Desa AND VM42 Inspecting Burners, Optional HAND-HELD Remote Operation, Pilot Assembly

Page 19

OPERATING FIREPLACE

Continued

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: The receiver and hand-held remote control kit must be purchased separately (see Accessories, page 29). Follow installa- tion instructions on pages 11 and 12 of this manual.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Slide the selector switch to the REMOTE position. Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the RE- MOTE or ON position when the pilot is not lit. This will drain the battery.

2.Press the control button on the hand-held remote to turn the burner on. Press the control button again to turn burner off (see Figure 41).

3.To Lock press both buttons on remote control until light stops flashing. Remote is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

4.To Unlock press both buttons together on remote control until light stops flashing. The remote is now unlocked.

Control Button

Turns Burners

On and Off

Figure 41 - On/Off Hand-Held Remote Control Unit GHRCB

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Press in and turn control knob clockwise Clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

Turn remote control wall switch to the OFF position.

OPERATING FIREPLACE

19

Optional Hand-Held Remote Operation

To Turn Off Gas to Appliance

 

INSPECTING BURNERS

 

Pilot Assembly

 

Burner Flame Pattern

 

 

 

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. The pilot is located on the back right hand side of the burner.

The height of the thermopile must be 3/8" to 1/2" above the pilot flame. The flame from the pilot burner must extend beyond the thermopile.

If your pilot assembly does not meet these requirements:

Turn the adjustment screw marked pilot clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 39, page 18). Do not remove the adjustment screw.

see Troubleshooting, pages 21 through 23

Thermopile

Pilot Burner

Ignitor

Figure 42 - Correct Pilot Flame Pattern

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flames should go up through the middle of logset. Flames should not "spill" to the edges of the pan or sides of the logset.

Figure 43 shows a typical flame pattern. If burner flame pattern differs from that described:

turn appliance off (see To Turn Off Gas to Appliance, column 1)

see Troubleshooting, pages 21 through 23

Figure 43 - Typical Flame Pattern

For more information, visit www.desatech.com

108795-01K

Image 19
Contents What to do if YOU Smell GAS For Your SafetyVent Decorative GAS Fireplace Natural GASSafety Information Table of ContentsUnpacking Before YOU Begin IntroductionM36B,H/VM36B,H M42B,H/VM42B,H Model Product SpecificationsSelecting Location PRE-INSTALLATION PreparationClearances M36B,H M42B,H VM36B,H VM42B,H Mantel Clearances and Wall DetailsM36B,H M42B,H VM36B,H VM42B,HFraming Installing Transition Pipe and Starter CollarTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingInstalling Receiver InstallationWall Switch Installation Optional Wireless HAND-HELD Remote Control InstallationGAS Line HOOK-UP Installing 9-Volt Battery in Hand-Held Remote Control UnitOvertighten Ember and PAN Material PlacementInstalling Logs 3 LOG Placement for M36/VM36 ModelsRest the lower part of log 5 on the log 4 and on LOG Placement for M42/VM42 ModelsCombustion AIR KIT Model AK4 Optional Installing Optional Glass Door AccessoryAppliance Enclosure Removing Glass Doors Opening Vent DamperTo Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Pilot AssemblyInspecting Burners Optional HAND-HELD Remote OperationReplacement Parts Cleaning Maintenance Technical ServiceWiring Diagram Service HintsObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Gas leak. See Warning statement at TopModels Illustrated Parts BreakdownVM42B,H Under Replacement Parts on page 20 of this manual Parts ListLogset for M36B, H/VM36B, H Models Logsets for ModelsLogset for M42B, H/VM42B, H Models Owners Registration Form Postage Required Accessories Warranty Information