•TS345/TS345P Square Termination Cap
•European Copper Series Termination Cap
Cap top comes assembled in place.
Termination Cap
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Chimney
Pipe
Place waterproof sealer under each flange of the termina- tion cap and on top of each screw to help prevent leaks.
3 in. (76 mm)
Maximum
top of chase to top of
chimney section
Chase
Cap Top
(Be sure holes in cap top and
cap base are aligned.)
Cap Base
brass screw (8)
(9 for the
bolt (8)*
Termination cap pipe and chimney section must overlap
Figure 9.7 Installing a TS345/TS345P Square Termination Cap
•TCT375 Terra Cotta Cap
bracket (8)* screw (8)*
chase top
(metal or masonry)
nut (8)* washer (8)*
2 in. (51 mm) typical collar height
Place waterproof sealer under each flange of the termina- tion cap and on top of each screw to help prevent leaks.
SL pipe
(368 mm)
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Termination Cap
The last section of pipe must stop between 2 in. (51 mm) above top of chase and 7 in. (178 mm) below top of chase
2 in. (51 mm)
7 in. (178 mm)
Chase
Chimney
Pipe
Figure 9.9 Installing an Adapter for European Copper Cap Se- ries
Termination cap pipe and chimney section must overlap
Figure 9.8 Installing a TCT375 Terra Cotta Cap
34 | Heat & Glo • |