11 Finishing

A. Mantel Projections

Figure 11.1 shows the minimum vertical and corresponding maxi- mum horizontal dimensions of appliance mantels or other com- bustible projections above the top front edge of the appliance.

Outside Fit Surround

The outside fit surround design is used for facing materials less than 3/4 inch for combustibles, and less than one inch for non-combustibles. The surround is designed to fit flush on finishing materials. Heat & Glo recommends using our cabinets or 1/2 inch finishing materials (see Figure 11.3).

Note: All measurements in inches.

AIR

SPACE

16-1/4 IN.

6-5/16 IN.

CEILING

COMBUSTIBLE

SHEATHING

HEADER BOARD

12

 

 

 

 

11

 

 

 

 

 

 

 

 

10

 

 

 

 

 

9

 

 

 

27 IN.

8

 

 

 

7

 

 

 

 

 

6

 

 

 

 

 

5

 

 

13-3/4 IN.

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

2

 

 

7-3/4 IN.

 

 

1

 

 

 

 

2-3/4 IN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FROM BOTTOM OF HOOD (VISIBLE WITH DOOR REMOVED)

1 in.

Adjust fireplace position if facing material is other than 1/2 inch thick.

CAUTION

For Outside Fit Surrounds

Surface temperatures are hot around fireplace opening.

Finishes may discolor or peel if not suited to temperatures above 200º F.

Figure 11.1 Clearances to mantels or other combustibles above appliance

Top View

½ Inch

MANTEL

LEG

Figure 11.2 Mantel leg or Wall projections (Acceptable on both sides of opening.)

B. Facing Requirements

There are two options to finish the front facing on the fireplace, outside fit surround and inside fit surround.

To cut the arch use the dimensions shown in Figure 11.4.

30-7/16 IN.

22-7/8 IN.

Figure 11.4 Outside Facing Dimensions

32

Heat & Glo • Crescent II • 2083-902 Rev. N • 7/09

Image 32
Contents What to do if you smell gas Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsDesign and Installation Considerations Getting StartedInspect Appliance and Components Tools and Supplies NeededInspect Firebox Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Clearances to mantels or other combustibles above applianceSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Vent Information and Diagrams Vent Table KeyMeasuring Standards Use of ElbowsVent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 Min H1 Max V2 Min H2 MaxRestrictor Plate H1 Maximum V1 + V2 MinimumVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Appliance Preparation Securing and Leveling the ApplianceInstalling Vent Pipe Assembly of Vent SectionsAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Installing Roof Flashing and Vertical Termination Cap Roof Pitch Min. FtAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceOptional Remote Control Requirements Electrical InformationHeat & Glo Crescent II 2083-902 Rev. N Intermittent Junction Box Installation Installing Flame Control Solenoid Natural Gas OnlyFinishing Facing RequirementsOutside Fit Surround For Outside Fit SurroundsInside Facing Dimensions Inside Fit SurroundAppliance Setup Clean the ApplianceAccessories Remove Shipping MaterialsLog Set Assembly LOGS-Crescent Positioning the LogsSRV2083-185Final placement appearance Glass Assembly Removing Glass AssemblyReplacing Glass Assembly Replacing Light BulbOperating Instructions Before Lighting ApplianceTurn off all electric power to the appliance On position. The ON/OFF switch mayLighting Appliance IPI Ignition Final inspection byAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsLocation Inches Millimeter Appliance Dimension DiagramReference Materials Vent Components Diagrams DVP vent components Heat & Glo Crescent II Rev. NHorizontal Termination Cap Kit Horizontal Termination Cap Wall Shield FirestopHeat Shield DRC-RADIUS DVP-HRC, DVP-HRC-SS Log Set Assembly Service PartsPart number list on following Beginning Manufacturing Date AprilAt Depot Service Parts ListStocked Limited Lifetime Warranty Limited Lifetime Warranty Contact Information

CRESCENT II specifications

The Heat & Glo LifeStyle CRESCENT II is a remarkable gas fireplace that seamlessly combines elegance and functionality, making it an ideal choice for modern homes. Designed to offer both comfort and aesthetic appeal, this fireplace brings warmth and sophistication to any living space.

One of the main features of the CRESCENT II is its sleek, contemporary design. The fireplace boasts a unique crescent-shaped front that provides an expansive view of the flames, allowing for a captivating visual experience. Its clean lines and minimalistic aesthetic make it a striking centerpiece for both traditional and modern interiors.

Equipped with advanced Intellifire technology, the CRESCENT II ensures a hassle-free experience. This innovative system offers a reliable ignition process, allowing users to start their fireplace with the push of a button. The random flame pattern, an essential characteristic of this model, provides a natural and dynamic fire experience that enhances the ambiance of any room.

The Heat & Glo LifeStyle CRESCENT II also prioritizes efficiency. It features a powerful heating capacity and a balanced flue system that allows for versatile installation options. This makes it suitable for various home layouts while ensuring that heat distribution is optimized. Users can enjoy the cozy warmth of their fireplace without compromising on efficiency or air quality.

With customizable options, homeowners can tailor the firebox to their preferences. Options include different media choices, such as glass, stones, or logs, allowing for personalization that matches individual styles. The CRESCENT II also offers several finish options, from classic to modern, ensuring that it complements the unique décor of every home.

In addition to its aesthetic appeal, the CRESCENT II emphasizes safety and convenience. The fireplace includes features like a safety shut-off system and a tempered glass front, protecting both the occupants and the living environment. The easy-to-use remote control allows users to adjust the flame and heat settings conveniently from any location in the room.

Overall, the Heat & Glo LifeStyle CRESCENT II stands out as a sophisticated and efficient gas fireplace option, offering homeowners the perfect combination of style, technology, and safety. With its thoughtful features and customizable design, it creates an inviting atmosphere that enhances the beauty and comfort of any indoor space.