Figure 10. Standing Pilot Ignition Wiring Diagram
Step 9. Wiring the Fireplace
NOTE: Electrical wiring must be installed by a licensed electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS TO PREVENT ACCIDENTAL FIREPLACE OPERATION.
For Standing Pilot Ignition Wiring
Appliance Requirements
•This appliance DOES NOT require
!WARNING: DO NOT CONNECT
Optional Accessories
Optional fan and remote control kits require that
Wall Switch
Position the wall switch in the desired position on the wall. An assembly of 18 ft of 20 AWG is provided with the fireplace to connect the wall switch to the appliance. Instead of the sup- plied assembly, wire with a length of 25 ft or less and a gauge of 20 AWG through 14 AWG is acceptable. The wire needs a jacket with a temperature rating of 140oF (60oC) or higher. At the appliance connect the wire to the ON/OFF switch pigtails.
WARNING: DO NOT CONNECT
!TO THE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED.
CAUTION: LABEL ALL WIRES PRIOR TO DISCON- NECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.
| VARIABLE SPEED CONTROL |
|
|
|
| NOTE: IF ANY OF THE ORIGINAL WIRE |
|
|
| AS SUPPLIED WITH THE APPLIANCE |
|
BLK | BLK | MUST BE REPLACED, IT MUST BE |
|
JUNCTION BOX | REPLACED WITH TYPE 105OC RATED WIRE. |
| |
|
|
| |
BLK | BLK | BLOWER RECEPTACLE |
|
|
| BLK |
|
BLK |
|
|
|
| BLK |
|
|
| WHT | WHT |
|
| BLK |
|
|
TEMPERATURE | GROUND |
|
|
|
|
| |
SENSOR SWITCH |
|
|
|
|
| BLOWER | |
| GRN |
|
|
| BLK | WHT |
|
| BLOWER | SENSOR | |
|
| SWITCH |
Figure 11. Fan Wiring Diagram
“FAN”
RECEPTACLE SPEED CONTROL
16 | Heat & Glo • |