Desa GCF26PR Mantel Clearances for BUILT-IN Installation, Optional Mantel Installation

Page 10

CGCF26PR

VENT-FREE PROPANE COMPACT FIREPLACE

INSTALLATION

Continued

MANTEL CLEARANCES FOR BUILT-IN INSTALLATION

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening. If your installation does not meet the mini- mum clearances in Figure 11, you must:

• raise the mantel to an acceptable height,

OR

• remove the mantel.

OPTIONAL MANTEL

INSTALLATION

Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installa- tion. Refer to instructions on page 4 for firebox assembly. Blower accessory should be installed if it is being used (see Accesso- ries, page 21).

1.Unscrew four brass screws that attach top louver to fireplace. Remove louvre from fireplace and set aside.

2.Place fireplace on wood base.

3.Place mantel around fireplace/base as- sembly.

4.Assemble brass trim kit. See Assem- bling Brass Trim.

5.Firmly snap brass trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 12).

6.Align brass trim kit for flush fit around opening.

7.Use two 3" wood screws provided and attach fireplace base to wooden base (see Figure 12).

8.Remove brass trim kit and mantel. Be careful not to damage wall or mantel.

9.Place wood base next to wall at instal- lation location.

10.Attach wood base to floor with two 1 3/4" black screws provided (see Figure 13). If the floor is concrete use anchor method (see Attaching Wood Base to Solid Floor, page 11).

11.Install gas line. See Connecting To Gas Supply, page 11.

12.Check for leaks. See Checking Gas Connections, page 13.

13.Place mantel around fireplace. Be care- ful not to damage wall or mantel.

14.Place brass trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the brass trim over the shoulder screws on fireplace (see Figure 12).

15.Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the man- tel. The openings are located at top be- hind the area for the brass louvers (see Figure 13).

16.Reinstall top brass louvers.

Note: All vertical

 

Mantel Shelf

10"

 

 

 

 

measurements

 

 

 

 

are from top of

8"

 

 

 

 

 

 

 

 

fireplace

6"

 

 

 

 

opening to

 

 

 

 

2 1/2"

 

 

 

 

bottom of

 

 

 

 

mantel shelf.

 

 

 

 

 

Minimum Non-

 

 

 

 

 

Combustible

 

 

 

 

 

Material

13"

16"

19"

21"

 

 

 

 

 

 

 

 

 

Figure 11 - Minimum Mantel Clearances for Built-In Installation

Hole for 3" wood

screw for attaching

Shoulder Screws fireplace to wooden base

Hole for 3" wood

Assembled

screw for attaching

Brass Trim

fireplace to mantel

 

Figure 12 - Attaching Brass Trim to Fireplace

1 3/4" Screw

Wood Base

Figure 13 - Attaching Wood Base to Floor

Assembling Brass Trim (Brass trim shipped with mantel)

1.Remove packaging from three remain- ing pieces of brass trim.

2.Locate two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 14.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 14).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 14).

6.While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other corner.

8.Set Brass Assembly aside for later in- stallation.

Slot

Set ScrewsTop

Brass

Trim

Shim

Mitered Edge

 

Adjusting

Plate

Side

SlotBrass

Trim

Figure 14 - Assembling Brass Trim

10

104324

Image 10
Contents VENT-FREE PROPANE/LP GAS Compact Fireplace What to do if YOU Smell GASSafety Information VENT-FREE Propane Compact FireplaceLocal Codes Product FeaturesProduct Identification UnpackingAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation DepthAssembling Brass Trim Brass trim shipped with mantel Mantel Clearances for BUILT-IN InstallationOptional Mantel Installation Raise the mantel to an acceptable height Remove the mantelAttaching Wood Base to Solid Floor Connecting to GAS SupplyFor attaching base to solid floors concrete or masonry Connecting Fireplace to GAS Supply Installation Items NeededInstalling 9-VOLT Battery for Wireless Remote Control Checking GAS ConnectionsOperating Fireplace For Your Safety Read Before LightingLighting Instructions Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Hand Held Remote OperationReplacement Parts Cleaning and MaintenanceInspecting Burners Troubleshooting Lation requirements Pane gas companyGas odor even when control knob is in OFF position TopTechnical Service SpecificationsService Hints Wiring DiagramFinished Oak Veneer- GMC43F Unfinished Oak Veneer AccessoriesValve GA5010 Manual shutoff valve with 1/8 NPT tapIllustrated Parts Breakdown CGCF26PRParts List KEY CGCF26PR Description QTYWarranty Information