CGCF26PR

VENT-FREE PROPANE COMPACT FIREPLACE

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 16) or replace burner orifice

 

2.

Inlet gas pressure is too low

2.

Contact local propane gas company

 

3.

Burner orifice diameter is too small

3.

Replace burner orifice

 

4.

Thermopile leads disconnected or im-

4.

Reconnect leads (see Wiring Diagram,

 

 

properly connected

 

page 20)

 

5.

Burners will not come on in remote po-

5.

Replace battery in transmitter and re-

 

 

sition

 

ceiver

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane gas company

 

2.

Burner orifice clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 16) or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 16) or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

Maintenance, page 16)

 

2.

Gas regulator defective

2.

Replace gas control

 

3.

Residues from manufacturing processes

3.

Problem will stop after a few hours of

 

 

and logs curing

 

operation

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

lation requirements (page 5)

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

pane gas company

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

ances (see pages 8 through 10)

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 16) or replace burner orifice

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

18

104324

Image 18
Contents VENT-FREE PROPANE/LP GAS Compact Fireplace What to do if YOU Smell GASSafety Information VENT-FREE Propane Compact FireplaceLocal Codes Product FeaturesProduct Identification UnpackingAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation DepthAssembling Brass Trim Brass trim shipped with mantel Mantel Clearances for BUILT-IN InstallationOptional Mantel Installation Raise the mantel to an acceptable height Remove the mantelConnecting to GAS Supply Attaching Wood Base to Solid FloorFor attaching base to solid floors concrete or masonry Connecting Fireplace to GAS Supply Installation Items NeededInstalling 9-VOLT Battery for Wireless Remote Control Checking GAS ConnectionsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Hand Held Remote OperationCleaning and Maintenance Replacement PartsInspecting Burners Troubleshooting Lation requirements Pane gas companyGas odor even when control knob is in OFF position TopTechnical Service SpecificationsService Hints Wiring DiagramFinished Oak Veneer- GMC43F Unfinished Oak Veneer AccessoriesValve GA5010 Manual shutoff valve with 1/8 NPT tapIllustrated Parts Breakdown CGCF26PRParts List KEY CGCF26PR Description QTYWarranty Information