Heat & Glo LifeStyle AT-GRAND-D Connecting the Vent Pipe, Vent System Approvals, Homologations

Page 13

Installing the Insert (continued)

Installation (suite)

A vertical vent termination system installed on this model will include one (1) length of 3-inch flexible vent pipe for the combustion air, one (1) pipe-to-cap adaptor, and one (1) SLK- 991DA or SLK-980D vertical termination cap.

NOTE: The damper of the masonry chimney may need to be removed to allow installation of the flexible-vent pipe.

This fireplace has been altered to accommodate an insert and should be inspected by a qualified person prior to re-use as a conventional fireplace.

NOTE: The above label, located in the instruction package, must be affixed to the existing fireplace prior to installation of Model AT-GRAND-D.

For zero clearance, factory built woodburning fireplaces, the use of kit LINK-ZC-ADP, in place of the standard square flashing, will allow you to mount the adaptor and cap on metal pipe. Additionally, the use of kit FLASH-DAMP will seal off the damper opening when terminating the inlet air vent pipe just above the damper. These two kits are recommended for zero clearance, factory built woodburning fireplaces.

Connecting the Vent Pipe

Install the 3-inch flexible vent pipes down through the chimney. Attach and secure the bottom ends of the flex pipes to the starting collars on the unit with 3 sheetmetal screws on each collar. Slide the gas insert into place, and position any excess flex vent pipe back up into the chimney.

Attach the pipe-to-cap adaptor to the termination cap and the top of the flexible vent pipe and set the cap in place at the top of the chimney. See Figures 3, 4 & 5.

CAUTION: TO AVOID DOWNDRAFTS AND/OR COLD AIR PROBLEMS, IT IS RECOMMENDED TO SEAL OFF THE AREA BETWEEN THE TERMINATION CAPAND THE TOP OF THE SOLID-FUEL CHIMNEY OPENING INTO WHICH THE VENT CAP HAS BEEN INSTALLED.

When using the LINK-DV4-30 vent system, it is required to seal around the flexible vent pipes in the damper area. See Figure 3. Use fiberglass insulation or other suitable non- combustible material.

VENT SYSTEM APPROVALS

AT-GRAND-D LINK-DV30

LINK-DV4-30

TABLE 1

Un système de ventilation verticale installé sur ce modèle doit inclure une (1) longueur de conduit de ventilation flexible d’un diamètre de 7,62 cm (3 in.) pour l’air de combustion, un (1) raccord du conduit à la mitre et une (1) mitre pour conduit vertical SLK-991DA ou SLK-980D.

REMARQUE: Il peut s’avérer nécessaire de déposer le registre d’une cheminée en briques avant d’installer le conduit de ventilation flexible.

Lorsqu’une cheminée a été modifiée pour accepter un appareil de chauffage au gaz, elle doit être inspectée par un technicien qualifié avant d’être reconvertie en cheminée conventionnelle.

REMARQUE: L’étiquette ci-dessus, comprise dans le paquet d’instructions, doit être apposée sur la cheminée existante avant l’installation du modèle AT-GRAND-D.

Dans le cas des cheminées de feux de bois fabriquées en usine et sans espace d’isolation, utiliser le kit LINK-ZC-ADP

àla place du carré de solin ordinaire pour monter le raccord et la mitre sur le tuyau métallique. Le kit FLASH-DAMP permet de sceller l’ouverture du registre lorsque le conduit d’admission d’air se termine juste au-dessus du registre. Ces deux kits sont recommandés pour les cheminées de feux de bois fabriquées en usine et sans espace d’isolation.

Raccordement du conduit de ventilation

Installer les conduits de ventilation flexibles de 7,62 cm (3 in.) de diamètre dans la cheminée. Attacher et fixer les extrémités des conduits flexibles aux colliers de départ de l’appareil avec 3 vis à tôle sur chaque collier. Glisser l’appareil de chauffage en place et introduire le conduit flexible qui dépasse à l’intérieur de la cheminée.

Attacher le raccord prévu à cet effet entre la mitre et le haut du conduit flexible et poser la mitre au sommet. Voir les figures 3, 4 et 5.

ATTENTION: POUR ÉVITER LES TIRAGES INSUFFISANTS OU LES APPELS D’AIR FROID, IL EST RECOMMANDÉ DE SCELLER COMPLÈTEMENT L’ESPACE ENTRE LA MITRE ET L’OUVERTURE SUPÉRIEURE DE LA CHEMINÉE DE COMBUSTIBLES SOLIDES DANS LAQUELLE LA MITRE EST INSTALLÉE.

