OWNER’S MANUAL
FIREPLACE INSTALLATION
Continued
INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1
WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.
WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.
1.Open lower louver panel. The valve is attached to the underside of the firebox assembly.
2.Disconnect the wire that runs from TH to TPTH from the valve as shown in Figure 40.
3.Connect one terminal of 25 ft. wire for the wall thermostat to the TPTH termi- nal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 41. If wires are not connected as shown the thermostat will not work.
4.Route the 25 ft. wire through openings provided on the sides of the fireplace to a convenient location to mount your thermostat (no outside wall).
IMPORTANT: The wire may be short- ened but must not be lengthened.
Figure 40 - Disconnecting TH to TPTH Wire
The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air conditioning ducts.
5.Gently remove the cover of the ther- mostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.
6.Feed the electrical wires through the rectangular slots (from the back) on each side of the base (see Figure 42).
WARNING: Do not connect this thermostat to a power source. Electrical shock and/or fire haz- ard will occur.
7.Connect one bare wire end to each ter- minal (“W” and “R”) of the thermostat base (see Figure 43).
8.Install the base to the wall with screws provided with thermostat.
9.Move the temperature adjustment back and forth to insure the bimetal is free from restrictions.
10.Replace the cover onto the base. (Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.)
11.Set the temperature adjustment to the desired setting.
This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary.
To Wall Optional
Remote Accessory
t
Figure 41 - Control Valve Terminals
Feed wires through rectangular slots
Figure 42 - Back View of Thermostat Base
| Terminal “W” |
W |
R
Terminal “R”
Figure 43 - Thermostat Base Terminals “W” and “R”
INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2
1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 41. If wires are not connected as shown the switch will not work.
2.Route the 25 ft. wire through openings provided on the sides of the fireplace to a convenient location to mount your switch.
3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.
4.Install the wall switch and cover in the wall.
Continued
105981 | 21 |