A. Chimney Requirements
Measure vertical distances from the base of the fireplace as shown in Figure 8.2.
• | Minimum overall straight height | 16.5 ft | (5.03 m) |
• | Minimum height with offset/return | 16.5 ft | (5.03 m) |
• Maximum height | 90 ft | (27.43 m) | |
• Maximum chimney length between an offset | 20 ft | (6.1 m) | |
| and return |
|
|
• Maximum distance between chimney | 35 ft | (10.67 m) | |
| stabilizers |
|
|
• | Double offset/return minimum height | 20 ft | (6.1 m) |
• Maximum unsupported chimney length | 6 ft | (1.83 m) | |
| between the offset and return |
|
|
• Maximum unsupported chimney height above | 35 ft | (10.67 m) | |
| the fireplace |
|
|
• Maximum unsupported chimney above roof | 6 ft | (1.83 m) |
WARNING! Risk of Fire! You must maintain 2 in. (51
mm)air space clearance to insulation and other combus- tible materials around the chimney system. Failure to do so may cause overheating and fire.
Table 8.1
Determine the chimney components needed to complete your particular installation:
•Measure the total vertical height of the fireplace installation from the base of the fireplace assembly to the approximate location of the bottom of the termination cap.
•Subtract the effective height of the fireplace assembly (see Figure 8.2) from the total vertical height to determine the overall height of the chimney installation.
•Create a schematic for your application similar to Figure 8.2 showing components required (referring to Table 8.1). Figure 8.1 identifies those components and where used.
•Install a ceiling firestop whenever the chimney penetrates a floor/ceiling.
NOTICE: A maximum of two pairs of offsets and returns may be used.
CAUTION! Risk of Fire and/or Asphyxiation! DO NOT connect this fireplace to a chimney flue servicing another appliance. DO NOT connect to any air distribu- tion duct or system. These actions could cause over- heating/fire in the chimney flue, or release of exhaust fumes into the living areas.
HEIGHT OF CHIMNEY COMPONENTS | in. | mm | |
Chimney Stabilizer |
|
| |
| SL3 | 121 | |
|
|
|
|
Ceiling Firestops |
|
| |
| FS338 | 0 | 0 |
| FS339 | 0 | 0 |
|
|
|
|
| FS340 | 0 | 0 |
Offsets/Returns |
|
| |
| SL315 | 340 | |
| SL330 | 394 | |
Roof Flashing |
|
| |
| RF370 | 0 | 0 |
| RF371 | 0 | 0 |
|
|
|
|
Chimney Sections* |
|
| |
| SL306 | 121 | |
| SL312 | 273 | |
|
|
|
|
| SL318 | 425 | |
| SL324 | 578 | |
| SL336 | 883 | |
|
|
|
|
| SL348 | 1187 | |
* Dimensions reflect effective height. |
|
|
20 ft (6.10 m) max. pipe between an offset & return
Ceiling firestop
(1048 mm)
Effective
Height
6 ft (1.83 m) max. unsupported chimney above roof
35 ft (10.7 m) max. straight unsupported chimney height
16.5ft (5.03 m) min. height/single
90 ft (27.4 m) max. height
Figure 8.2 Chimney Requirements