Lorsque le système de ventilation LINK-DV4-30 est utilisé, il est obligatoire de sceller l’espace entre les conduits de ventilation flexibles et l’ouverture du registre (voir la figure 3). Utiliser de la laine de verre ou un autre matériau non- combustible approprié.

HOMOLOGATIONS

AT-GRAND-D LINK-DV30

LINK-DV4-30

TABLEAU 1

13

Image 13
Contents Guide d’installation Safety and Warning Information Page Table of Contents Log Set Assembly Service PartsAccessories / Accessoires Approval Listing and Codes 1Approvals and CodesHomologations et codes Approvals and Codes Homologations et codes suite ANY Such Action MAY Possibly Cause a Fire HAZ Pre-installation Preparation Avant l’installationARD CES Situations Peuvent Créer DES RisquesGetting Started Mise en marche suite Diagram of the AT-GRAND-D Step Installing the Vent System Installing the InsertÉtape Installation du système de ventilation Vent System Approvals Connecting the Vent PipeRaccordement du conduit de ventilation HomologationsMinimum Height from Roof to Lowest Discharge Opening Installing the Insert Installing the Insert Installation suite Standing Pilot Ignition System DE Commande SUR 110-120 VCAAllumage par veilleuse Gas Controls SystemsÉtape 4 Raccordement au gaz Step Gas Supply LineApproved and/or licensed as required by the locality Fuites DE GAZ Avec UNE Flamme NUEÉtape Spécifications relatives La pression du gaz Step Gas Pressure RequirementsPressure Natural Gas Propane Pression Gaz naturel PropaneGAS Control Valve or Advertissement NE PAS Raccorder LATout Fonctionne Normalement Étape Pose des bûches et des braises Step Installing Logs and Ember MaterialPlacement Pose des braises Ember Material Glass Assembly Porte en verreLift the top trim door up Déposer la porteAvertissement Lors DE LA Finition DE Chauffage Avant D’INSTALLER L’ENCADREMENTRemarque Déposer L’ENCADREMENT Frontal DE LA Porte ET LA Porte EN Verre DE L’APPAREIL DEMARCHE/ARRÊT Après l’installation After the InstallationStep Before Lighting the Appliance Step Lighting the ApplianceMaintaining 4Servicing Your Appliance Entretien et révision Remplacement des braises usagéesReplacing old ember material Checking Flame Patterns, Flame HeightAttempt to clean the door Cleaning Glass DoorWhen it is hot and do not use Abrasive cleaners

AT-GRAND-D specifications

The Heat & Glo LifeStyle AT-GRAND-D is an impressive gas fireplace that combines advanced technology with contemporary design. This innovative product caters to homeowners seeking both aesthetic appeal and functional warmth, making it suitable for a variety of living spaces.

One of the standout features of the AT-GRAND-D is its expansive viewing area, providing an unobstructed view of the flames. The large glass front enhances the ambiance of any room while maximizing the visual impact of the fire. The fireplace is designed to fit seamlessly into modern and traditional decor, thanks to its diverse finishing options and customizable installation features.

The AT-GRAND-D incorporates advanced technology to enhance efficiency and comfort. One notable technology is the IntelliFireā„¢ ignition system, which offers reliable and easy start-ups. This system ensures that the fireplace ignites quickly at the push of a button, eliminating the hassle of manual lighting. Additionally, it features an optional remote control that allows users to adjust the flame height and heat output, providing the ultimate convenience.

Safety is also a priority in the design of the AT-GRAND-D. It includes a safety screen that prevents accidental contact with the glass, ensuring peace of mind for families with children and pets. The unit is equipped with a temperature sensor, allowing it to automatically adjust the flame to maintain a comfortable environment and prevent overheating.

Another key characteristic of the Heat & Glo LifeStyle AT-GRAND-D is its impressive heat output. With a powerful BTU range, it is capable of effectively heating large areas, making it an excellent heating solution for open-concept living spaces or cozy nooks. Additionally, the fireplace is designed for energy efficiency, providing warmth while minimizing energy consumption.

The AT-GRAND-D offers customizable installation options, including the ability to use it as a built-in unit or as a standalone model with a sleek surround. This adaptability allows homeowners to create a unique focal point in their home that suits their specific needs and style preferences.

In summary, the Heat & Glo LifeStyle AT-GRAND-D gas fireplace is a top-tier option for those looking to enhance their living space with warmth and elegance. Its combination of cutting-edge technology, safety features, and stylish design makes it an excellent choice for any modern home.