Desa EFS33NR, EFS33NRA, EFS33PR, EFS33PRA VSGF33NR, VSGF33NRA, VSGF33PR, VSGF33PRA Wiring Diagram

Page 23

WIRING DIAGRAM

Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown.

A

 

UT

O

OF

ON

F

 

Thermopile

SPECIFICATIONS

MODELS EFS33NR, EFS33NRA, VSGF33NR, and VSGF33NRA

Btu (Variable)

20,000/33,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

Minimum*

5"

Shipping Weight

122 lbs.

* For input adjustment

 

MODELS EFS33PR, EFS33PRA, VSGF33PR, and VSGF33PRA

Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

7.9" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

13"

Minimum*

11"

Shipping Weight

122 lbs.

* For input adjustment

 

WIRING DIAGRAM

SPECIFICATIONS 23

REPLACEMENT PARTS

SERVICE HINTS

TECHNICAL SERVICE

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040.

When calling DESA Heating Products, have ready

your name and address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low for propane/LP unit

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical services web site at www.desatech.com.

For morevisit www..com

107172-01G

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Log Base Assembly VSGF33NRA ShownAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Electrical Hookup InstallationInstalling Hood Check GAS TypeAssembling and Attaching Optional Brass Trim Installation ClearancesConventional Fireplace Installation Included with Mantel AccessoryPlacing Hearth Base Accessory Against Wall Mantel Clearances for Built-In Installation BUILT-IN Fireplace InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationGas Connection Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections Place front log on top of the grate. Make sure the notches Installing Fireplace Screen Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Main Burner Inspecting BurnersPilot Flame Pattern Optional Blower OperationLogs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingMaintenance, For Visit Com Service Hints Wiring DiagramSpecifications Replacement PartsIllustrated Parts Breakdown Not a field replaceable part Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Laminate Trim for Hearth or Mantel Cabinet Mantel and Full Hearth BaseCorner Hearth Base Hardwood Hearth BaseNot Shown Receiver and HAND-HELD Remote Control KIT GHRC/CGHRC SeriesWALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2Owners Registration Form Tape 107172-01G Warranty Information