Lincoln Electric IM10092 manual Output Problems

Models: IM10092

1 38
Download 38 pages 57.04 Kb
Page 32
Image 32

E-3

TROUbLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PRObLEMS

(SYMPTOMS)

POSSIbLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Output Problems

 

The feeder does power up - no dis-

1.

The work sense lead is discon-

1.

Connect the work sense lead to

 

play, no cold feed.

 

nected or is a poor electrical con-

 

the work in a location free of dirt,

 

 

 

nection. (Across the arc models)

 

rust and paint.

 

 

2.

The power source is OFF.

2.

Turn ON the power source.

 

 

3.

The circuit breaker for the wire

3.

Reset the circuit breakers.

 

 

 

feeder on power source have

 

 

 

 

 

 

tripped. (control cable models)

 

 

 

 

 

4.

The control cable may be loose or

4.

Tighten, repair or replace the con-

 

 

 

damaged. (control cable models)

 

trol cable.

 

 

 

 

 

 

 

 

The wire feeder power up but there

1.

The contactor coil connections are

1.

Verify the contactor coil connec-

 

is no output when the trigger is

 

loose.

 

tions.

 

pulled. The shielding gas is flowing

2.

The contactor has failed.

2.

Replace the contactor.

 

and the drive rolls turn.

 

 

 

 

 

 

 

 

 

 

 

 

No shielding gas.

1.

The gas supply is OFF or empty.

1.

Verify the gas supply is ON and

 

 

 

 

 

flowing.

 

 

2.

The gas hose is cut or crushed.

2.

Route the gas hose so it avoids

 

 

 

 

 

sharp corners and make sure

 

 

 

 

 

nothing is on top of it. Repair or

 

 

 

 

 

replace damaged hoses.

 

 

3.

The flow meter valve is closed.

3.

Open the flow meter valve.

 

 

4.

Dirt or debris is in the solenoid.

4.

Apply filtered shop at 80psi to the

 

 

 

 

 

solenoid to remove dirt.

 

 

5.

There is a loose solenoid connec-

5.

Remove the cover and check that

 

 

 

tion.

 

all connections are in good condi-

 

 

 

 

 

tion.

 

 

6.

The solenoid has failed.

 

 

 

 

 

 

 

 

 

 

 

Inconsistent wire feeding or wire not

1.

The gun cable is kinked and/or

1.

Keep the gun cable as straight as

 

feeding but drive rolls turning.

 

twisted.

 

possible. Avoid sharp corners or

 

 

2.

The wire is jammed in the gun and

 

bends in the cable.

 

 

2.

Remove the gun from the wire

 

 

 

cable.

 

feeder and pull the jammed wire

 

 

 

 

 

out of the gun and cable.

 

 

3.

The gun liner is dirty or worn.

3.

Blow dirt out of the liner with low

 

 

 

 

 

pressure (40psi or less). Replace

 

 

 

 

 

the liner if worn.

 

 

4.

The electrode is rusty or dirty.

4.

Use only clean electrode. Use

 

 

 

 

 

quality electrode, like L-50 or L-56

 

 

 

 

 

from Lincoln Electric.

 

 

5.

The contact tip is partially melted

5.

Replace the contact tip.

 

 

 

or has spatter.

 

 

 

 

 

6.

Improper gun liner, tip, drive rolls

6.

Verify the proper parts are

 

 

 

and/or inner wire guide.

 

installed.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.