Desa EFS33NR, EFS33NRA, EFS33PR, EFS33PRA VSGF33NR, VSGF33NRA, VSGF33PR, VSGF33PRA

Page 15

INSTALLATION

Installing Logs (Cont.)

15

INSTALLATION

Continued

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is in place before running fireplace.

Notches

Screws for

Mounting Screen

Figure 28 - Installing Fireplace Screen

INSTALLING LOGS (MODELS EFS33NRA, EFS33PRA, VSGF33NRA, AND VSGF33PRA)

WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important safety and warranty information.

It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place front log on top of the grate. Make sure the notches in the bottom of the log fit over the grate prongs (see Figure 29). Push back of logs flush with metal grate bars.

2.Rest middle log behind metal posts on grate assembly. Make sure the grooves in the bottom of the log fit over the grate. Bring the log forward next to the metal posts (see Figure 30).

3.Slide the grooves in the back of the rear log against the rear grate prongs. Make sure the log fits securely over the prongs (see Figure 31). Make sure log is completely vertical and not leaning in toward burner where the flame will touch the log.

4.Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 28).

 

Front Log

Notch

Metal

 

 

Grate

Grate

Bars

 

Prongs

 

Figure 29 - Installing Front Log

 

 

Middle Log

Groove

Groove

 

 

Grate

Metal Post

 

Figure 30 - Installing Middle Log

 

Groove in

Rear Log

Back of Log

 

Grate Prong

Groove in

 

Back of Log

 

Grate Prong

Figure 31 - Installing Rear Log

For morevisit www..com

107172-01G

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Log Base Assembly VSGF33NRA ShownAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeAssembling and Attaching Optional Brass Trim Installation ClearancesConventional Fireplace Installation Included with Mantel AccessoryPlacing Hearth Base Accessory Against Wall Mantel Clearances for Built-In Installation BUILT-IN Fireplace InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationGas Connection Connecting Equipment Shutoff Valve to Heater ControlPressure Testing gas Supply Piping system Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Place front log on top of the grate. Make sure the notches Installing Fireplace Screen For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Main Burner Inspecting BurnersPilot Flame Pattern Optional Blower OperationCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, For Visit Com Service Hints Wiring DiagramSpecifications Replacement PartsIllustrated Parts Breakdown Not a field replaceable part Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Laminate Trim for Hearth or Mantel Cabinet Mantel and Full Hearth BaseCorner Hearth Base Hardwood Hearth BaseNot Shown Receiver and HAND-HELD Remote Control KIT GHRC/CGHRC SeriesWALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2Owners Registration Form Tape 107172-01G Warranty Information