Desa (V)DVF36TCLP(E), (V)DVF36TCRP(E) installation manual High traffic areas

Page 4

Safety information

Continued

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the appliance.

Do not use this fireplace to cook food or burn paper or other flam- mable material.

This fireplace reaches high tem- peratures. Keep children and adults away from hot surface to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow sur- face to cool before touching.

Carefully supervise young chil- dren when they are in the room with fireplace.

Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor or liquids. Do not run fireplace where these are used or stored.

1.For propane/LP fireplace, do not place pro- pane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions

if you cannot reach you gas supplier, call the fire department.

3.Never install the fireplace

in a recreational vehicle

in windy or drafty areas where curtains or other combustible (flammable) objects can make contact with the fireplace front

in high traffic areas

4.Turn fireplace off and let cool before servicing, installing or repairing. Only a qualified service person should install, service or repair this fireplace. Have fireplace inspected annually by a qualified service person.

5.You must keep control compartments, burn- ers and circulating air passages clean. More frequent cleaning may be needed due to ex- cessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace.

6.Have venting system inspected annually by a qualified service person. If needed, have vent- ing system cleaned or repaired. See Operating Guidelines and Maintenance Instructions, page 25.

7.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate.

8.Do not use fireplace if any part has been ex- posed to or under water. Immediately call a qualified service person to arrange for replace- ment of the unit.

9.Do not operate fireplace if any log is broken.

10.Do not operate fireplace with glass door removed, cracked or broken.

11.Provide adequate clearances around air openings.

12.Fireplaces with the suffix of -HA have been designed to operate at altitudes of 4000 feet and above. For horizontal installations above 2,000 feet, it is recommened that a 12" exten- sion pipe be added before starter elbow (see High Altitude Installation, page 17).

www.desatech.com112108-01C

Image 4
Contents What to do if YOU Smell GAS Right Side Corner Model ShownTable of Contents Safety InformationSafety Information High traffic areas Dimensions Pre-Installation PreparationTOP View Back View Right Side Front ViewMantel Clearances ClearancesFraming Alternate Gas Supply Location General Venting Vent Termination ClearancesMinimum Clearances for Termination Cap Installation Precautions Venting Installation InstructionsInstallation Planning Installation for horizontal termination Installing Vent System in a ChaseVent Pipe Connections Horizontal Venting Venting with Two 90 ElbowsInstallation for vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Cathedral Ceiling Support Box InstallationVertical Rigid Venting Configuration Using One 90 Elbow Venting with One 90 ElbowHigh altitude installation Parts list for Desa venting kits and componentsVertical Venting Desa 5/8 Pipe & Vent Kits Number DescriptionInstallation Wall Switch InstallationElectrical Hookup for optional blower accessory Optional Wireless hand-held Remote Control InstallationGAS Line HOOK-UP Removed from ignition control circuit forGas Supply Testing Not OvertightenInstalling Log Set ON/OFFPilot/Electrode Assembly Adjustment Decorative FacingBurner Flame Adjustment Burner RemovalCleaning Maintenance Cleaning and Replacing Glass DoorOperating Fireplace For Your Safety Read Before LightingLighting Instructions Operating Fireplace To Turn OFF GAS To ApplianceService Hints Technical ServiceSpecifications Replacement PartsTroubleshooting Problem Possible Cause RemedyTroubleshooting Wiring Diagrams See Wiring DiagramsPilot Assembly Parts AccessoriesSkytech Remote Control KIT Grate End Glass Assembly Peninsula Only Screen Assembly Burner AssemblY Piezo IgnitorBlower kit End Louver Kit Peninsula OnlySide Door Assembly 27200 Ceramic Ignition ControlLOG SET Refractory Pieces High Voltage Cable112108-01C Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP, DVF36TCR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP, (V)DVF36TCRP(E), (V)DVF36TCLP(E) specifications

The Desa DVF36TCR and DVF36TCL are part of a distinguished line of vent-free gas fireplaces designed to provide warmth and ambiance without the complexity of standard venting systems. These models, including DVF36TCRP, DVF36TCLP, and their electric variants (V)DVF36TCRP(E) and (V)DVF36TCLP(E), incorporate cutting-edge technology, ensuring efficient heating solutions that suit various home aesthetics and requirements.

One of the primary features of the DVF36TCR and DVF36TCL is their minimalist design, which allows for flexibility in installation. The option to choose between traditional and contemporary styles means that homeowners can select a model that complements their existing decor. The DVF36TCR boasts a classic design, while the DVF36TCL presents a more modern aesthetic, appealing to a broad range of personal styles.

Energy efficiency is another hallmark of these models. The Desa gas fireplaces utilize advanced burner technology that maximizes heat output while minimizing gas consumption. This efficiency not only translates to lower energy bills but also a reduced environmental impact, making these fireplaces a responsible choice for homeowners.

The DVF series also places a strong emphasis on safety. Each model is equipped with an oxygen depletion sensor (ODS) that automatically shuts off the gas supply if oxygen levels in the room drop below safe levels, providing peace of mind for families. Additionally, the built-in safety features, including a flame monitoring system, ensure a safe and reliable heating experience.

For those seeking convenience, the Desa models are compatible with remote controls and wall-mounted thermostats, allowing users to easily adjust heat settings without leaving the comfort of their couch. This versatility is particularly appealing in colder months when warmth is a priority.

Moreover, the fireplaces come with various media options, such as pebble beds or log sets, enhancing the visual appeal of the flames. The ambiance created by these fireplaces is not only about heat but about creating a cozy atmosphere that draws family and friends together.

In summary, the Desa DVF36TCR, DVF36TCL, and their respective models offer a unique blend of style, efficiency, and safety. With features aimed at enhancing user experience and optimizing home heating, these fireplaces stand out as leading options for those looking to add both warmth and elegance to their living spaces. Whether opting for gas or one of the electric versions, homeowners can trust in the quality and innovation present in the Desa DVF series.