Desa VC36N, C GCDV36NR, VC36P, C GCDV36PR, (V)VC36P Series installation manual Burner Pan Assembly

Page 41

PARTS LIST

Burner assembly for models Vc36N, VVc36N, Vc36P, VVc36P, cgcdv36nr and cgcdv36pr

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual.

KEY

PART

 

QTY.

NO.

NUMBER

DESCRIPTION

1

**

Burner Pan Assembly

2

**

Base Grate

3

**

Firebox Base Bottom

4

26808

Valve Bracket

5

11107

Screw, #10-32 x 1/4 Zinc

6

**

Firebox Bottom

7

11102

Screw, #8-32 x 3/8 Zinc

8 116344-01 Tubing Assembly

9 111288-02 Flex Gas Line

10

108084-02

Pilot Assembly (Natural Gas)

 

108084-03

Pilot Assembly (Propane/LP Gas)

 

108084-05

Pilot Assembly (-HA Models)

11

14389

 

Natural Gas Valve

 

14390

 

Propane/LP Gas Valve

 

117370-01

Natural Gas High Altitude Valve

12

11165

 

Screw, #10 x 5/8 Zinc

13

111913-01

Burner Base Gasket

14

14396

 

Brass Fitting

15

116345-01

Pilot Bracket

16

26827

 

Switch Bracket

17

11226

 

Flat Washer 7/8" ID x 2" OD

18

11214

 

Bulkhead Fitting with Washer

19

14296

 

Elbow 3/8"

20

24873

 

Burner Orifice #36 (Natural Gas)

 

25238

 

Burner Orifice #52 (Propane/LP Gas)

21

14492

 

Piezo Ignitor

22

14511

 

Piezo Bracket

 

 

PARTS AVAILABLE - NOT SHOWN

 

 

1

1

1

1

4

1

2

1

1

1

1

1

1

1

1

23

1

2

1

1

2

2

1

1

1

1

1

108085-03 Pilot Assembly (-HA Models - NG)

**Not a field replaceable part.

1

116200-01H

www.desatech.com

41

Image 41
Contents Patent Pending What to do if YOU Smell GASSafety Information Table of ContentsSafety information High traffic areas Product IdentificationLocal Codes Pre-Installation Preparation Product FeaturesLocation and space requirements This fireplace does not require electricity to operateFraming and finishing ClearancesClearances for Combustible Mantels Balcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Corner InstallationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsInstalling optional blower accessories Fireplace InstallationModel BK Installation Plug in blower power cordBlower Model BKT Model BKT InstallationInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Propane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyClose equipment shutoff valve see Figure Checking GAS ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas Connections Installing optional wall Mount Switch gwmS2Installing Remote Receiver Turn off fireplace see To Turn Off Gas to Ap- pliance,Removing Glass Door Removing/Replacing Glass DoorRemoving Louver Panels Cleaning Glass Door Installing lava rock and glowing embersInstalling Brick liner Models BL36DASA and BL36DHASA Operating Fireplace For your safety Read before lightingLighting Instructions Close top and bottom louversTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 On/Off Series Model HRC100Pilot assembly Operating optional blower accessoryKey Pad Lock Feature Inspecting BurnersGlass Door Cleaning MaintenanceBurner Flame Pattern Venting system Pilot and burnersLogs Observed Problem Possible Cause Remedy TroubleshootingBurner orifice clogged Clean burner see Cleaning Is lit Problem could be caused byAfter pilot lights, keep gas Long enough Control knob pressedOr shut off Service person Remote does not function When burner is lit HI position when burner isTery power is low Cold Minute Air in gas line Operate burner until air isStatement above Service Hints Replacement PartsTechnical Service SpecificationsIllustrated Parts Breakdown Parts List 19 18 116200-01H Burner Pan Assembly Accessories Wall mounted thermostat control kit gwmt1 Not Shown Wall mounted on/off switch gwmS2 Not ShownLimited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty