Assembling Minimum Installations (MI) Sections

MI sections are non-unitized so that they can be cut to a certain length. Cut these sections to length from the non- expanded end (see Figure 8.5).

They can then be attached by first connecting the expanded end of the MI inner flue with the inner pipe from the adjacent pipe section and securing with three screws. The expanded portion of the MI inner flue must overlap completely with the unexpanded end of the adjacent pipe section.

The outer flue can then be inserted into the adjacent outer flue expanded end and attached to the next pipe section with three screws. The other end of the MI pipe section can then be attached by fitting another pipe section to it and snapping it together, as normal.

Assembling DVP-12A Slip Sections

The outer flue of the slip section should slide over the outer flue of the pipe section and into (inner flue) the last pipe section (see Figure 8.6) .

Slide together to the desired length, making sure that a 1-1/2 inch outer flue overlap is maintained between the pipe section and slip section.

The pipe and slip section need to be secured by driving two screws through the overlapping portions of the outer flues using the pilot holes (see Figure 8.7).

This will secure the slip section to the desired length and prevent it from separating. The slip section can then be attached to the next pipe section.

If the slip section is too long, the inner and outer flues of the slip section can be cut to the desired length.

Cut from this end

(outer)

Cut from this end

(inner)

Figure 8.5

Pilot hole

Figure 8.6 Slip Section Pilot Holes

Figure 8.7 Screws into Slip Section

Heat & Glo • Crescent II • 2083-902 Rev. N • 7/09

21

Image 21
Contents Hot glass will cause burns What to do if you smell gasHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededInspect Firebox Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseClearances to mantels or other combustibles above appliance Mantel ProjectionsTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Vent Table Key Vent Information and DiagramsMeasuring Standards Use of ElbowsTop Vent Horizontal Termination One Elbow Vent DiagramsTwo Elbows Minimum MaximumV1 Min H1 Max V2 Min H2 Max Top Vent Horizontal Termination Three ElbowsH1 Maximum V1 + V2 Minimum Restrictor PlatePipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Securing and Leveling the Appliance Appliance PreparationAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Roof Pitch Min. Ft Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Connecting to the Appliance Recommendation for WireOptional Remote Control Requirements Electrical InformationHeat & Glo Crescent II 2083-902 Rev. N Intermittent Installing Flame Control Solenoid Natural Gas Only Junction Box InstallationFacing Requirements FinishingOutside Fit Surround For Outside Fit SurroundsInside Fit Surround Inside Facing DimensionsClean the Appliance Appliance SetupAccessories Remove Shipping MaterialsPositioning the Logs Log Set Assembly LOGS-CrescentSRV2083-185Final placement appearance Removing Glass Assembly Glass AssemblyReplacing Glass Assembly Replacing Light BulbBefore Lighting Appliance Operating InstructionsOn position. The ON/OFF switch may Turn off all electric power to the applianceLighting Appliance IPI Ignition Final inspection byFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsLocation Inches Millimeter DVP vent components Heat & Glo Crescent II Rev. N Vent Components DiagramsHorizontal Termination Cap Wall Shield Firestop Heat ShieldHorizontal Termination Cap Kit DRC-RADIUS DVP-HRC, DVP-HRC-SS Service Parts Log Set AssemblyPart number list on following Beginning Manufacturing Date AprilService Parts List StockedAt Depot Limited Lifetime Warranty Limited Lifetime Warranty Contact Information

CRESCENT II specifications

The Heat & Glo LifeStyle CRESCENT II is a remarkable gas fireplace that seamlessly combines elegance and functionality, making it an ideal choice for modern homes. Designed to offer both comfort and aesthetic appeal, this fireplace brings warmth and sophistication to any living space.

One of the main features of the CRESCENT II is its sleek, contemporary design. The fireplace boasts a unique crescent-shaped front that provides an expansive view of the flames, allowing for a captivating visual experience. Its clean lines and minimalistic aesthetic make it a striking centerpiece for both traditional and modern interiors.

Equipped with advanced Intellifire technology, the CRESCENT II ensures a hassle-free experience. This innovative system offers a reliable ignition process, allowing users to start their fireplace with the push of a button. The random flame pattern, an essential characteristic of this model, provides a natural and dynamic fire experience that enhances the ambiance of any room.

The Heat & Glo LifeStyle CRESCENT II also prioritizes efficiency. It features a powerful heating capacity and a balanced flue system that allows for versatile installation options. This makes it suitable for various home layouts while ensuring that heat distribution is optimized. Users can enjoy the cozy warmth of their fireplace without compromising on efficiency or air quality.

With customizable options, homeowners can tailor the firebox to their preferences. Options include different media choices, such as glass, stones, or logs, allowing for personalization that matches individual styles. The CRESCENT II also offers several finish options, from classic to modern, ensuring that it complements the unique décor of every home.

In addition to its aesthetic appeal, the CRESCENT II emphasizes safety and convenience. The fireplace includes features like a safety shut-off system and a tempered glass front, protecting both the occupants and the living environment. The easy-to-use remote control allows users to adjust the flame and heat settings conveniently from any location in the room.

Overall, the Heat & Glo LifeStyle CRESCENT II stands out as a sophisticated and efficient gas fireplace option, offering homeowners the perfect combination of style, technology, and safety. With its thoughtful features and customizable design, it creates an inviting atmosphere that enhances the beauty and comfort of any indoor space.