Heat & Glo LifeStyle BW36 operating instructions Warranty For HEAT-N-GLO Fireplaces

Page 24

WARRANTY

FOR HEAT-N-GLO FIREPLACES

The limited warranty will not become effective until you have mailed the completed warranty card to HEAT-N-GLO,

A DIVISION OF HEARTH TECHNOLOGIES INC., 20802 Kensington Blvd., Lakeville, MN 55044.

This card must be mailed within 60 days of the fireplace installation.

Subject to the conditions set forth herein, Heat-N-Glo extends the following limited warranty with respect to your Heat-N-Glo fireplace, excluding accessories, Chimney components and Glass Doors.

If Heat-N-Glo is satisfied that any part or portion of the fireplace covered by this warranty is defective in material or workmanship under normal use and service as described in the operating instructions, Heat-N-Glo will take the following actions:

1.Within the first five (5) years from the date of installation, Heat-N-Glo shall, at its option, replace or repair any

such defect in material or workmanship, at Heat-N-Glo’s expense. HEAT-N-GLO SHALL NOT BE RESPONSIBLE FOR ANY OTHER LABOR COSTS, OR EXPENSES, INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

2.During the sixth (6th) through the (10th) years after the date of installation, Heat-N-Glo shall supply replacement parts or parts at no charge, but SHALL NOT BE RESPONSIBLE FOR ANY LABOR, TRANSPORTATION, OR OTHER INDI-

RECT DAMAGES.

3.During the eleventh (11th) through the fifteenth (15th) years after date of installation, Heat-N-Glo will send to you, FOB its factory, replacement parts (if available) at the current minimum wholesale price, but Heat-N-Glo SHALL NOT BE RESPONSIBLE FOR ANY LABOR, TRANSPORTATION OR OTHER INDIRECT DAMAGES.

4.During the first six (6) months after installation, HEAT-N-GLO shall, at its option, replace or repair the Glass Doors and any electrical components, if operation is faulty. (This does not include Glass panels broken during shipment, misuse or careless handling.) After the first six (6) months, HEAT-N-GLO will sell to you, FOB its factory, replacement parts at the current list price, but HEAT-N-GLO SHALL NOT BE RESPONSIBLE FOR ANY LABOR, TRANSPORTATION OR OTHER INDIRECT DAMAGES. IF GLASS DOORS OTHER THAN FACTORY DOORS ARE USED ALL WARRANTY AND LIABILITY ON THE FIREPLACE IS VOIDED.

Heat-N-Glo may discharge its entire warranty liability by refunding the price of the product.

Products made by other manufacturers, sold with the fireplace or thereafter are not covered by this limited warranty.

This limited warranty will be void if the fireplace is not installed according to the installation instructions. The limited warranty also is void if the fireplace is not operated, at all times, according to the operating instructions furnished. The limited warranty will also be void if the fireplace is removed from the place originally installed.

EXCEPT TO THE EXTENT PROVIDED BY LAW, NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND NO IMPLIED WARRANTIES SHALL APPLY TO THE FIREPLACE AFTER THE ABOVE LIMITED WARRANTY HAS EXPIRED.

In states that do not allow limitations on how long implied warranty lasts, or do not allow exclusion of indirect damages, those limitations or exclusions may not apply to you. You may also have additional rights not covered in this limited warranty.

HEAT-N-GLO reserves the right to make changes at anytime, without notice, in design, material, specifications and prices and the right to dis- continue styles and products.

UNDERWRITERS LABORATORIES FILE NO. MH5850

No one builds a better fire

4-00

24

30491 REV D

Image 24
Contents Woodburning Fireplace Installation & Operating Instructions For Residential USEPlease Retain this Manual for Future Reference Listings and Code Approvals Description of the Fireplace SystemFireplace/Integral Grate Chimney System Hearth Extension Glass Doors Heat Circulating FansFireplace System Components HTI Catalog # DescriptionAS8 Integral Grates Insulated DuctID4 Outside AIR KIT Uninsulated DuctChimney Sections Chimney Stabilizer OFFSETS/RETURNS HTI CAT.#Firestop Spacers Roof Flashing Chimney Bracket Joint BandChimney Terminal Caps & Vent Sections Round Terminal CAPWith Storm Collar Square Terminal CAPPRE-INSTALLATION Preparation Fireplace Locations and Space RequirementsWithout Outside AIR With Outside AIR CAT. #Framing the Fireplace Hearth Extensions Factory-Built Hearth ExtensionUsing Offsets and Returns Chimney RequirementsSIDEWALLS/SURROUNDS MantelOffset Chart SL306 SL312 SL318 SL324 SL336 SL348 Chimney Offset/ReturnChimney Height REQUIREMENTS. Above the roof line Determining the Number of Chimney Sections RequiredPositioning the Fireplace Placing the Protective Metal Hearth StripsLeveling the Fireplace Positioning the Metal StripsInstalling the Firestop Spacers Assembling Chimney SectionsInstalling an AS8 Double-checking the Chimney Assembly Securing the Chimney SystemMarking the Exit Point of the Roof Installing Roof Flashing optional Installing an Outside Combustion Air KitAssembling the Chimney Sections Outside Air LocationConstructing a Chase Installing a Terminal Cap on a Chase Enclosed Chimney Chase AssemblyMaterials for the Chase Installing a Terminal Cap Operating InstructionsEdges are SHARP! Hand PRO Tection is Recommended Sectional View of Fireplace Recommended Operating Positions of DoorsBW36 Series Woodburning Fireplace Terminal Caps Warranty For HEAT-N-GLO Fireplaces