Desa (V)VC36P Series Installing lava rock and glowing embers, Cleaning Glass Door

Page 26

Fireplace

Installation

Continued

4.Remount the new frame at the hinge with five new screws before closing door. This will ensure seating of the gasket.

5.Close glass door frame. Lock latches by placing the bar under the tab on door and pushing down and back on latch (see Figure 42, page 25).

6.Replace screen/rod assembly by reversing step 1.

7.Replace louvers by reversing procedure under Removing Louver Panels, page 25.

Cleaning Glass Door

See Cleaning and Maintenance on page 31.

Installing lava rock and glowing embers

It is very important to keep logs exactly as installed. Do not modify logs. Only use log set designed for this fireplace. Logs under log/grate assembly are attached to burner. Do not attempt to move these logs as this will damage logs.

WARNING: Logs are unitized and attached to the grate. Do not handle log/grate assembly by logs. Always pick up by grate.

Open louvers, remove screen, unlock door latches and open glass door. See Removing Glass Door, steps 1 and 2, page 25.

1.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and spar- ingly directly onto the exposed front section of the burner (see Figure 43). This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided.

2.Pour lava rock onto plenum but not onto flat burner. It is not necessary to use all of the lava rock provided.

NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner will cause performance problems.

3.Close glass door, lock door latches, replace screen and close louvers (see Removing Glass Door, steps 5 through 7).

WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken.

Plenum

Embers

Figure 43 - Placing Ember Material on

Burner

Installing Brick liner Models BL36DA(SA) and BL36DHA(SA)

WARNING: If fireplace has been running, turn off unit. Let cool before installing brick liner.

You may purchase brick liner from your local retailer or see Accessories, page 42.

CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Excessive force will break brick panels.

1.Remove top and bottom louvers to allow ac- cess to door latches.

2.Unlock door latches and open glass door. See Removing Glass Door, steps 1 and 2, page 25.

3.Carefully remove lava rock and ember material. Remove log/grate assembly by unscrewing grate from plenum. The two logs under the grate are at- tached to burner. DO NOT attempt to remove.

4.Remove screws that attach plenum to burner to remove plenum.

5.Remove three screws from deflector shield on the inside top of firebox. Set shield and screws aside.

26

www.desatech.com

116200-01H

Image 26
Contents What to do if YOU Smell GAS Patent PendingTable of Contents Safety InformationSafety information High traffic areas Product IdentificationLocal Codes Location and space requirements Product FeaturesPre-Installation Preparation This fireplace does not require electricity to operateClearances Framing and finishingClearances for Combustible Mantels Location of Termination Cap Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Round TerminationCorner Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionModel BK Installation Fireplace InstallationInstalling optional blower accessories Plug in blower power cordModel BKT Installation Blower Model BKTInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Connecting Fireplace to GAS Supply Propane/LP Supply TankExternal Regulator Vent Pointing DownClose equipment shutoff valve see Figure Checking GAS ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Installing Remote Receiver Installing optional wall Mount Switch gwmS2Pressure Testing Fireplace Gas Connections Turn off fireplace see To Turn Off Gas to Ap- pliance,Removing Glass Door Removing/Replacing Glass DoorRemoving Louver Panels Cleaning Glass Door Installing lava rock and glowing embersInstalling Brick liner Models BL36DASA and BL36DHASA Lighting Instructions For your safety Read before lightingOperating Fireplace Close top and bottom louversOptional Hand-Held Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationOn/Off Series Model HRC100 Thermostat Series Model HRC200Key Pad Lock Feature Operating optional blower accessoryPilot assembly Inspecting BurnersGlass Door Cleaning MaintenanceBurner Flame Pattern Venting system Pilot and burnersLogs Troubleshooting Observed Problem Possible Cause RemedyAfter pilot lights, keep gas Problem could be caused byBurner orifice clogged Clean burner see Cleaning Is lit Long enough Control knob pressedTery power is low When burner is lit HI position when burner isOr shut off Service person Remote does not function Cold Minute Air in gas line Operate burner until air isStatement above Technical Service Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown Parts List 19 18 116200-01H Burner Pan Assembly Accessories Wall mounted on/off switch gwmS2 Not Shown Wall mounted thermostat control kit gwmt1 Not ShownLimited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty