8 Installing Vent Pipe

A. Assembly of Vent Sections

WARNING

Do not mix pipe, fittings or joining methods from different manufacturers.

WARNING

Fire Risk

Exhaust Fumes Risk

Impaired Performance of Appliance

Overlap pipe slip sections at least 1-1/2 inches.

Use pilot holes for screws.

Screws must not exceed one inch long.

Pipe may separate if not properly joined.

Attaching Vent to the Firebox Assembly

To attach the first pipe section to the collars, slide the male end of the inner vent of the pipe section over the inner collar on the firebox assembly. At the same time, slide the outer flue over the outer collar on the appliance. Push the pipe section into the appliance collar until all the lances (see Figure 8.1) have snapped in place. Tug slightly on the sec- tion to confirm it has completely locked into place.

Assembling Pipe Sections

Insert the inner flue of section A into the flared inner flue of section B.

Start the outer flue of section A over the outer flue of section B (see Figure 8.2). Note: The end of the pipe sections with the lances/tabs on it will face towards the appliance.

Once both inner and outer flues are started, press section A onto section B firmly until all lances have snapped into place. Check to make sure they have snapped together (see Figure 8.3) and the seams are not aligned (see Fig- ure 8.4). Tug slightly on section A to confirm it has com- pletely locked into place. It is acceptable to use screws no longer than 1 inch to hold outer pipe sections together. If predrilling holes, do NOT penetrate inner pipe.

For 90° and 45° elbows that are changing the vent direction from horizontal to vertical, one screw minimum should be put in the outer flue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1 inch. If predrilling screw holes, do NOT penetrate inner pipe.

Figure 8.1 Lances

A

B

Figure 8.2

Figure 8.3

Note: Make sure that the seams are not aligned to prevent unintentional disconnection.

CORRECT

Figure 8.4 Seams

INCORRECT

20

Heat & Glo • Crescent II • 2083-902 Rev. N • 7/09

Image 20
Contents What to do if you smell gas Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsDesign and Installation Considerations Getting StartedInspect Appliance and Components Tools and Supplies NeededInspect Firebox Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Clearances to mantels or other combustibles above applianceSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Vent Information and Diagrams Vent Table KeyMeasuring Standards Use of ElbowsVent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 Min H1 Max V2 Min H2 MaxRestrictor Plate H1 Maximum V1 + V2 MinimumVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Appliance Preparation Securing and Leveling the ApplianceInstalling Vent Pipe Assembly of Vent SectionsAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Installing Roof Flashing and Vertical Termination Cap Roof Pitch Min. FtAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceOptional Remote Control Requirements Electrical InformationHeat & Glo Crescent II 2083-902 Rev. N Intermittent Junction Box Installation Installing Flame Control Solenoid Natural Gas OnlyFinishing Facing RequirementsOutside Fit Surround For Outside Fit SurroundsInside Facing Dimensions Inside Fit SurroundAppliance Setup Clean the ApplianceAccessories Remove Shipping MaterialsLog Set Assembly LOGS-Crescent Positioning the LogsSRV2083-185Final placement appearance Glass Assembly Removing Glass AssemblyReplacing Glass Assembly Replacing Light BulbOperating Instructions Before Lighting ApplianceTurn off all electric power to the appliance On position. The ON/OFF switch mayLighting Appliance IPI Ignition Final inspection byAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsLocation Inches Millimeter Appliance Dimension DiagramReference Materials Vent Components Diagrams DVP vent components Heat & Glo Crescent II Rev. NHorizontal Termination Cap Kit Horizontal Termination Cap Wall Shield FirestopHeat Shield DRC-RADIUS DVP-HRC, DVP-HRC-SS Log Set Assembly Service PartsPart number list on following Beginning Manufacturing Date AprilAt Depot Service Parts ListStocked Limited Lifetime Warranty Limited Lifetime Warranty Contact Information

CRESCENT II specifications

The Heat & Glo LifeStyle CRESCENT II is a remarkable gas fireplace that seamlessly combines elegance and functionality, making it an ideal choice for modern homes. Designed to offer both comfort and aesthetic appeal, this fireplace brings warmth and sophistication to any living space.

One of the main features of the CRESCENT II is its sleek, contemporary design. The fireplace boasts a unique crescent-shaped front that provides an expansive view of the flames, allowing for a captivating visual experience. Its clean lines and minimalistic aesthetic make it a striking centerpiece for both traditional and modern interiors.

Equipped with advanced Intellifire technology, the CRESCENT II ensures a hassle-free experience. This innovative system offers a reliable ignition process, allowing users to start their fireplace with the push of a button. The random flame pattern, an essential characteristic of this model, provides a natural and dynamic fire experience that enhances the ambiance of any room.

The Heat & Glo LifeStyle CRESCENT II also prioritizes efficiency. It features a powerful heating capacity and a balanced flue system that allows for versatile installation options. This makes it suitable for various home layouts while ensuring that heat distribution is optimized. Users can enjoy the cozy warmth of their fireplace without compromising on efficiency or air quality.

With customizable options, homeowners can tailor the firebox to their preferences. Options include different media choices, such as glass, stones, or logs, allowing for personalization that matches individual styles. The CRESCENT II also offers several finish options, from classic to modern, ensuring that it complements the unique décor of every home.

In addition to its aesthetic appeal, the CRESCENT II emphasizes safety and convenience. The fireplace includes features like a safety shut-off system and a tempered glass front, protecting both the occupants and the living environment. The easy-to-use remote control allows users to adjust the flame and heat settings conveniently from any location in the room.

Overall, the Heat & Glo LifeStyle CRESCENT II stands out as a sophisticated and efficient gas fireplace option, offering homeowners the perfect combination of style, technology, and safety. With its thoughtful features and customizable design, it creates an inviting atmosphere that enhances the beauty and comfort of any indoor space.