Desa VV36ENC1 SERIES Installing logs, lava rock and glowing embers, Wall Switch Installation

Page 20

Fireplace Installation

Continued

Installing logs, lava rock and glowing embers

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs sup- plied with fireplace.

Open louvers, remove screen, unlock door latches, and open glass door. See steps 1 and 2 of Removing/Replacing Glass Door, page 18. Install logs according to instructions for fireplace model numbers.

1.Place log #1 (base log) onto pin on left side of burner as shown in Figure 40.

2.Rest left side of log #2 (front log) onto top of log #1. Place right side of log onto second pin located on right side of grate (see Figure 42).

3.Place logs #3 (rear log) onto pin on rear of grate as shown in Figure 41.

4.Place log #4 (crossover log) onto pins from both logs #2 and #3 as shown in Figure 43.

5.Place log #5 (top log) onto right pin of front log (#2) and smooth surface of crossover log (#4) as shown in Figure 44. Make sure it is seated properly.

6.Place log #6 (left log) onto left pin of front log (#2) and smooth surface of rear log (#3) as shown in Figure 45. Make sure it is seated properly.

7.Place log #7 onto right pin of top log (#5) as shown in Figure 45. Make sure it is seated properly.

8.Place lava rock along sides and front of firebox bottom in areas that are visible only. It is not necessary to use all of the lava rock provided.

1

2

 

Figure 40 - Installing Log

Figure 41 - Installing Log

No. 1

No. 2

3

4

 

Figure 42 - Installing Log

Figure 43 - Installing Log

No. 3

No. 4

NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner will cause performance problems.

9.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto exposed section of front burner and along space between burner and grate prongs (see Figure 46). This will create a glowing ember appearance as the flame touches ember material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided.

10.Close glass door, lock door latches, replace screen and close louvers (see Removing/Replacing Glass Door, steps 5 through 7 on page 19.

WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken.

5

6

7

 

 

 

Figure 44 - Installing Log

Figure 45 - Installing Logs

No. 5

No. 6 and No. 7

Ember Material

Figure 46 - Placing Ember Material on Burner

WALL SWITCH INSTALLATION

The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies the electricity to the fireplace. See Wiring Diagram on page 21.

optional Remote control

INSTALLATION (model WRC)

Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace op- eration.

1.Open lower louver panel of firebox.

2.The WRC model receiver does not require a battery. The receiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 47, page 21).

20

www.desatech.com

111253-01F

Image 20
Contents For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationLocal Codes Product FeaturesProduct Identification Clearances Pre-Installation PreparationLocation and space requirements Framing Clearances for Installation Against an Exterior Wall Framing and finishingLocation of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationVent Pipe Connections Vent pipe before connecting horizontal run to vent cap see Horizontal Termination Configurations Ground Floor InstallationSnorkel Termination Installation Venting with Two 90 ElbowsFlat Ceiling Installation Offset with Wall Strap and 45 ElbowsVertical Termination Configurations Vertical VentingFireplace Installation High Altitude InstallationParts lists for venting kits and components Installing optional blower accessoriesModel BKT Installation Attaching Speed Control to FireboxInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Connecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Removing/Replacing Glass DoorRemoving Louver Panels Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Optional Brick liner Models BL42DASA, BL42DHASA Cleaning Glass DoorUnplug fireplace. Let cool before installing brick liner Removing Glass DoorOptional Remote control Installation model WRC Installing logs, lava rock and glowing embersWall Switch Installation Wiring Diagram Pilot Burner Pilot Gas LineOptional Remote Operation Operating FireplaceTo Turn OFF GAS Cleaning Maintenance Pilot assemblyInspecting Burners Burner Flame PatternVenting system Pilot and burnersLogs Troubleshooting To clean pilot. This can damage pilot unitGas leak. See Warning statement at Top aboveReplacement Parts Service HintsTechnical Service SpecificationsIllustrated Parts Breakdown Parts List Parts Available not ShownIllustrated parts breakdown Parts List Accessories 111253-01F Warranty Information Keep this Warrant