Heat & Glo LifeStyle CRESCENT II Horizontal Termination Cap Wall Shield Firestop, Heat Shield

Page 47

B. Vent Components Diagrams (continued)

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required.

8in.

(203 mm)

Heat

Shield

15-1/8 in.

(384 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Term Cap

Minimum

Maximum

 

 

 

 

 

 

 

 

 

 

 

 

Effective Length

Effective Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trap1

3-1/8 in.

4-5/8 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 in.

 

 

 

 

Max

79 mm

117 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(305 mm)

 

Effective

 

5-3/8 in.

9-3/8 in.

 

 

 

 

 

 

 

 

 

Length

Trap2

 

 

 

 

 

 

DVP-TRAP

137 mm

238 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal Termination Cap

 

 

 

 

 

 

Wall Shield Firestop

DVP-TRAP1

Wall Shield Firestop

HSM

DVP-TRAP2

 

 

Heat Shield

 

 

Heat Shield

 

 

 

 

 

DVP-TRAP1

DVP-TRAP2

Horizontal Termination Cap Kit

Horizontal Termination Cap Kit

 

(Shown with optional extended heat shield)

 

Wall Shield Firestop

DVP-TRAP1

Wall Shield Firestop

DVP-TRAP2

DVP90ST

Heat Shield

 

DVP90ST

HSM

 

 

Heat Shield

 

DVP-TRAPK1

DVP-TRAPK2

Horizontal Termination Cap Kit

Horizontal Termination Cap Kit

Figure 16.3 DVP vent components

 

Heat & Glo • Crescent II • 2083-902 Rev. N • 7/09

47

Image 47
Contents Hot glass will cause burns What to do if you smell gasHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsInspect Firebox Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseClearances to mantels or other combustibles above appliance Mantel ProjectionsSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Use of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsMinimum Maximum Vent DiagramsTop Vent Horizontal Termination One Elbow Two ElbowsV1 Min H1 Max V2 Min H2 Max Top Vent Horizontal Termination Three ElbowsH1 Maximum V1 + V2 Minimum Restrictor PlateCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Securing and Leveling the Appliance Appliance PreparationAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Roof Pitch Min. Ft Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Electrical Information Recommendation for WireConnecting to the Appliance Optional Remote Control RequirementsHeat & Glo Crescent II 2083-902 Rev. N Intermittent Installing Flame Control Solenoid Natural Gas Only Junction Box InstallationFor Outside Fit Surrounds FinishingFacing Requirements Outside Fit SurroundInside Fit Surround Inside Facing DimensionsRemove Shipping Materials Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Set Assembly LOGS-CrescentSRV2083-185Final placement appearance Replacing Light Bulb Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsFinal inspection by Turn off all electric power to the applianceOn position. The ON/OFF switch may Lighting Appliance IPI IgnitionAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksLocation Inches Millimeter Appliance Dimension DiagramReference Materials DVP vent components Heat & Glo Crescent II Rev. N Vent Components DiagramsHorizontal Termination Cap Kit Horizontal Termination Cap Wall Shield FirestopHeat Shield DRC-RADIUS DVP-HRC, DVP-HRC-SS Beginning Manufacturing Date April Log Set AssemblyService Parts Part number list on followingAt Depot Service Parts ListStocked Limited Lifetime Warranty Limited Lifetime Warranty Contact Information

CRESCENT II specifications

The Heat & Glo LifeStyle CRESCENT II is a remarkable gas fireplace that seamlessly combines elegance and functionality, making it an ideal choice for modern homes. Designed to offer both comfort and aesthetic appeal, this fireplace brings warmth and sophistication to any living space.

One of the main features of the CRESCENT II is its sleek, contemporary design. The fireplace boasts a unique crescent-shaped front that provides an expansive view of the flames, allowing for a captivating visual experience. Its clean lines and minimalistic aesthetic make it a striking centerpiece for both traditional and modern interiors.

Equipped with advanced Intellifire technology, the CRESCENT II ensures a hassle-free experience. This innovative system offers a reliable ignition process, allowing users to start their fireplace with the push of a button. The random flame pattern, an essential characteristic of this model, provides a natural and dynamic fire experience that enhances the ambiance of any room.

The Heat & Glo LifeStyle CRESCENT II also prioritizes efficiency. It features a powerful heating capacity and a balanced flue system that allows for versatile installation options. This makes it suitable for various home layouts while ensuring that heat distribution is optimized. Users can enjoy the cozy warmth of their fireplace without compromising on efficiency or air quality.

With customizable options, homeowners can tailor the firebox to their preferences. Options include different media choices, such as glass, stones, or logs, allowing for personalization that matches individual styles. The CRESCENT II also offers several finish options, from classic to modern, ensuring that it complements the unique décor of every home.

In addition to its aesthetic appeal, the CRESCENT II emphasizes safety and convenience. The fireplace includes features like a safety shut-off system and a tempered glass front, protecting both the occupants and the living environment. The easy-to-use remote control allows users to adjust the flame and heat settings conveniently from any location in the room.

Overall, the Heat & Glo LifeStyle CRESCENT II stands out as a sophisticated and efficient gas fireplace option, offering homeowners the perfect combination of style, technology, and safety. With its thoughtful features and customizable design, it creates an inviting atmosphere that enhances the beauty and comfort of any indoor space.