Desa VC36N, C GCDV36NR, VC36P, C GCDV36PR, (V)VC36P Series installation manual Parts List

Page 39

PARTS LIST

Models Vc36N, VVc36N, Vc36P, VVc36P, cgcdv36nr and cgcdv36pr Series

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

1

**

Firebox Assembly

2

**

Face Weldment

3

108010-01

Door Assembly

 

108010-02

Door Assembly (V Models Only)

4

108011-01

Top Louver Assembly

5

108011-02

Bottom Louver Assembly

6

**

Fireplace Top

7

**

Fireplace Top Insulation

8

**

Fireplace Surround

9

109082-01

Heat Shield

10

116215-01

Log Set with Grate Assembly

11

116338-01

Right Burner Log

12

116339-01

Left Burner Log

13

See Below

Left Refractory Brick Panel

14

See Below

Rear Refractory Brick Panel

15

See Below

Right Refractory Brick Panel

16

108719-01

Screen Rod

17

12105

Screen

18

11418

Push-On Nut

19

14123

Strain Relief

20

21171

Gas Knock-Out Cover

21

24353

Handy Box Assembly

22

24460

Gas Conduit Assembly

23

116210-01

Burner Assembly (Natural Gas) (See page 40)

 

116210-02

Burner Assembly (Propane/LP Gas) (See page 40)

 

116211-05

Burner Assembly for High Altitude Models (See page 40)

24

116374-01

Plenum

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

 

 

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

1

2

1

1

1

1

1

1

25487

Lava Rock/Bag Assy

27253

Notice Label

55240

Vent Label

116388-01

Grate Finial

** Part not available for field replacement.

REFRACTORY BRICK PANELS

CGCDV36NR

CGCDV36PR

VC36NB(-HA) VVC36NB(-HA) V36NH VVC36NH

VC36PB VVC36PB V36PH VVC36PH DESCRIPTION

1

1

1

2

QTY

110989-02

110989-01

110991-02

110991-01

110990-02

110990-01

111215-02

111215-01

Left Refractory Brick Panel

111217-02

111217-01

Rear Refractory Brick Panel

111216-02

111216-01

Right Refractory Brick Panel

1

1

1

116200-01H

www.desatech.com

39

Image 39
Contents Patent Pending What to do if YOU Smell GASSafety Information Table of ContentsSafety information Product Identification Local CodesHigh traffic areas This fireplace does not require electricity to operate Product FeaturesPre-Installation Preparation Location and space requirementsFraming and finishing ClearancesClearances for Combustible Mantels Balcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Corner InstallationHorizontal System Installation Using TWO 90 Elbows Installation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsPlug in blower power cord Fireplace InstallationInstalling optional blower accessories Model BK InstallationBlower Model BKT Model BKT InstallationInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Propane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaClose equipment shutoff valve see Figure Turn off fireplace see To Turn Off Gas to Ap- pliance, Installing optional wall Mount Switch gwmS2Pressure Testing Fireplace Gas Connections Installing Remote ReceiverRemoving/Replacing Glass Door Removing Louver PanelsRemoving Glass Door Installing lava rock and glowing embers Installing Brick liner Models BL36DASA and BL36DHASACleaning Glass Door Close top and bottom louvers For your safety Read before lightingOperating Fireplace Lighting InstructionsRemote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldThermostat Series Model HRC200 On/Off Series Model HRC100Inspecting Burners Operating optional blower accessoryPilot assembly Key Pad Lock FeatureCleaning Maintenance Burner Flame PatternGlass Door Pilot and burners LogsVenting system Observed Problem Possible Cause Remedy TroubleshootingLong enough Control knob pressed Problem could be caused byBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasCold Minute Air in gas line Operate burner until air is When burner is lit HI position when burner isOr shut off Service person Remote does not function Tery power is lowStatement above Specifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Parts List 19 18 116200-01H Burner Pan Assembly Accessories Wall mounted thermostat control kit gwmt1 Not Shown Wall mounted on/off switch gwmS2 Not ShownWarranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace