Shutting Off Fireplace

1.Turn control knob clockwise to the OFF position.

2.Set remote selector switch in the OFF position to prevent draining battery.

Shutting Off Burner Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise to the PILOT position.

2.Use remote control manual OFF button.

3.Set remote selector switch in the OFF position.

THERMOSTAT

CONTROL

OPERATION

The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automati- cally to maintain the comfort level you

HAND HELD REMOTE

OPERATION

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 14.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the remote selector switch to the REMOTE position. The burners will come on. You can now turn the burners on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the re- mote selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.

2.Select the MANUAL or AUTO but- ton on the hand-held remote control unit.

In MANUAL mode, turn burners on or off by pressing the ON or OFF buttons on the hand-held re- mote control unit.

In AUTO mode, the room tempera- ture is controlled by the thermo- stat in the hand-held remote con- trol unit. To increase the room tem-

perature, press the top arrow of the TEMP button. To lower room the temperature, press the bottom ar- row to the TEMP button. At higher settings the heater will run more. IMPORTANT: The hand-held re- mote control unit must be near the heater. Do not keep the hand-held remote control unit too close the heater. The thermostat on the hand-held remote control unit will heat up too quickly and turn the heater off.

3.Use the STATUS button on the hand- held remote control unit to see the operation mode being used and the temperature setting selected. A red light will come on beside the opera- tion mode being used when the sta- tus button is pressed.

4.To turn the burners off when oper- ating in the MANUAL mode, press the OFF button. If operating in the auto mode, press the manual button, then press the OFF button The pilot will remain lit.

IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position or set re- mote selector switch to OFF position.

Control Knob in

Flame Adjustment Knob

On Position

 

select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 6 under Light-

REMOTE

 

 

 

OL

N

 

 

 

OFF

 

 

 

O

 

F O

 

ON

T

 

 

 

O

 

F

 

 

L

 

HI

 

 

IP

 

Remote Selector Switch in Remote Position

Figure 26 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

 

ing Instructions, page 14.

2.

Depress control knob and light pilot

 

with match.

3.

Keep control knob pressed in for 30

 

seconds after lighting pilot. After 30

 

seconds, release control knob. Now

 

follow step 9, on page 14.

Shows Temperature Setting

Allows Burners to be Turned On and Off with the Hand-Held Remote Unit.

The log heater will automatically cycle between pilot and the heat setting that has been selected.

HI

TEMP

MAN LO ON

AUTO OFF

STATUS

Increases Room Temperature

Decreases Room Temperature

Turns Burners On and Off

Shows Current Operation Mode

Figure 27 - Thermostat Hand-Held Remote Control Unit Selections

104324

15

Image 15
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS Compact FireplaceVENT-FREE Propane Compact Fireplace Safety InformationUnpacking Product FeaturesProduct Identification Local CodesAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Fireplace InstallationInstallation Items Check GAS TypeDepth BUILT-IN Fireplace InstallationRaise the mantel to an acceptable height Remove the mantel Mantel Clearances for BUILT-IN InstallationOptional Mantel Installation Assembling Brass Trim Brass trim shipped with mantelConnecting to GAS Supply Attaching Wood Base to Solid FloorFor attaching base to solid floors concrete or masonry Installation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Installing 9-VOLT Battery for Wireless Remote ControlFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Hand Held Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationCleaning and Maintenance Replacement PartsInspecting Burners Troubleshooting Pane gas company Lation requirementsTop Gas odor even when control knob is in OFF positionWiring Diagram SpecificationsService Hints Technical ServiceManual shutoff valve with 1/8 NPT tap AccessoriesValve GA5010 Finished Oak Veneer- GMC43F Unfinished Oak VeneerCGCF26PR Illustrated Parts BreakdownKEY CGCF26PR Description QTY Parts ListWarranty Information