Desa BHDV34NA, BHDV34PA Installing LOGS, Lava Rock and Glowing Embers, Installing Log No

Page 24

® BHDV34NA, PA

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

Continued

INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with fireplace.

Remove glass door. See Removing/Replacing Glass Door, page 22. Install logs according to the following instructions.

1.Place log #1 (back log) on top of grate. Make sure the notches in the bottom of the log fit over the grate (see Figure 50).

2.Rest log #2 (large front log) on the pins on the front part of the grate (see Figure 51).

3.Place log #3 (crossover log) onto the rear and front logs. Make sure it is seated properly into the notch on the front log and over the raised triangular portion of the rear log as shown in Figure 52.

4.Place log #4 (small log) onto the front left part of the grate making sure the notches fit over the prong of the grate. See Figure 53.

5.Place lava rock along sides and front of firebox bottom in areas that are vis- ible only. It is not necessary to use all of the lava rock provided.

NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner could cause performance problems.

6.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed section of the front burner and along the space between the burner and grate prongs (see Figure 54). This will create the glowing ember ap- pearance as the flame touches the em- ber material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided.

7.Replace the glass door. See Removing/ Replacing Glass Door, page 22.

WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken.

1

Figure 50 - Installing Log No. 1

2

3

Figure 52 - Installing Log No. 3

4

Figure 53 - Installing Log No. 4

Ember Material

Figure 54 - Placing Ember Material on Burner

Figure 51 - Installing Log No. 2

24

105981

Image 24
Contents For Your Safety For Your Safety What to do if YOU Smell GASNatural GAS Model BHDV34NA PROPANE/LP GAS Model BHDV34PA Safety Information DIRECT-VENT Fireplace NATURAL/PROPANE/LPProduct Features Product IdentificationLocal Codes Glossary TermsPRE-INSTALLATION Preparation Location and Space RequirementsClearances Framing and FinishingGeneral Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Rigid Venting Configuration Using Two 90 Elbows Vertical VentingVenting Fireplace Installation Installing Optional Blower AccessoryInstalling GA3700/DA3610T Blowers Check GAS TypeAs a freestanding unit with an ac Side ViewInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Fireplace Gas Connections Close manual shutoff valve see Fig- ureInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2Installing 9-Volt Alkaline Battery into Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitREMOVING/REPLACING Glass Door Installing Optional Brick Liner D8037A Installing Left Side Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoOperating Fireplace Operating Optional Blower Accessory Ghrc Series OperationGhrct Series Operation Pilot Assembly Inspecting BurnersOperating Optional GWMT1 Wall Mounted Thermostat Burner Flame PatternCleaning and Maintenance Glass DoorPilot and Burners Venting SystemTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveReplacement Parts Wiring DiagramTechnical Service Service HintsSpecifications BHDV34NA BHDV34PAAccessories Receiver and HAND-HELD Remote Control KIT Ghrc Series Duplex Outlet KITBrass Louver KIT Manual Blower KIT GA3700Illustrated Parts Breakdown BHDV34NA BHDV34PAParts List DIRECT-VENT Fireplace BHDV34NA BHDV34PAWarranty Information