5 Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

V1

First section (closest to appliance) of vertical length

 

 

V2

Second section of vertical length

 

 

H1

First section (closest to appliance) of horizontal length

 

 

H2

Second section of horizontal length

 

 

Vertical

-8 in.1/2

8-1/2 in.

WARNING

Horizontal

Fire Hazard.

 

Explosion Risk.

Figure 5.1

Asphyxiation Risk.

 

Do NOT connect this gas appliance to a chimney

C. Measuring Standards

flue serving a separate solid-fuel or gas burning

appliance.

Vertical and horizontal measurements listed in the vent

• Vent this appliance directly outside.

diagrams were made using the following standards.

• Use separate vent system for this appliance.

1. Pipe measurements are shown using the effective length

May impair safe operation of this appliance or

of pipe (see Figure 5.2).

other appliances connected to the flue.

 

2. Measurements are made from the appliance outer wrap,

B. Use of Elbows

not from the standoffs.

3. Horizontal terminations are measured to the outside

 

CAUTION

mounting surface (flange of termination cap) (see

Figure 4.1).

ALL vent configuration specifications MUST be followed.

4. Vertical terminations are measured to bottom of termi-

nation cap.

• This product is tested and listed to these specifications.

5. Horizontal pipe installed level with no rise.

• Appliance performance will suffer if specifications are not

followed.

 

Diagonal runs have both vertical and horizontal vent as-

 

 

 

 

 

Pipe

Effective Length

 

 

 

 

 

Inches

Millimeters

 

 

 

 

 

 

pects when calculating the effects. Use the rise for the

 

 

 

 

 

DVP4

4

102

vertical aspect and the run for the horizontal aspect (see

 

 

 

 

 

DVP6

6

152

Figure 5.1).

 

 

 

 

Effective

DVP12

12

305

Two 45º elbows may be used in place of one 90º elbow. On

 

 

 

 

Height/Length

DVP24

24

610

 

 

 

 

 

 

 

 

 

 

DVP36

36

914

45º runs, one foot of diagonal is equal to 8.5 inches hori-

 

 

 

 

 

 

 

 

 

 

DVP48

48

1219

zontal run and 8.5 inches vertical run. A length of straight

 

 

 

 

 

 

 

 

 

 

DVP6A

3 to 6 76 to 152

pipe is allowed between two 45º elbows (see Figure 5.1).

 

 

 

 

 

 

 

 

 

 

DVP12A

3 to 12

76 to 305

 

 

 

 

 

 

 

 

 

 

 

 

DVP12MI

3 to 12

76 to 305

 

 

 

 

 

 

DVP24MI

3 to 24

76 to 610

 

 

Figure 5.2 DVP Pipe Effective Length

 

 

Heat & Glo • Crescent II

2083-902

Rev. N

7/09

 

 

13

Image 13
Contents Hot glass will cause burns What to do if you smell gasHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededInspect Firebox Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseClearances to mantels or other combustibles above appliance Mantel ProjectionsVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Vent Table Key Vent Information and DiagramsMeasuring Standards Use of ElbowsTop Vent Horizontal Termination One Elbow Vent DiagramsTwo Elbows Minimum MaximumV1 Min H1 Max V2 Min H2 Max Top Vent Horizontal Termination Three ElbowsH1 Maximum V1 + V2 Minimum Restrictor PlatePipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Securing and Leveling the Appliance Appliance PreparationAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Roof Pitch Min. Ft Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Connecting to the Appliance Recommendation for WireOptional Remote Control Requirements Electrical InformationHeat & Glo Crescent II 2083-902 Rev. N Intermittent Installing Flame Control Solenoid Natural Gas Only Junction Box InstallationFacing Requirements FinishingOutside Fit Surround For Outside Fit SurroundsInside Fit Surround Inside Facing DimensionsClean the Appliance Appliance SetupAccessories Remove Shipping MaterialsPositioning the Logs Log Set Assembly LOGS-CrescentSRV2083-185Final placement appearance Removing Glass Assembly Glass AssemblyReplacing Glass Assembly Replacing Light BulbBefore Lighting Appliance Operating InstructionsOn position. The ON/OFF switch may Turn off all electric power to the applianceLighting Appliance IPI Ignition Final inspection byInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramLocation Inches Millimeter DVP vent components Heat & Glo Crescent II Rev. N Vent Components DiagramsHeat Shield Horizontal Termination Cap Wall Shield FirestopHorizontal Termination Cap Kit DRC-RADIUS DVP-HRC, DVP-HRC-SS Service Parts Log Set AssemblyPart number list on following Beginning Manufacturing Date AprilStocked Service Parts ListAt Depot Limited Lifetime Warranty Limited Lifetime Warranty Contact Information

CRESCENT II specifications

The Heat & Glo LifeStyle CRESCENT II is a remarkable gas fireplace that seamlessly combines elegance and functionality, making it an ideal choice for modern homes. Designed to offer both comfort and aesthetic appeal, this fireplace brings warmth and sophistication to any living space.

One of the main features of the CRESCENT II is its sleek, contemporary design. The fireplace boasts a unique crescent-shaped front that provides an expansive view of the flames, allowing for a captivating visual experience. Its clean lines and minimalistic aesthetic make it a striking centerpiece for both traditional and modern interiors.

Equipped with advanced Intellifire technology, the CRESCENT II ensures a hassle-free experience. This innovative system offers a reliable ignition process, allowing users to start their fireplace with the push of a button. The random flame pattern, an essential characteristic of this model, provides a natural and dynamic fire experience that enhances the ambiance of any room.

The Heat & Glo LifeStyle CRESCENT II also prioritizes efficiency. It features a powerful heating capacity and a balanced flue system that allows for versatile installation options. This makes it suitable for various home layouts while ensuring that heat distribution is optimized. Users can enjoy the cozy warmth of their fireplace without compromising on efficiency or air quality.

With customizable options, homeowners can tailor the firebox to their preferences. Options include different media choices, such as glass, stones, or logs, allowing for personalization that matches individual styles. The CRESCENT II also offers several finish options, from classic to modern, ensuring that it complements the unique décor of every home.

In addition to its aesthetic appeal, the CRESCENT II emphasizes safety and convenience. The fireplace includes features like a safety shut-off system and a tempered glass front, protecting both the occupants and the living environment. The easy-to-use remote control allows users to adjust the flame and heat settings conveniently from any location in the room.

Overall, the Heat & Glo LifeStyle CRESCENT II stands out as a sophisticated and efficient gas fireplace option, offering homeowners the perfect combination of style, technology, and safety. With its thoughtful features and customizable design, it creates an inviting atmosphere that enhances the beauty and comfort of any indoor space.