Heat & Glo LifeStyle BW36 operating instructions Operating Instructions, Installing a Terminal Cap

Page 20

No one builds a better fire

BW36 SERIES WOODBURNING FIREPLACE

18"

MAX.

DISTANCE

TR342

TERMINAL CAP

CHASE TOP

UPPERMOST

CHIMNEY

SECTION

It is extremely important that the fire be super- vised whenever the fireplace is in use. It is also recommended that an annual inspection be per- formed on the fireplace system to determine if the flue system needs to be cleaned, or as in the case of any appliance, if minor repairs are required to maintain the system in top operating condition.

INTENDED USAGE. This factory-built fire- place is intended for use with either solid fuel (firewood) or a decorative gas appliance that has been tested and listed to the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSI Z21.60. When oper- ating your fireplace, the flue damper must be in the open position.

Figure 22

Installing a Terminal Cap

H.OPERATING INSTRUCTIONS

NOTICE:

SAVE AND PASS THESE OPERATING

INSTRUCTIONS AND THE INSTALLATION

INSTRUCTIONS TO SUBSEQUENT

OWNERS. THE INFORMATION

PROVIDED IS INTENDED TO NOTIFY

AND WARN THEM ABOUT MAKING

UNSAFE FUTURE MODIFICATIONS SUCH

AS THE ADDITION OF SHELVES OR THE

USE OF UNAUTHORIZED PARTS AND

REPAIRS.

CAUTION:

EDGES ARE SHARP! HAND PRO-

TECTION IS RECOMMENDED.

This fireplace is intended to operate as a supplemen- tal heat source for a single room. It is not designed to function as a primary heat source.

Fireplaces, as well as other woodburning appliances, have been used safely for many years. It has been our experience that most problems are caused by improper installation and operation of the unit. Make certain that installation and operation of the fireplace system is in accordance with these instructions.

4-00

20

This fireplace was not tested and listed for use with an unvented gas log heater. Do not install an unvented gas log heater in this fireplace and operate it with the flue damper in the full closed position unless the unvented gas log has been specifically tested and listed for use in this fire- place by Underwriters Laboratories Inc. Use of an unvented gas log heater in this factory-build fireplace may create a fire hazard that can result in a structure fire.

WARNING!

DO NOT OPERATE THIS FIREPLACE WITH THE FLUE DAMPER IN THE CLOSED POSI- TION. COMBUSTION PRODUCTS MUST VENT UP THE CHIMNEY SYSTEM TO PRE- VENT CARBON MONOXIDE POISONING, AND TO PREVENT HOT COMBUSTION GASES FROM CONTACTING AND OVER- HEATING COMBUSTIBLE SURFACES. FAILURE TO OPERATE THIS FIREPLACE WITH THE DAMPER IN THE OPEN POSI- TION MAY RESULT IN ASPHYXIATION OR A STRUCTURE FIRE.

CAUTION:

FIREPLACE OPERATION DOES RE- QUIRE AIR. DO NOT TAKE AIR FROM OTHER FUEL BURNING APPLIANCES WHICH CAN RESULT IN IMPROPER VENTING (SMOKING) OR AIR DILUTION. ALWAYS PRO- VIDE ADEQUATE MAKE-UP AIR.

30491D

Image 20
Contents Woodburning Fireplace Installation & Operating Instructions For Residential USEPlease Retain this Manual for Future Reference Listings and Code Approvals Description of the Fireplace SystemFireplace/Integral Grate Chimney System Hearth Extension Glass Doors Heat Circulating FansFireplace System Components HTI Catalog # DescriptionAS8 Integral Grates Insulated DuctID4 Outside AIR KIT Uninsulated DuctChimney Sections Chimney Stabilizer OFFSETS/RETURNS HTI CAT.#Firestop Spacers Roof Flashing Chimney Bracket Joint BandChimney Terminal Caps & Vent Sections Round Terminal CAPWith Storm Collar Square Terminal CAPPRE-INSTALLATION Preparation Fireplace Locations and Space RequirementsWithout Outside AIR With Outside AIR CAT. #Framing the Fireplace Hearth Extensions Factory-Built Hearth ExtensionUsing Offsets and Returns Chimney RequirementsSIDEWALLS/SURROUNDS MantelOffset Chart SL306 SL312 SL318 SL324 SL336 SL348 Chimney Offset/ReturnChimney Height REQUIREMENTS. Above the roof line Determining the Number of Chimney Sections RequiredPositioning the Fireplace Placing the Protective Metal Hearth StripsLeveling the Fireplace Positioning the Metal StripsInstalling the Firestop Spacers Assembling Chimney SectionsMarking the Exit Point of the Roof Installing an AS8 Double-checking the Chimney AssemblySecuring the Chimney System Installing Roof Flashing optional Installing an Outside Combustion Air KitAssembling the Chimney Sections Outside Air LocationConstructing a Chase Materials for the Chase Installing a Terminal Cap on a Chase Enclosed ChimneyChase Assembly Edges are SHARP! Hand PRO Tection is Recommended Installing a Terminal CapOperating Instructions Sectional View of Fireplace Recommended Operating Positions of DoorsBW36 Series Woodburning Fireplace Terminal Caps Warranty For HEAT-N-GLO Fireplaces