OPERATION

b-5

 

 

 

WIRE FEED SPEED UNITS

To change the wire feed speed units:

Rotate the WFS knob to the left to use “inches/minute” for the wire feed speed units.

US

O O A

V

LN-25™ PIPE, CCC

O O WFS

WFS CALIbRATION WITH DIGITAL METERS

To calibrate the wire feed speed, before entering the set-up menu. When first entering WFS Calibration, the calibration factor displayed is based upon the position of the knob and does not reflect the actual calibration factor stored in memory.

Rotate the WFS knob to the right to use “meters/minute” for the wire feed speed units.

Then rotate the WFS knob to the 12 o’clock position.

EU ro

O O A

V

LN-25™ PIPE, CCC

O O WFS

Set the display to the desired wire feed speed (example: 400 inches per minute)

Measure the actual wire feed speed (example: 405 inches per minute)

While in the set-up menu, adjust the calibration factor as follows:

Press the set-up button again to enter the Run-In menu.

RUN-IN

“Run-in” refers to the wire feed speed during the time from when the trigger is pulled to when an arc is struck.

When Run-in is “ON”, the wire feed speed is reduced until an arc is struck. Factory setting is Run-In “OFF”.

Model

Run-in Wire Feed Speed

LN-25™ PIPE

50 in/min

Actual WFS =Calibration Factor

Example 405

=1.01

Set WFS

400

 

Press the set-up button.

When Run-in is “OFF”, the wire feed speed is the same as the welding wire feed speed. Turn Run-In “OFF” for fast, crisp starts, especially when running with .035 or .045 (0.9 or 1.2mm) solid steel wires at high wire feed speeds.

To change the Run-in setting:

Rotate the WFS knob to the left to turn Run-In OFF.

r un OFF

O O A

V

LN-25™ PIPE, CCC

O O WFS

Rotate the WFS knob to the right to turn Run-In ON.

Then rotate the WFS knob to the 12 o’clock position.

runOn

O O A

V

LN-25™ PIPE, CCC

O O WFS

Press the set-up button again to enter the WFS cali- bration menu.