Number Description

E58-45 45° Elbow, Galvanized

E58-90 90° Elbow, Galvanized

FSE58-45 45° Starter Elbow (Dura Vent to FMI Pipe)

FP-58 Firestop Plate

WF-58 Wall Firestop, Galvanized

RF-58-6 Roof Flashing - 0 to 6/12 Pitch, Galvanized

RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch, Galvanized

S-58 Vinyl Siding Standoff,

Galvanized

VT-58 Vertical Round Termination, Galvanized

HHT-58 High WInd Round Horizontal Termination Kit, Galvanized

HTS-58 Square Horizontal Termination, Galvanized

HHTK-58 High Wind Round Horizontal Termination Kit

(Includes Round Termination, Wall Firestop, 45° Elbow)

ST-58-14 14" Snorkel Termination,

Galvanized

ST-58-36 36" Snorkel Termination,

Galvanized

SF-58 Stucco Flashing - For use with HTS-58

VR-58 Vertical Restrictor, Galvanized WS-58 Wall Strap

SC-58 Storm Collar, Galvanized

CS-58 Cathedral Ceiling Support

Installation

WALL SWITCH INSTALLATION

The electronic version uses a 24 VAC current sup- plied from a transformer mounted on the ignition module and is prewired for easy connection to a wall switch (see Figure 31). The millivolt version uses a self generated millivolt current that allows you to activate the gas control valve directly with- out the use of normal household electricity (see Figure 32). Both versions are supplied with a wall switch kit for ready connection and mounting.

WARNING: Do not wire re- mote wall switch to main power supply (Standard 120V house- hold current).

1.To remove the louvers, simultaneously pull both top end spring latches towards the center of the appliance until they are disengaged from locating holes. Repeat for bottom spring latches and pull louvers outward. Reverse the procedure to install louvers back onto the ap- pliance (see Figure 33, page 19).

2.Connect the 18 gauge wires from wall switch to the gas control valve terminals marked TH and TPTH or to the ignition module using the pigtails and wire nut connectors supplied with the appliance.

Route 24V (Supplied)

Wall Switch

Through Electrical

 

Conduit Bushing

 

(Supplied)

Electrode

Make Connections

 

 

with Wirenuts

 

 

 

(Supplied)

 

(Back

 

 

 

 

 

 

 

 

View)

Transformer

 

 

 

 

 

 

G

P.

 

 

 

N

 

 

 

D V2 L1 IND TS SI

SW V1

 

Plug 120V AC

Ignition

 

To Receptacle

18 AWG

 

 

Control

 

 

Red Wire

 

 

Module

 

 

 

G

 

P.

 

 

N V2 L1

IND TS SI

SW V1

 

 

D

 

 

 

 

Figure 31 - Wall Switch Wiring Diagram,

Electronic Units

6AI

 

 

7

TH

Wall Switch

 

 

 

TP

(Supplied)

 

TPTH

To

 

 

 

 

Thermopile

 

 

ILOT

 

 

 

P

 

O N

 

16AI

 

T

 

 

 

O

 

7

TH

L

 

I

 

 

 

P

L

I

 

O

O

H

TP

FF

 

 

E

A

 

TPTH

 

 

Route Millivolt Wires

(Back

(Supplied) Through Gas

View)

Line Conduit Sleeve

 

Figure 32 - Wall Switch Wiring Diagram,

Millivolt Units

Note: If any of the original wire supplied must be replaced, use type 18 AWG-105° C (25 feet length maximum) or equivalent.

18

www.desatech.com

112108-01C

Image 18
Contents What to do if YOU Smell GAS Right Side Corner Model ShownTable of Contents Safety InformationSafety Information High traffic areas TOP View Back View DimensionsPre-Installation Preparation Right Side Front ViewClearances Mantel ClearancesFraming Alternate Gas Supply Location General Venting Vent Termination ClearancesMinimum Clearances for Termination Cap Venting Installation Instructions Installation PrecautionsInstallation Planning Installation for horizontal termination Installing Vent System in a ChaseVent Pipe Connections Horizontal Venting Venting with Two 90 ElbowsInstallation for vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Cathedral Ceiling Support Box InstallationVertical Rigid Venting Configuration Using One 90 Elbow Venting with One 90 ElbowVertical Venting High altitude installationParts list for Desa venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionInstallation Wall Switch InstallationElectrical Hookup for optional blower accessory Optional Wireless hand-held Remote Control InstallationGAS Line HOOK-UP Removed from ignition control circuit forGas Supply Testing Not OvertightenInstalling Log Set ON/OFFPilot/Electrode Assembly Adjustment Decorative FacingBurner Flame Adjustment Burner RemovalCleaning Maintenance Cleaning and Replacing Glass DoorFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Operating Fireplace To Turn OFF GAS To ApplianceSpecifications Service HintsTechnical Service Replacement PartsTroubleshooting Problem Possible Cause RemedyTroubleshooting Wiring Diagrams See Wiring DiagramsParts Accessories Pilot AssemblySkytech Remote Control KIT Blower kit Grate End Glass Assembly Peninsula OnlyScreen Assembly Burner AssemblY Piezo Ignitor End Louver Kit Peninsula OnlyLOG SET Refractory Pieces Side Door Assembly 27200 CeramicIgnition Control High Voltage Cable112108-01C Warranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace

DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP, DVF36TCR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP, (V)DVF36TCRP(E), (V)DVF36TCLP(E) specifications

The Desa DVF36TCR and DVF36TCL are part of a distinguished line of vent-free gas fireplaces designed to provide warmth and ambiance without the complexity of standard venting systems. These models, including DVF36TCRP, DVF36TCLP, and their electric variants (V)DVF36TCRP(E) and (V)DVF36TCLP(E), incorporate cutting-edge technology, ensuring efficient heating solutions that suit various home aesthetics and requirements.

One of the primary features of the DVF36TCR and DVF36TCL is their minimalist design, which allows for flexibility in installation. The option to choose between traditional and contemporary styles means that homeowners can select a model that complements their existing decor. The DVF36TCR boasts a classic design, while the DVF36TCL presents a more modern aesthetic, appealing to a broad range of personal styles.

Energy efficiency is another hallmark of these models. The Desa gas fireplaces utilize advanced burner technology that maximizes heat output while minimizing gas consumption. This efficiency not only translates to lower energy bills but also a reduced environmental impact, making these fireplaces a responsible choice for homeowners.

The DVF series also places a strong emphasis on safety. Each model is equipped with an oxygen depletion sensor (ODS) that automatically shuts off the gas supply if oxygen levels in the room drop below safe levels, providing peace of mind for families. Additionally, the built-in safety features, including a flame monitoring system, ensure a safe and reliable heating experience.

For those seeking convenience, the Desa models are compatible with remote controls and wall-mounted thermostats, allowing users to easily adjust heat settings without leaving the comfort of their couch. This versatility is particularly appealing in colder months when warmth is a priority.

Moreover, the fireplaces come with various media options, such as pebble beds or log sets, enhancing the visual appeal of the flames. The ambiance created by these fireplaces is not only about heat but about creating a cozy atmosphere that draws family and friends together.

In summary, the Desa DVF36TCR, DVF36TCL, and their respective models offer a unique blend of style, efficiency, and safety. With features aimed at enhancing user experience and optimizing home heating, these fireplaces stand out as leading options for those looking to add both warmth and elegance to their living spaces. Whether opting for gas or one of the electric versions, homeowners can trust in the quality and innovation present in the Desa DVF series.