Desa AND VM42 Mantel Clearances and Wall Details, M36B,H M42B,H, VM36B,H VM42B,H

Page 7

PRE-INSTALLATION PREPARATION

Mantel Clearances and Wall Details

7

PRE-INSTALLATION

PREPARATION

Continued

MANTEL CLEARANCES AND WALL DETAILS

A combustible mantle shelf maybe installed a maximum 12" (229mm) from the wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to the fire- place opening.

12"

Combustible

(229mm)

Materials

Header

6" (152mm)

TOP VIEW

Outer Surround

Combustible

Material May

Be Used

1 1/2" (38mm)

SAFE

ZONE

Max.

3" (76mm)

 

 

 

 

Max.

 

6" (152mm) Max.

A

Perpendicular

B Wall

A

 

 

M36(B,H)

M42(B,H)

B

Spacer

 

VM36(B,H)

VM42(B,H)

A

9" (229mm)

6" (152mm)

 

 

 

 

B

12" (305mm)

9" (229mm)

3" (76mm)

Figure 6 - Side Clearances - Top View (Cross Section)

1 1/2"

(38mm) Max.

 

M36(B,H)

M42(B,H)

 

VM36(B,H)

VM42(B,H)

A

14" (356mm)

15" (381mm)

B

8" (203mm)

9" (229mm)

 

 

 

Figure 5 - Mantel Clearances - Side View (Cross Section)

For more information, visit www.desatech.com

108795-01K

Image 7
Contents What to do if YOU Smell GAS For Your SafetyVent Decorative GAS Fireplace Natural GASSafety Information Table of ContentsUnpacking Before YOU Begin IntroductionM36B,H/VM36B,H M42B,H/VM42B,H Model Product SpecificationsSelecting Location PRE-INSTALLATION PreparationClearances M36B,H M42B,H VM36B,H VM42B,H Mantel Clearances and Wall DetailsM36B,H M42B,H VM36B,H VM42B,HFraming Installing Transition Pipe and Starter CollarTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingInstalling Receiver InstallationWall Switch Installation Optional Wireless HAND-HELD Remote Control InstallationGAS Line HOOK-UP Installing 9-Volt Battery in Hand-Held Remote Control UnitOvertighten Ember and PAN Material PlacementInstalling Logs 3 LOG Placement for M36/VM36 ModelsRest the lower part of log 5 on the log 4 and on LOG Placement for M42/VM42 ModelsCombustion AIR KIT Model AK4 Optional Installing Optional Glass Door AccessoryAppliance Enclosure Removing Glass Doors Opening Vent DamperTo Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Pilot AssemblyInspecting Burners Optional HAND-HELD Remote OperationReplacement Parts Cleaning Maintenance Technical ServiceWiring Diagram Service HintsObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Gas leak. See Warning statement at TopModels Illustrated Parts BreakdownVM42B,H Under Replacement Parts on page 20 of this manual Parts ListLogset for M36B, H/VM36B, H Models Logsets for ModelsLogset for M42B, H/VM42B, H Models Owners Registration Form Postage Required Accessories Warranty Information