C. Vertical Penetration Framing

WARNING

Fire Hazard

Keep loose materials or blown insulation from touching the vent pipe.

National building codes recommend using attic shield to keep loose materials/ blown insulation from contacting vent.

Hearth & Home Technologies requires the use of an attic shield.

Installing the Ceiling Firestop

Frame an opening 10 inches by 10 inches whenever the vent system penetrates a ceiling/floor (see Figure 6.3).

Frame the area with the same sized lumber as used in ceiling/floor joist.

When installing a top vent vertical termination appliance the hole should be directly above the appliance, unless the flue is offset.

Do not pack insulation around the vent. Insulation must be kept away from the pipe.

Installing Attic Shield

Note: An additional ceiling firestop is not required if attic shield is used.

Frame opening for attic shield.

Attic shield may be installed above or below ceiling (see Figure 6.4).

Secure with three fasteners on each side.

Fold tabs at top of attic shield in toward vent pipe. Tabs must keep vent pipe centered within shield.

Field construct additional shield height if insulation is deeper than height of attic shield.

ATTIC ABOVE

10 IN. (254 MM)

10 IN.

(254 MM)

HOLE SHOULD MEASURE

10 IN. X 10 IN.

(254 MM X 254 MM)

INSIDE TO INSIDE

Figure 6.3

BEND TABS IN

 

AROUND PIPE

 

3 FASTENERS

 

PER SIDE

 

ATTIC SHIELD INSTALLED

ATTIC SHIELD INSTALLED

BELOW CEILING

ABOVE CEILING

Figure 6.4 Installing the Attic Shield

 

18

Heat & Glo • Crescent II • 2083-902 Rev. N • 7/09

Image 18
Contents What to do if you smell gas Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededInspect Firebox Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Clearances to mantels or other combustibles above applianceTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Measuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One Elbow Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 Min H1 Max V2 Min H2 MaxRestrictor Plate H1 Maximum V1 + V2 MinimumWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Securing and Leveling the ApplianceAttaching Vent to the Firebox Assembly Installing Vent PipeAssembly of Vent Sections Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Termination Cap Roof Pitch Min. FtAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Optional Remote Control Requirements Recommendation for WireConnecting to the Appliance Electrical InformationHeat & Glo Crescent II 2083-902 Rev. N Intermittent Junction Box Installation Installing Flame Control Solenoid Natural Gas OnlyOutside Fit Surround FinishingFacing Requirements For Outside Fit SurroundsInside Facing Dimensions Inside Fit SurroundAccessories Appliance SetupClean the Appliance Remove Shipping MaterialsLog Set Assembly LOGS-Crescent Positioning the LogsSRV2083-185Final placement appearance Replacing Glass Assembly Glass AssemblyRemoving Glass Assembly Replacing Light BulbOperating Instructions Before Lighting ApplianceLighting Appliance IPI Ignition Turn off all electric power to the applianceOn position. The ON/OFF switch may Final inspection byFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsAppliance Dimension Diagram Reference MaterialsLocation Inches Millimeter Vent Components Diagrams DVP vent components Heat & Glo Crescent II Rev. NHorizontal Termination Cap Wall Shield Firestop Heat ShieldHorizontal Termination Cap Kit DRC-RADIUS DVP-HRC, DVP-HRC-SS Part number list on following Log Set AssemblyService Parts Beginning Manufacturing Date AprilService Parts List StockedAt Depot Limited Lifetime Warranty Limited Lifetime Warranty Contact Information

CRESCENT II specifications

The Heat & Glo LifeStyle CRESCENT II is a remarkable gas fireplace that seamlessly combines elegance and functionality, making it an ideal choice for modern homes. Designed to offer both comfort and aesthetic appeal, this fireplace brings warmth and sophistication to any living space.

One of the main features of the CRESCENT II is its sleek, contemporary design. The fireplace boasts a unique crescent-shaped front that provides an expansive view of the flames, allowing for a captivating visual experience. Its clean lines and minimalistic aesthetic make it a striking centerpiece for both traditional and modern interiors.

Equipped with advanced Intellifire technology, the CRESCENT II ensures a hassle-free experience. This innovative system offers a reliable ignition process, allowing users to start their fireplace with the push of a button. The random flame pattern, an essential characteristic of this model, provides a natural and dynamic fire experience that enhances the ambiance of any room.

The Heat & Glo LifeStyle CRESCENT II also prioritizes efficiency. It features a powerful heating capacity and a balanced flue system that allows for versatile installation options. This makes it suitable for various home layouts while ensuring that heat distribution is optimized. Users can enjoy the cozy warmth of their fireplace without compromising on efficiency or air quality.

With customizable options, homeowners can tailor the firebox to their preferences. Options include different media choices, such as glass, stones, or logs, allowing for personalization that matches individual styles. The CRESCENT II also offers several finish options, from classic to modern, ensuring that it complements the unique décor of every home.

In addition to its aesthetic appeal, the CRESCENT II emphasizes safety and convenience. The fireplace includes features like a safety shut-off system and a tempered glass front, protecting both the occupants and the living environment. The easy-to-use remote control allows users to adjust the flame and heat settings conveniently from any location in the room.

Overall, the Heat & Glo LifeStyle CRESCENT II stands out as a sophisticated and efficient gas fireplace option, offering homeowners the perfect combination of style, technology, and safety. With its thoughtful features and customizable design, it creates an inviting atmosphere that enhances the beauty and comfort of any indoor space.