Desa (V)DVF36TCLP(E), (V)DVF36TCRP(E) installation manual Vent Pipe Connections

Page 12

Venting Installation

instructions

Continued

Twist-lock Procedure: The female ends of the pipes and fittings have four locking lugs (in- dentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes and fittings. (All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 10.) Push the pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked. See Figure 14. Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose.

3.Attach vent pipe assembly to the fireplace using twist lock connections. Set fireplace in front of its permanent location to insure minimum clear- ances. Mark the wall for a 10 3/4" square hole (for noncombustible material such as masonry block or concrete, a 8 1/2" diameter hole is acceptable). See Figure 15. The center of the hole should line up with the centerline of the rigid vent pipe. Cut a 10 3/4" x 10 3/4" square hole through combustible exterior wall (8 1/2" diameter hole if noncombustible). Frame as necessary.

Male

Slots

Female

Locking

Lugs

Figure 14 - Vent Pipe Connections

Vent Opening

Combustible Wall

10 3/4" Inside Framing

10 3/4"

 

103/4"

(Framing

4.Noncombustible Exterior Wall: Apply a bead of non-hardening mastic around the outside edge of the vent cap. Position the vent cap in the center of the hole on the exterior wall with the arrow on the vent cap pointing up. Attach the vent cap with four wood screws provided (see Figure 16). Note: Replace the wood screws with appropriate fasteners for stucco, brick, concrete, or other types of siding.

Combustible Exterior Wall: For vinyl siding, stucco, or wood exteriors, a siding standoff must be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging siding materials. Siding materials must be cut to accommodate standoff. Bolt the vent cap to the standoff. Apply non-hardening mastic around outside edge of the standoff. Position the standoff/cap assembly in the center of the square hole and attach to exterior wall with wood screws pro- vided (see Figure 17). The siding standoff must sit flush against the exterior fascia material.

Vent Cap

Wood Screw

Figure 16 - Installing Horizontal Vent Cap

(Noncombustible Exterior)

Cut Siding Away to

Fit Standoff

Wood

Standoff Screw

Vent

Cap

Vent Opening

Detail)

Noncombustible Wall

8 1/2"

Figure 15 - Vent Opening Requirements

Screws

Apply Mastic to All Four Sides

Figure 17 - Installing Siding Standoff

(Combustible Exterior Wall)

12

www.desatech.com

112108-01C

Image 12
Contents What to do if YOU Smell GAS Right Side Corner Model ShownTable of Contents Safety InformationSafety Information High traffic areas Dimensions Pre-Installation PreparationTOP View Back View Right Side Front ViewClearances Mantel ClearancesFraming Alternate Gas Supply Location General Venting Vent Termination ClearancesMinimum Clearances for Termination Cap Venting Installation Instructions Installation PrecautionsInstallation Planning Installation for horizontal termination Installing Vent System in a ChaseVent Pipe Connections Horizontal Venting Venting with Two 90 ElbowsInstallation for vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Cathedral Ceiling Support Box InstallationVertical Rigid Venting Configuration Using One 90 Elbow Venting with One 90 ElbowHigh altitude installation Parts list for Desa venting kits and componentsVertical Venting Desa 5/8 Pipe & Vent Kits Number DescriptionInstallation Wall Switch InstallationElectrical Hookup for optional blower accessory Optional Wireless hand-held Remote Control InstallationGAS Line HOOK-UP Removed from ignition control circuit forGas Supply Testing Not OvertightenInstalling Log Set ON/OFFPilot/Electrode Assembly Adjustment Decorative FacingBurner Flame Adjustment Burner RemovalCleaning Maintenance Cleaning and Replacing Glass DoorFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Operating Fireplace To Turn OFF GAS To ApplianceService Hints Technical ServiceSpecifications Replacement PartsTroubleshooting Problem Possible Cause RemedyTroubleshooting Wiring Diagrams See Wiring DiagramsParts Accessories Pilot AssemblySkytech Remote Control KIT Grate End Glass Assembly Peninsula Only Screen Assembly Burner AssemblY Piezo IgnitorBlower kit End Louver Kit Peninsula OnlySide Door Assembly 27200 Ceramic Ignition ControlLOG SET Refractory Pieces High Voltage Cable112108-01C Warranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace

DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP, DVF36TCR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP, (V)DVF36TCRP(E), (V)DVF36TCLP(E) specifications

The Desa DVF36TCR and DVF36TCL are part of a distinguished line of vent-free gas fireplaces designed to provide warmth and ambiance without the complexity of standard venting systems. These models, including DVF36TCRP, DVF36TCLP, and their electric variants (V)DVF36TCRP(E) and (V)DVF36TCLP(E), incorporate cutting-edge technology, ensuring efficient heating solutions that suit various home aesthetics and requirements.

One of the primary features of the DVF36TCR and DVF36TCL is their minimalist design, which allows for flexibility in installation. The option to choose between traditional and contemporary styles means that homeowners can select a model that complements their existing decor. The DVF36TCR boasts a classic design, while the DVF36TCL presents a more modern aesthetic, appealing to a broad range of personal styles.

Energy efficiency is another hallmark of these models. The Desa gas fireplaces utilize advanced burner technology that maximizes heat output while minimizing gas consumption. This efficiency not only translates to lower energy bills but also a reduced environmental impact, making these fireplaces a responsible choice for homeowners.

The DVF series also places a strong emphasis on safety. Each model is equipped with an oxygen depletion sensor (ODS) that automatically shuts off the gas supply if oxygen levels in the room drop below safe levels, providing peace of mind for families. Additionally, the built-in safety features, including a flame monitoring system, ensure a safe and reliable heating experience.

For those seeking convenience, the Desa models are compatible with remote controls and wall-mounted thermostats, allowing users to easily adjust heat settings without leaving the comfort of their couch. This versatility is particularly appealing in colder months when warmth is a priority.

Moreover, the fireplaces come with various media options, such as pebble beds or log sets, enhancing the visual appeal of the flames. The ambiance created by these fireplaces is not only about heat but about creating a cozy atmosphere that draws family and friends together.

In summary, the Desa DVF36TCR, DVF36TCL, and their respective models offer a unique blend of style, efficiency, and safety. With features aimed at enhancing user experience and optimizing home heating, these fireplaces stand out as leading options for those looking to add both warmth and elegance to their living spaces. Whether opting for gas or one of the electric versions, homeowners can trust in the quality and innovation present in the Desa DVF series.