White Rodgers 37-6753B specifications Troubleshooting, Reset Operation

Page 11

TROUBLESHOOTING

Reset Operation

Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings.

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.

Note: Be sure to review the installer configuration menu settings.

To reset the programming, clock and configuration settings, pressand and the SYSTEM button simultaneously. The thermostat should go blank and then all segments will be displayed momentarily.

Symptom

Possible Cause

Corrective Action

 

 

 

 

No Heat/No Cool/No Fan

1.

Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2.

Furnace power switch to OFF.

Turn switch to ON.

 

3.

Furnace blower compartment door or

Replace door panel in proper position to engage safety

 

 

panel loose or not properly installed.

interlock or door switch.

 

4.

Loose connection to thermostat or system.

Tighten connections.

 

 

 

 

No Heat

1.

Pilot light not lit.

Re-light pilot.

 

2.

Furnace Lock-Out Condition. Heat

Many furnaces have safety devices that shut down when a

 

 

may also be intermittent.

lock-out condition occurs. If the heat works intermittently

 

 

 

contact the furnace manufacturer or local HVAC service

 

 

 

person for assistance.

 

3.

Heating system requires service or

Diagnostic: Set SYSTEM Switch to HEAT and raise the

 

 

thermostat requires replacement.

setpoint above room temperature. Within a few seconds

 

 

 

the thermostat should make a soft click sound. This sound

 

 

 

usually indicates the thermostat is operating properly. If

 

 

 

the thermostat does not click, try the reset operation listed

 

 

 

above. If the thermostat does not click after being reset

 

 

 

contact your heating and cooling service person or place

 

 

 

of purchase for a replacement. If the thermostat clicks,

 

 

 

contact the furnace manufacturer or a HVAC service

 

 

 

person to verify the heating is operating correctly.

 

 

 

 

No Cool

1.

Cooling system requires service or

Same as diagnostic for No Heat condition except set the

 

 

thermostat requires replacement.

thermostat to COOL and lower the setpoint below the

 

 

 

room temperature. There may be up to a five minute delay

 

 

 

before the thermostat clicks in Cooling.

 

 

 

 

Heat, Cool or Fan

1.

Possible short in wiring.

Check each wire connection to verify they are not shorted

Runs Constantly

2.

Possible short in thermostat.

or touching together. No bare wire should stick out from

 

3.

Possible short in heat/cool/fan system.

under terminal block. Try resetting the thermostat as

 

4.

FAN Switch set to Fan ON.

described above. If the condition persists the manufacturer

 

 

 

of your system or service person can instruct you on how

 

 

 

to test the Heat/Cool system for correct operation. If the

 

 

 

system operates correctly, replace the thermostat.

 

 

 

 

Thermostat Setting &

1.

Thermostat thermometer setting

The thermometer can be adjusted +/- 4 degrees. See

Thermostat Thermometer

 

requires adjustment.

Temperature Display Adjustment in the Configuration

Disagree

 

 

Menu section.

 

 

 

 

Furnace (Air Conditioner)

1.

The location of the thermostat and/or

Digital thermostats provide precise control and cycle faster

Cycles Too Fast or Too Slow

 

the size of the Heating System may

than older mechanical models. The system turns on and

(narrow or wide

 

be influencing the cycle rate.

off more frequently but runs for a shorter time so there is

temperature swing)

 

 

no increase in energy use. If you would like an increased

 

 

 

cycle time, choose SL for slow cycle in the Configuration

 

 

 

menu, step 7 (heat) or 8 (cool). If an acceptable cycle rate

 

 

 

is not achieved, contact a local HVAC service person for

 

 

 

additional suggestions.

 

 

 

 

Forgot Keypad

 

 

Press the menu button (button will disappear) and hold in

Lockout Code

 

 

for 20 seconds. This unlocks the thermostat.

 

 

 

 

11

Image 11
Contents Save these instructions for future use SpecificationsApplications Battery Location InstallationWiring Connections Installing New ThermostatHome Screen Description Programming and Configuration ItemsThermostat Quick Reference Configuration Menu INSTALLER/CONFIGURATION MenuMode Fast rate Setting is 99F. It can be changed between 62F Programming Operating Your ThermostatAutomatic Schedule Programming Tip Copy ProgramEnter the Heating Program Enter the Cooling ProgramWorksheet for Re-Programming 5+1+1 and 7 Day Program Energy Saving Factory Pre-ProgramPlanning Your Program Important Dual Fuel Temperature Setpoint Wired Remote Temperature SensingWeight of Remote Reading Reset Operation TroubleshootingSt. Louis, Missouri

37-6753B specifications

The White Rodgers 37-6753B is a high-performance thermostat designed to cater to the needs of both residential and light commercial applications. Recognized for its user-friendly interface and advanced features, this thermostat offers an ideal blend of functionality and sophistication.

One of the standout features of the 37-6753B is its ability to manage both heating and cooling systems effectively. It supports a wide range of HVAC configurations, including single-stage and multi-stage heat pumps, gas furnaces, and air conditioning systems. This versatility makes it an excellent choice for various settings, ensuring optimal comfort year-round.

The thermostat boasts a large, easy-to-read display that enhances usability. Users can quickly view and adjust temperature settings, making it simple to achieve their desired indoor climate. The intuitive button layout also facilitates seamless navigation through programming options and system settings.

A key technological advantage of the White Rodgers 37-6753B is its programmable capabilities. Users can create customized schedules to optimize energy use throughout the day. With the ability to set different temperature profiles for weekdays and weekends, the thermostat can significantly reduce energy consumption without sacrificing comfort.

Another notable feature is the inclusion of advanced temperature averaging technology. This feature ensures that the heating and cooling systems operate efficiently by measuring the temperature in multiple locations within a home. As a result, it can prevent hot or cold spots, leading to a more uniform indoor climate.

The 37-6753B is also equipped with a filter change indicator. This feature alerts users when it’s time to replace or clean the air filter in their HVAC system, promoting better air quality and system performance. Regular maintenance helps extend the lifespan of the heating and cooling units.

For added convenience, the thermostat can be powered either by batteries or through a C-wire connection, allowing for flexibility depending on your existing system's setup. The compact design also makes it easy to install, even for those with minimal technical expertise.

In summary, the White Rodgers 37-6753B thermostat is a technologically advanced solution for managing indoor climates efficiently. Its programmable features, temperature averaging technology, and user-friendly design make it a standout choice for homeowners and light commercial users alike, ensuring reliable temperature control and energy savings.