Desa EFS33NR, EFS33NRA, EFS33PR, EFS33PRA VSGF33NR, VSGF33NRA, VSGF33PR, VSGF33PRA

Page 3

SAFETY INFORMATION PRODUCT IDENTIFICATION

3

SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Lo- cate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bedroom or bathroom.

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, ver- miculite, or rock wool. Using these added items can cause soot- ing. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.To prevent the creation of soot, follow the instructions in Clean- ing and Maintenance, page 19.

8.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls or furniture.

9.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if enough fresh air is not available. See Air for Combustion and Ventila- tion, pages 4 through 6. If fireplace keeps shutting off, see Troubleshooting, pages 20 through 23.

10.Do not run fireplace

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this fireplace to cook food or burn paper or other objects.

12.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the fireplace and to replace any part of the control sys- tem and any gas control which has been under water.

13.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

14.Turn fireplace off and let cool before servicing. Only a quali- fied service person should service and repair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

16.To prevent performance problems in propane/LP units, do not use propane/LP fuel tanks of less than 100 lbs. capacity (pro- pane/LP units only).

17.Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

Rear Log

Rear Burner

Front Log

 

Middle

 

Log

Piezo Ignitor

 

Front Burner

Base

 

Optional Remote Control

Assembly

 

Figure 1 - Log Base Assembly (VSGF33NRA Shown)

Top Louver

Top Outer

Casing

Assembly

 

Fireplace

 

Hood

 

Firebox

 

Support

 

 

Optional

 

Blower

 

Assembly

 

(Not

 

Included)

Screen

 

Assembly

Bottom

 

Louver

Figure 2 - Fireplace (VSGF33NRA Shown)

Assembly

 

For morevisit www..com

107172-01G

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Log Base Assembly VSGF33NRA ShownAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeAssembling and Attaching Optional Brass Trim Installation ClearancesConventional Fireplace Installation Included with Mantel AccessoryPlacing Hearth Base Accessory Against Wall Mantel Clearances for Built-In Installation BUILT-IN Fireplace InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationGas Connection Connecting Equipment Shutoff Valve to Heater ControlPressure Testing gas Supply Piping system Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Place front log on top of the grate. Make sure the notches Installing Fireplace Screen For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Main Burner Inspecting BurnersPilot Flame Pattern Optional Blower OperationCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, For Visit Com Service Hints Wiring DiagramSpecifications Replacement PartsIllustrated Parts Breakdown Not a field replaceable part Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Laminate Trim for Hearth or Mantel Cabinet Mantel and Full Hearth BaseCorner Hearth Base Hardwood Hearth BaseNot Shown Receiver and HAND-HELD Remote Control KIT GHRC/CGHRC SeriesWALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2Owners Registration Form Tape 107172-01G Warranty Information