® BHDV34NA, PA
DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)
PRE-INSTALLATION PREPARATION
LOCATION AND SPACE REQUIREMENTS
Determine the safest and most efficient loca- tion for your Vanguard
When deciding the location of your fire- place, follow these rules:
1.Do not connect this fireplace to a chim- ney flue serving a separate
2.Due to high temperatures, do not lo- cate this fireplace in high traffic areas or near furniture or draperies.
3.Proper clearances must be maintained.
4.If your fireplace is to be installed di- rectly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.
Flush with a wall
Through exterior wall enclosed in a chase
Corner installation
Figure 2 - Common Fireplace Locations
|
|
|
| RW |
|
|
| |
| D |
|
|
|
|
| ||
|
|
|
| FW |
| |||
|
|
|
|
| ||||
|
|
|
|
| ||||
Fireplace size |
| D x FW x RW | ||||||
34" |
|
| 18 1/2" | 34 3/8" | 14" |
CLEARANCES
Minimum clearances to combustibles for the fireplace are as follows:
Back, and sides | 0"/mm |
Perpendicular walls | 6" (152mm) |
Floor | 0"/mm |
Ceiling to louver opening | 42" (1067mm) |
Front | 36" (914mm) |
Top of Standoffs | 0"/mm |
See General Venting on page 5 for specific venting clearances.
FRAMING AND FINISHING
Figures 4 and 5 show typical framing of this fireplace. Figure 6 on page 5 shows framing for corner installation. All minimum clear- ances must be met. Do not install fireplace directly on carpeting, vinyl tile, or any com- bustible material other than wood. The fire- place must set on a metal or wood panel extending the full width and depth of the fireplace.
See Accessories on pages 34 and 35 for mantel kits available for this fireplace. If you are using a separate combustible mantel piece, refer to Figure 7 on page 5 for proper instal- lation height. You can install noncombustible mantels at any height above the fireplace. Note:Noncombustible mantels may discolor!
341/4"
343/4"
Must maintain a minimum 1" clearance to combustibles
34"
20"
5/8" for drywall facing
Figure 5 - Framing Clearances for Typical Fireplace Installation
20" Vertical Termination
19" Horizontal Termination
Figure 3 - Fireplace Bottom Dimensions
Figure 4 - Framing Clearances for Installation Against an Exterior Wall
4 | 105981 |