Desa EFS33NR, EFS33NRA, EFS33PR, EFS33PRA VSGF33NR, VSGF33NRA, VSGF33PR, VSGF33PRA

Page 17

OPERATING FIREPLACE

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Manual Lighting Procedure

Optional Remote Operation

17

OPERATING FIREPLACE

Continued

Pilot Burner

Ignitor

 

Ignitor

Electrode

Pilot Burner

Electrode

 

 

 

Figure 33 - Pilot (Natural)

Figure 34 - Pilot (Propane/LP)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to keep from draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

Turn control knob clockwise to the PILOT position.

Use remote control manual OFF button.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 16.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, page 16.

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased sepa- rately (see Accessories, pages 28 through 30). Follow instruc- tions included with the remote control.

Thermostat Control Operation

(Optional GHRCTA Series Only) The thermostat control set- ting on the remote control unit can be set to any comfort level between WARMER and COOLER. The burners will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

For wall thermostat operation, follow instruction supplied with thermostat accessory GWMT1. For wall switch operation fol- low instructions supplied with GWMS2.

NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instruc- tions on page 16.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 35). Note: The burn- ers may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

GHRC Series Operation:

2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.

GHRCTA Series Operation:

2b. Press the AUTO/ON/OFF button on the hand-held remote control (see Figure 36, page 18). The lights to the left of the button will show AUTO, ON, or OFF.

In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.

In the AUTO mode, the thermostat in the hand-held remote unit controls the room temperature. To increase the room temperature, press the top arrow of the TEMP button. To lower the room temperature, press the bottom arrow of the TEMP button. At higher settings the heater will run longer. IMPORTANT: This remote control has been specially en- gineered to take an air temperature sample every minute in the auto mode. It will not respond immediately to the temperature setting being turned up or down.

 

Flame Adjustment Knob

ON

 

 

 

OL

N

 

 

 

 

 

 

 

OFF

O

 

 

O

 

 

 

REMOTE

T

 

F

O

 

 

 

F

HI

 

LI P

 

Selector Switch in Remote Position

 

Control Knob in

(Optional Remote Control)

 

On Position

Figure 35 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

For morevisit www..com

107172-01G

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsProduct Identification Log Base Assembly VSGF33NRA ShownLocal Codes Product FeaturesUnpacking AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installing Hood InstallationCheck GAS Type Electrical HookupConventional Fireplace Installation Installation ClearancesIncluded with Mantel Accessory Assembling and Attaching Optional Brass TrimPlacing Hearth Base Accessory Against Wall Mantel Clearances for Built-In Installation BUILT-IN Fireplace InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationGas Connection Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections Place front log on top of the grate. Make sure the notches Installing Fireplace Screen Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Pilot Flame Pattern Inspecting BurnersOptional Blower Operation Main BurnerLogs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingMaintenance, For Visit Com Specifications Wiring DiagramReplacement Parts Service HintsIllustrated Parts Breakdown Not a field replaceable part Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Corner Hearth Base Cabinet Mantel and Full Hearth BaseHardwood Hearth Base Laminate Trim for Hearth or MantelWALL-MOUNT Thermostat Switch GWMT1 Receiver and HAND-HELD Remote Control KIT GHRC/CGHRC SeriesWALL-MOUNT ON/OFF Switch GWMS2 Not ShownOwners Registration Form Tape 107172-01G Warranty Information