Desa GCF26PR Checking GAS Connections, Installing 9-VOLT Battery for Wireless Remote Control

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure external regulator has been installed be- tween propane/LP supply and fire- place. See guidelines under Con- necting to Gas Supply, page 11.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Figure 20).

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to manual shutoff valve (see Figure 21). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1.Open manual shutoff valve (see Figure 20).

2.Open propane/LP supply tank valve.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from manual shutoff valve to thermostat gas valve (see Fig- ure 19). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fire- place, pages 14 and 15). Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 15).

8.Replace front panel.

Open

Manual

Shutoff

Valve

Closed

Figure 20 - Manual Shutoff Valve

Propane/LP

Supply

Tank Manual

Shutoff

Valve

Figure 21 - Checking Gas Joints Shown with Optional Mantel

INSTALLING 9-VOLT BATTERY FOR WIRELESS REMOTE CONTROL

Two 9-volt batteries (not included) are required to operate this heater with the wireless hand held remote control set. One battery must be installed in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Battery in Receiver

1.Locate back of receiver located at the bottom, left side of the heater base.

2.Locate the battery clip mounted on the back of the receiver.

3.Slide a 9-volt battery through the clip.

4.Attach the terminal wires to the battery.

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 22 - Attaching Battery to Receiver

Installing 9-Volt Battery in Hand- Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to the battery. Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery Cover Remote Control Unit

Terminal

Wires

Battery Housing

9-Volt Battery

Figure 23 - Installing Battery in Hand- Held Remote Control Unit

104324

13

Image 13
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS Compact FireplaceVENT-FREE Propane Compact Fireplace Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingInstalling Log AssemblyAssembling Fireplace Assembling HoodProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating FireplaceDepth BUILT-IN Fireplace InstallationOptional Mantel Installation Mantel Clearances for BUILT-IN InstallationAssembling Brass Trim Brass trim shipped with mantel Raise the mantel to an acceptable height Remove the mantelAttaching Wood Base to Solid Floor Connecting to GAS SupplyFor attaching base to solid floors concrete or masonry Installation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Installing 9-VOLT Battery for Wireless Remote ControlOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Hand Held Remote OperationReplacement Parts Cleaning and MaintenanceInspecting Burners Troubleshooting Pane gas company Lation requirementsTop Gas odor even when control knob is in OFF positionService Hints SpecificationsTechnical Service Wiring DiagramValve GA5010 AccessoriesFinished Oak Veneer- GMC43F Unfinished Oak Veneer Manual shutoff valve with 1/8 NPT tapCGCF26PR Illustrated Parts BreakdownKEY CGCF26PR Description QTY Parts ListWarranty Information