSTIBLES SOLIDES. CHAQUE APPAREILAU GAZ DOIT DISPOSER D’UN SYSTÈME DE VENTILATION SÉPARÉ. LES SYSTÈMES DE VENTILATION COMMUNS À PLUSIEURS APPAREILS SONT INTERDITS.

Homologations du système de ventilation

Le tableau 1 et les figures 3 à 5 montrent les systèmes de ventilation et mitres approuvés pour le modèle présenté dans ce guide. Les autocollants apposés sur les mitres signalent l’homologation. Un système de ventilation flexible homologué de 7,62 cm (3 in.) de diamètre en aluminium ou acier inoxydable sert à la fois pour les conduits d’entrée de l’air de combustion et les conduits de refoulement des gaz d’échappement. N’UTILISER AUCUN AUTRE SYSTÈME OU ÉLÉMENTS DE SYSTÈME. Des notices de montage détaillées accompagnent chaque kit de mitre et doivent être utilisées en conjonction avec ce guide.

Ventilation Horizontale

Le système de ventilation de ce modèle NE PEUT PAS se terminer par une section horizontale.

Ventilation Verticale

Les conduits de ventilation DOIVENT être raccordés aux colliers appropriés de l’appareil de chauffage ET la tuyauterie des gaz d’échappement DOIT être raccordée à la mitre, sinon l’appareil ne peut pas fonctionner. Le conduit d’air de combustion PEUT être raccordé à la mitre ou aboutir à l’intérieur de la cheminée. Cependant, l’ouverture inférieure de la cheminée doit être scellée autour des tuyaux de ventilation si le conduit d’air de combustion N’est PAS raccordé à la mitre. Voir les figures 3, 4 et 5.

REMARQUE: La hauteur verticale minimum (conduit d’échappement) est de 4,2 m (14 ft) et la hauteur verticale maximum est de 15 m (50 ft). Mesurer ces dimensions à partir des colliers de départ de l’appareil de chauffage jusqu’au bout de la dernière section de conduits de ventilation. Voir la dimension V (hauteur verticale) à la figure 3.

12

Image 12
Contents Guide d’installation Safety and Warning Information Page Table of Contents Service Parts Log Set AssemblyAccessories / Accessoires 1Approvals and Codes Approval Listing and CodesHomologations et codes Approvals and Codes Homologations et codes suite Pre-installation Preparation Avant l’installation ANY Such Action MAY Possibly Cause a Fire HAZARD CES Situations Peuvent Créer DES RisquesGetting Started Mise en marche suite Diagram of the AT-GRAND-D Installing the Insert Step Installing the Vent SystemÉtape Installation du système de ventilation Connecting the Vent Pipe Vent System ApprovalsRaccordement du conduit de ventilation HomologationsMinimum Height from Roof to Lowest Discharge Opening Installing the Insert Installing the Insert Installation suite DE Commande SUR 110-120 VCA Standing Pilot Ignition SystemAllumage par veilleuse Gas Controls SystemsStep Gas Supply Line Étape 4 Raccordement au gazApproved and/or licensed as required by the locality Fuites DE GAZ Avec UNE Flamme NUEStep Gas Pressure Requirements Étape Spécifications relatives La pression du gazPressure Natural Gas Propane Pression Gaz naturel PropaneAdvertissement NE PAS Raccorder LA GAS Control Valve orTout Fonctionne Normalement Step Installing Logs and Ember Material Étape Pose des bûches et des braisesGlass Assembly Porte en verre Placement Pose des braises Ember MaterialLift the top trim door up Déposer la porteChauffage Avant D’INSTALLER L’ENCADREMENT Avertissement Lors DE LA Finition DERemarque Déposer L’ENCADREMENT Frontal DE LA Porte ET LA Porte EN Verre DE L’APPAREIL DEMARCHE/ARRÊT After the Installation Après l’installationStep Before Lighting the Appliance Step Lighting the ApplianceRemplacement des braises usagées Maintaining 4Servicing Your Appliance Entretien et révisionReplacing old ember material Checking Flame Patterns, Flame HeightCleaning Glass Door Attempt to clean the doorWhen it is hot and do not use Abrasive cleaners

AT-GRAND-D specifications

The Heat & Glo LifeStyle AT-GRAND-D is an impressive gas fireplace that combines advanced technology with contemporary design. This innovative product caters to homeowners seeking both aesthetic appeal and functional warmth, making it suitable for a variety of living spaces.

One of the standout features of the AT-GRAND-D is its expansive viewing area, providing an unobstructed view of the flames. The large glass front enhances the ambiance of any room while maximizing the visual impact of the fire. The fireplace is designed to fit seamlessly into modern and traditional decor, thanks to its diverse finishing options and customizable installation features.

The AT-GRAND-D incorporates advanced technology to enhance efficiency and comfort. One notable technology is the IntelliFireā„¢ ignition system, which offers reliable and easy start-ups. This system ensures that the fireplace ignites quickly at the push of a button, eliminating the hassle of manual lighting. Additionally, it features an optional remote control that allows users to adjust the flame height and heat output, providing the ultimate convenience.

Safety is also a priority in the design of the AT-GRAND-D. It includes a safety screen that prevents accidental contact with the glass, ensuring peace of mind for families with children and pets. The unit is equipped with a temperature sensor, allowing it to automatically adjust the flame to maintain a comfortable environment and prevent overheating.

Another key characteristic of the Heat & Glo LifeStyle AT-GRAND-D is its impressive heat output. With a powerful BTU range, it is capable of effectively heating large areas, making it an excellent heating solution for open-concept living spaces or cozy nooks. Additionally, the fireplace is designed for energy efficiency, providing warmth while minimizing energy consumption.

The AT-GRAND-D offers customizable installation options, including the ability to use it as a built-in unit or as a standalone model with a sleek surround. This adaptability allows homeowners to create a unique focal point in their home that suits their specific needs and style preferences.

In summary, the Heat & Glo LifeStyle AT-GRAND-D gas fireplace is a top-tier option for those looking to enhance their living space with warmth and elegance. Its combination of cutting-edge technology, safety features, and stylish design makes it an excellent choice for any modern home.