To correct this, remove the thermostat from the wall and remove the battery for at least two minutes. After reinstalling the battery, the thermostat will revert to the factory pre- set program until you reprogram the ther- mostat. If you don’t want to reprogram the
thermostat immediately, press | SYSTEM | until |
HEAT/EMER/OFF/ | ||
| COOL/AUTO |
|
OFF is displayed and replace the thermo-
stat on the wall. Then press PRGMRUN to begin the factory preset program.
To prevent further static discharge prob- lems, touch another object to release static
7.Why won’t the setpoint temperature go to the temperature I want?
In the AUTO mode, the highest heating
setpoint temperature you select must be at least 1°F lower than the lowest cooling
setpoint temperature you select (for ex- ample, if 70°F is your lowest selected cool-
ing temperature, you cannot select a heat- ing temperature any higher than 68°F). If such a conflict exists, set the lowest cooling temperature higher in order to set the heat- ing temperature higher. To set a lower cool- ing temperature, you must select a lower heating temperature. See PROGRAMMING YOUR THERMOSTAT.
35