Desa VSGF33PRA Assembling and Attaching Optional Brass Trim, Installation Clearances

Page 8

8

INSTALLATION

Assembling and Attaching Optional Brass Trim

Installation Clearances

Conventional Fireplace Installation

INSTALLATION

Continued

ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIM

(Included with Mantel Accessory)

IMPORTANT: If you are recessing the firebox in a wall, do not attach brass trim at this time. See Built-In Fireplace Installation, pages 10 and 11.

Note: The instructions below show assembling and attaching brass trim to fireplace.

1.Remove packaging from three pieces of brass trim.

2.Locate four brass screws, two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 6.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 6).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 6).

6.While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other side.

8.Tighten trim hanging screws (#10 x 6.25 shoulder) into holes in cabinets. Place the assembled trim onto fireplace cabinet. Align hanging notches on trim with hanging screws on side of fireplace (see Figure 7). Push trim firmly into place, sliding hanging notches over hanging screws.

Side Brass

Adjusting

Set Screws

Top

Trim

Plate

Brass

 

 

Trim

Shim

Slot

 

Slot Mitered Edge

 

Figure 6 - Assembling Brass Trim

Trim

 

 

Hanging

 

Screws

Hanging

Notches

on Trim

Assembled

Brass Trim

Figure 7 - Attaching Brass Trim to Fireplace (VSGF33NRA Shown)

INSTALLATION CLEARANCES

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceil- ing, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 8.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 8).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

 

Right Sides

and Rear

0"

16"

0"

 

Example

 

*

*Minimum 16 inches from Side Wall

Figure 8 - Minimum Clearance for Combustible to Wall

CONVENTIONAL FIREPLACE INSTALLATION

Conventional installation of this fireplace involves installing fire- place along with the corner, face, or cabinet mantel with hearth base accessories against a wall in your home. Follow the instructions in this section to install the fireplace in this manner.

Note: The instructions in this section show installation using the cabinet mantel and the G3333F/G3334U/G3004W/G3335F/ G3007U series hearth base accessories. The hearth base accessory shown is optional for this installation. You can install fireplace and

Forvisit..com

107172-01G

Image 8
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationLog Base Assembly VSGF33NRA Shown Product IdentificationProduct Features Local CodesUnpacking AIR for Combustion and VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Installing HoodCheck GAS Type Electrical HookupInstallation Clearances Conventional Fireplace InstallationIncluded with Mantel Accessory Assembling and Attaching Optional Brass TrimPlacing Hearth Base Accessory Against Wall BUILT-IN Fireplace Installation Mantel Clearances for Built-In InstallationInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Equipment Shutoff Valve to Heater Control Gas ConnectionChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections Place front log on top of the grate. Make sure the notches Installing Fireplace Screen Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Inspecting Burners Pilot Flame PatternOptional Blower Operation Main BurnerLogs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyMaintenance, For Visit Com Wiring Diagram SpecificationsReplacement Parts Service HintsIllustrated Parts Breakdown Parts List Not a field replaceable partIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Cabinet Mantel and Full Hearth Base Corner Hearth BaseHardwood Hearth Base Laminate Trim for Hearth or MantelReceiver and HAND-HELD Remote Control KIT GHRC/CGHRC Series WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Not ShownOwners Registration Form Tape 107172-01G Warranty Information