Desa DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP, (V)DVF36TCLP(E), (V)DVF36TCRP(E)

Page 19

Installation

Continued

CAUTION: Due to high tem- peratures, make sure wires are not touching upper firebox.

Glass

Locating

Holes

Recommended

Blower Speed

Control

Location

Spring Latch

Figure 33 - Removing Louver

Electrical Hookup for optional blower accessory

Before blower accessory can be operated, the ap- pliance outlet box must be properly connected to a standard 120 VAC power source. This must be done when the appliance is originally installed. Refer to Wiring Diagrams on page 31.

An outlet box with two receptacles has been sup- plied for your convenience and is located on the lower right side of the appliance (see Figure 34). The variable speed controller is mounted on a magnetic base and may be positioned anywhere within an accessible distance behind the louvered opening (see Figure 33).

You may test the blower for operation by turning the control knob clockwise just until it clicks on which is the full on position. Adjust the fan speed to the lowest setting (this should be no more than 1/4 of a turn clockwise).

For Optional

Fan Kit

From Blower

Assembly

Figure 34 - Connecting Blower

Accessory to Power Supply

OPTIONAL Wireless hand-held REMOTE CONTROL Installation

Note: If using an optional wireless hand-held remote control, the wall switch is no longer operational.

NOTICE: Only use alkaline bat- teries (not included).

Installing HRC100 Model Remote Control (Millivolt Models Only)

1.Remove lower louver access panel in fire- place (see step 1 of Wall Switch Installation, page 18).

2.Disconnect wall switch wires from termi- nals marked TH and TPTH (see Figure 32, page 18).

3.Slide 9-volt battery into clip on back of remote receiver and connect battery terminals to bat- tery. Mount receiver onto bracket with clips provided (see Figure 35).

4.Connect white wire to control valve terminal TH and red wire to TPTH. Move remote select switch to REMOTE position.

5.Replace louvered access panel by following reverse of step 1 under Wall Switch Installa- tion, page 18.

6.Remove battery cover on back of hand-held remote (see Figure 36, page 20). Remove and discard sensor tag.

7.Attach terminal wires to 9-volt battery. Place battery into housing.

8.Replace battery cover onto hand-held remote.

9.Set selector switch on receiver to OFF posi- tion if you will be away from the unit for an extended period of time.

Plastic Mounting Clips

9-Volt Battery

Gas Receiver Clip

Valve Terminal

Wires

 

 

LOT

 

O N

 

16AI

 

OT

 

7

TH

L

 

I

 

 

 

P

 

 

 

FFO

L

 

TP

 

O

HI

E

A

 

TPTH

 

 

Red

White

FRONT

To Thermopile

 

Figure 35 - Installing Remote Receiver

(HRC100)

112108-01C

www.desatech.com

19

Image 19
Contents Right Side Corner Model Shown What to do if YOU Smell GASSafety Information Table of ContentsSafety Information High traffic areas Right Side Front View DimensionsPre-Installation Preparation TOP View Back ViewMantel Clearances ClearancesFraming Alternate Gas Supply Location Vent Termination Clearances General VentingMinimum Clearances for Termination Cap Installation Precautions Venting Installation InstructionsInstallation Planning Installing Vent System in a Chase Installation for horizontal terminationVent Pipe Connections Venting with Two 90 Elbows Horizontal VentingFlat Ceiling Installation Installation for vertical TerminationCathedral Ceiling Support Box Installation Cathedral Ceiling InstallationVenting with One 90 Elbow Vertical Rigid Venting Configuration Using One 90 ElbowDesa 5/8 Pipe & Vent Kits Number Description High altitude installationParts list for Desa venting kits and components Vertical VentingWall Switch Installation InstallationOptional Wireless hand-held Remote Control Installation Electrical Hookup for optional blower accessoryRemoved from ignition control circuit for GAS Line HOOK-UPNot Overtighten Gas Supply TestingON/OFF Installing Log SetDecorative Facing Pilot/Electrode Assembly AdjustmentBurner Removal Burner Flame AdjustmentCleaning and Replacing Glass Door Cleaning MaintenanceOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Operating FireplaceReplacement Parts Service HintsTechnical Service SpecificationsProblem Possible Cause Remedy TroubleshootingTroubleshooting See Wiring Diagrams Wiring DiagramsPilot Assembly Parts AccessoriesSkytech Remote Control KIT End Louver Kit Peninsula Only Grate End Glass Assembly Peninsula OnlyScreen Assembly Burner AssemblY Piezo Ignitor Blower kitHigh Voltage Cable Side Door Assembly 27200 CeramicIgnition Control LOG SET Refractory Pieces112108-01C Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

DVF36CR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP, DVF36TCR, DVF36TCL, DVF36TCR, DVF36TCL, DVF36TCRP, DVF36TCLP, (V)DVF36TCRP(E), (V)DVF36TCLP(E) specifications

The Desa DVF36TCR and DVF36TCL are part of a distinguished line of vent-free gas fireplaces designed to provide warmth and ambiance without the complexity of standard venting systems. These models, including DVF36TCRP, DVF36TCLP, and their electric variants (V)DVF36TCRP(E) and (V)DVF36TCLP(E), incorporate cutting-edge technology, ensuring efficient heating solutions that suit various home aesthetics and requirements.

One of the primary features of the DVF36TCR and DVF36TCL is their minimalist design, which allows for flexibility in installation. The option to choose between traditional and contemporary styles means that homeowners can select a model that complements their existing decor. The DVF36TCR boasts a classic design, while the DVF36TCL presents a more modern aesthetic, appealing to a broad range of personal styles.

Energy efficiency is another hallmark of these models. The Desa gas fireplaces utilize advanced burner technology that maximizes heat output while minimizing gas consumption. This efficiency not only translates to lower energy bills but also a reduced environmental impact, making these fireplaces a responsible choice for homeowners.

The DVF series also places a strong emphasis on safety. Each model is equipped with an oxygen depletion sensor (ODS) that automatically shuts off the gas supply if oxygen levels in the room drop below safe levels, providing peace of mind for families. Additionally, the built-in safety features, including a flame monitoring system, ensure a safe and reliable heating experience.

For those seeking convenience, the Desa models are compatible with remote controls and wall-mounted thermostats, allowing users to easily adjust heat settings without leaving the comfort of their couch. This versatility is particularly appealing in colder months when warmth is a priority.

Moreover, the fireplaces come with various media options, such as pebble beds or log sets, enhancing the visual appeal of the flames. The ambiance created by these fireplaces is not only about heat but about creating a cozy atmosphere that draws family and friends together.

In summary, the Desa DVF36TCR, DVF36TCL, and their respective models offer a unique blend of style, efficiency, and safety. With features aimed at enhancing user experience and optimizing home heating, these fireplaces stand out as leading options for those looking to add both warmth and elegance to their living spaces. Whether opting for gas or one of the electric versions, homeowners can trust in the quality and innovation present in the Desa DVF series.