Desa BHDV34NA REMOVING/REPLACING Glass Door, Installing 9-Volt Alkaline Battery into Receiver

Page 22

® BHDV34NA, PA

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES - GHRC AND GHRCT

NOTICE: Use only alkaline bat- teries (not included).

Installing 9-Volt Alkaline Battery into Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt al- kaline battery (not included) through the clip.

4.Attach the terminal wires to the battery.

5.Remove the wire that runs from TH to TPTH from the valve (see Figure 40, page 21).

6.Connect wires from receiver to TH and TPTH on the valve (see Figure 41, page 21).

7.Replace the switch bracket.

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 44 - Attaching Alkaline Battery to Receiver

Installing 9-Volt Battery in Hand- Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to a 9-volt alka- line battery (not included). Place bat- tery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

 

Battery

 

Terminal

Cover

Remote

 

Wires

 

Control Unit

9-Volt

 

 

Battery

 

 

 

 

Battery

 

 

Housing

Figure 45 - Installing Alkaline Battery in Hand-Held Remote Control Unit

REMOVING/REPLACING GLASS DOOR

You must remove glass door to install op- tional brick liners, logs, lava rock, and em- ber material.

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For re- placement part information see Replacement Parts, page 32.

1.Remove the upper louver panel by lift- ing upward and out (see Figure 46).

2.Remove the screws from the three tabs at the top of the glass door while hold- ing door securely keeping it from fall- ing forward.

3.Grasp door by both sides and ease it upward off of the lower bracket (see Figure 47).

4.To replace glass door, follow the above instructions in reverse.

Top Louver

Panel

Figure 46 - Removing Top Louver Panel

Screw

Glass Door

Assembly

Lower Bracket for

Glass Door Assembly

Figure 47 - Removing/Replacing Glass Door

22

105981

Image 22
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyNatural GAS Model BHDV34NA PROPANE/LP GAS Model BHDV34PA Safety Information DIRECT-VENT Fireplace NATURAL/PROPANE/LPLocal Codes Product FeaturesProduct Identification Glossary TermsClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingGeneral Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Rigid Venting Configuration Using Two 90 Elbows Vertical VentingVenting Installing GA3700/DA3610T Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypeAs a freestanding unit with an ac Side ViewInstalling GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas Connections Close manual shutoff valve see Fig- ureInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2Installing 9-Volt Battery in Hand- Held Remote Control Unit Installing 9-Volt Alkaline Battery into ReceiverREMOVING/REPLACING Glass Door Installing Optional Brick Liner D8037A Installing Left Side Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoOperating Fireplace Ghrc Series Operation Operating Optional Blower AccessoryGhrct Series Operation Operating Optional GWMT1 Wall Mounted Thermostat Pilot AssemblyInspecting Burners Burner Flame PatternPilot and Burners Cleaning and MaintenanceGlass Door Venting SystemTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveTechnical Service Replacement PartsWiring Diagram Service HintsSpecifications BHDV34NA BHDV34PAAccessories Brass Louver KIT Receiver and HAND-HELD Remote Control KIT Ghrc SeriesDuplex Outlet KIT Manual Blower KIT GA3700Illustrated Parts Breakdown BHDV34NA BHDV34PAParts List DIRECT-VENT Fireplace BHDV34NA BHDV34PAWarranty Information