Hold the control button on the hand-held remote until burner turns on. Hold the con- trol button again until burner turns off (see Figure 47).

To Lock press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

To Unlock press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Indicator

LightControl

Button

Figure 47 - On/Off Hand-Held Remote

Control Unit HRC100

Thermostat Series Model

HRC200

The hand-held remote can be operated using either the manual mode (MANU) or thermo- static mode (AUTO) (see Figure 48). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1. Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2. Press the MANU button to turn on the fireplace.

3. Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1. Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2. Press AUTO button to select this mode.

3.Set the desired room temperature by pressing the TEMP + or - buttons.

4.Press the POWER and LOCK buttons together to turn off the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Digital Display Shows

Temperature and Settings

Locks

 

 

 

Turns

System to

 

 

 

 

 

 

Hand-Held

Prevent

 

 

 

 

AUTO

Remote On

Accidental

ROOM

 

SET

TEMP

 

TEMP

or Off and

Ignition

 

 

 

Allows You

 

 

 

 

 

LOCK

TEMP

POWER

to Choose

 

 

Turns

 

 

 

the Manual

Burners

MANU

ºC/ºF

AUTO

Setting

On or Off

 

 

 

 

 

 

Selects

 

 

 

 

 

 

 

 

AUTO

Increases or

 

 

 

Mode

 

 

 

 

Decreases

 

 

 

 

Room

 

 

 

°C/°F Mode

Temperature in

 

 

 

 

 

 

Button

AUTO Mode

 

 

 

 

 

 

 

Figure 48 - Thermostat Hand-Held

Remote Control Unit HRC200

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1. If the average room temperature exceeds

82 degrees Fahrenheit (28 degrees Centi- grade), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2. The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

116200-01H

www.desatech.com

29

Image 29
Contents Patent Pending What to do if YOU Smell GASSafety Information Table of ContentsSafety information High traffic areas Product IdentificationLocal Codes Pre-Installation Preparation Product FeaturesLocation and space requirements This fireplace does not require electricity to operateFraming and finishing ClearancesClearances for Combustible Mantels Balcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Corner InstallationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsInstalling optional blower accessories Fireplace InstallationModel BK Installation Plug in blower power cordBlower Model BKT Model BKT InstallationInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Propane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyClose equipment shutoff valve see Figure Checking GAS ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas Connections Installing optional wall Mount Switch gwmS2Installing Remote Receiver Turn off fireplace see To Turn Off Gas to Ap- pliance,Removing Glass Door Removing/Replacing Glass DoorRemoving Louver Panels Cleaning Glass Door Installing lava rock and glowing embersInstalling Brick liner Models BL36DASA and BL36DHASA Operating Fireplace For your safety Read before lightingLighting Instructions Close top and bottom louversTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 On/Off Series Model HRC100Pilot assembly Operating optional blower accessoryKey Pad Lock Feature Inspecting BurnersGlass Door Cleaning MaintenanceBurner Flame Pattern Venting system Pilot and burnersLogs Observed Problem Possible Cause Remedy TroubleshootingBurner orifice clogged Clean burner see Cleaning Is lit Problem could be caused byAfter pilot lights, keep gas Long enough Control knob pressedOr shut off Service person Remote does not function When burner is lit HI position when burner isTery power is low Cold Minute Air in gas line Operate burner until air isStatement above Service Hints Replacement PartsTechnical Service SpecificationsIllustrated Parts Breakdown Parts List 19 18 116200-01H Burner Pan Assembly Accessories Wall mounted thermostat control kit gwmt1 Not Shown Wall mounted on/off switch gwmS2 Not ShownLimited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty